Common use of Protocol Procedure Clause in Contracts

Protocol Procedure. It shall be the responsibility of the Generator as regards the correctness of design, workmanship of equipment and its procurement, installation, testing, maintenance and operation of the their generation system. In any event, MSEDCL shall not be responsible for any damage caused to the generating set or equipment or/and generation system on account of any mistake or defect in the design, procurement, installation, testing, maintenance & operation of generation system of Generator. The Generator shall make all arrangements for paralleling the set/s with the MSEDCL’s grid at their cost at the point of supply, in consultation with and to the satisfaction of the MSEDCL’s officers, that is subject to the approval of the Electrical Inspector. However, it shall be the responsibility of the Generator to avoid back feeding of the supply to their generating unit. The Generator shall run the generating set and generation system unit as a part of integrated grid system. The Generator may, if found necessary, with prior permission of the MSEDCL change or arrange to modify the MSEDCL’s supply system or infrastructure for the purpose of auxiliary power requirement without causing any damages to any of the equipment or installation of the supply arrangements of the MSEDCL and the cost of such modification shall be borne by the Generator. The Generator shall pay the damages to the MSEDCL, if any, caused to the supply system / arrangement of the MSEDCL. The SE (O & M) Circle, MSEDCL ………….. shall be the nodal officer for effecting all techno-commercial arrangement and payment thereof. The Generator shall also keep liaison with the X.X., X & X Xxxxxx, , XX (XXX), XXXXXX, Xxxxxx and the Chief Engineer, Load Dispatch Centre, Kalwa during the period of generation. During the period this Agreement is in force, the Generator shall intimate one month in advance to the S.E., O&M Circle, ……….. and the chief Engineer, X.X. Centre, Kalwa in Annexure-A, the date of commencement of generation and also arrange for testing and commissioning of the protection system well in advance. If requested by the Generator, the MSEDCL shall extend the assistance for the purpose of testing, subject to condition that the Generator shall pay the charges for such assistance to the MSEDCL as would be notified or indicated by the concerned testing division of the MSEDCL. The Generator shall furnish a monthly schedule of program of the proposed supply of electricity to the MSEDCL, indicating the total quantum of electricity etc., in the last week of every month. The Generator shall submit Monthly Invoice in the form annexed as Annexure-B to this Agreement to S.E. (O&M), MSEDCL, ……… Circle with a copy for information to C.E.(Power Purchase), MSEDCL, Mumbai. The Generator shall maintain log book and submit daily generation report in the form annexed as Annexure - C to this Agreement to Chief Engineer Load Dispatch, Kalwa, S.E., O&M Circle, irrespective of energy generation or no generation. The Generator shall maintain a monthly tripping report and the reason thereof in the form annexed as Annexure -D to this Agreement. Inspection of premises of the Generator by any MSEDCL/MSETCL’s official without prior permission or intimation to the Generator shall be allowed. Continuity of Services – Notwithstanding anything contained herein above, the Generator shall not be entitled to and the MSEDCL shall not be liable to pay any compensation on account of non drawl of energy due to defect in the grid or Force Majeure conditions specified hereinafter or any other circumstances beyond the control of the MSEDCL. The MSEDCL shall take all reasonable steps to minimize the number and duration of interruptions, curtailments or reduction.

Appears in 4 contracts

Samples: Power Purchase Agreement, Power Purchase Agreement, Power Purchase Agreement

AutoNDA by SimpleDocs

Protocol Procedure. It shall be the responsibility of the Generator as regards the correctness of design, workmanship of equipment and its procurement, installation, testing, maintenance and operation of the their generation system. In any event, MSEDCL shall not be responsible for any damage caused to the generating set or equipment or/and generation system on account of any mistake or defect in the design, procurement, installation, testing, maintenance & operation of generation system of Generator. The Generator shall make all arrangements for paralleling the set/s with the MSEDCL’s grid at their cost at the point of supply, in consultation with and to the satisfaction of the MSEDCL’s officers, that is subject to the approval of the Electrical Inspector. However, it shall be the responsibility of the Generator to avoid back feeding of the supply to their generating unit. The Generator shall run the generating set and generation system unit as a part of integrated grid system. The Generator may, if found necessary, with prior permission of the MSEDCL change or arrange to modify the MSEDCL’s supply system or infrastructure for the purpose of auxiliary power requirement without causing any damages to any of the equipment or installation of the supply arrangements of the MSEDCL and the cost of such modification shall be borne by the Generator. The Generator shall pay the damages to the MSEDCL, if any, caused to the supply system / arrangement of the MSEDCL. The SE (O & M) Circle, MSEDCL ………….. shall be the nodal officer for effecting all techno-commercial arrangement and payment thereofarrangement. The Generator shall also keep liaison with the X.X., X & X Xxxxxx, , XX (XXX), XXXXXX, Xxxxxx and the Chief Engineer, Load Dispatch Centre, Kalwa during the period of generation. During the period this Agreement is in force, the Generator shall intimate one month in advance to the S.E., O&M Circle, ……….. and the chief Engineer, X.X. Centre, Kalwa in Annexure-A, the date of commencement of generation and also arrange for testing and commissioning of the protection system well in advance. If requested by the Generator, the MSEDCL shall extend the assistance for the purpose of testing, subject to condition that the Generator shall pay the charges for such assistance to the MSEDCL as would be notified or indicated by the concerned testing division of the MSEDCL. The Generator shall furnish a monthly schedule of program of the proposed supply of electricity to the MSEDCL, indicating the total quantum of electricity etc., in the last week of every month. The Generator shall submit Monthly Invoice in the form annexed as Annexure-B to this Agreement to S.E. (O&M), MSEDCL, ……… Circle with a copy for information to C.E.(Power PurchaseC.E.(Renewable Energy), MSEDCL, Mumbai. The Generator shall maintain log book and submit daily generation report in the form annexed as Annexure - C to this Agreement to Chief Engineer Load Dispatch, Kalwa, S.E., O&M Circle, irrespective of energy generation or no generation. The Generator shall maintain a monthly tripping report and the reason thereof in the form annexed as Annexure -D to this Agreement. Inspection of premises of the Generator by any MSEDCL/MSETCL’s official without prior permission or intimation to the Generator shall be allowed. Continuity of Services – Notwithstanding anything contained herein above, the Generator shall not be entitled to and the MSEDCL shall not be liable to pay any compensation on account of non drawl of energy due to defect in the grid or Force Majeure conditions specified hereinafter or any other circumstances beyond the control of the MSEDCL. The MSEDCL shall take all reasonable steps to minimize the number and duration of interruptions, curtailments or reduction.

Appears in 2 contracts

Samples: Power Purchase Agreement, Power Purchase Agreement

Protocol Procedure. It shall be the responsibility of the Generator as regards the correctness of design, workmanship of equipment and its procurement, installation, testing, maintenance and operation of the their generation system. In any event, MSEDCL shall not be responsible for any damage caused to the generating set or equipment or/and generation system on account of any mistake or defect in the design, procurement, installation, testing, maintenance & operation of generation system of Generator. The Generator shall make all arrangements for paralleling the set/s with the MSEDCL’s grid at their cost at the point of supply, in consultation with and to the satisfaction of the MSEDCL’s officers, that is subject to the approval of the Electrical Inspector. However, it shall be the responsibility of the Generator to avoid back feeding of the supply to their generating unit. The Generator shall run the generating set and generation system unit as a part of integrated grid system. The Generator may, if found necessary, with prior permission of the MSEDCL change or arrange to modify the MSEDCL’s supply system or infrastructure for the purpose of auxiliary power requirement without causing any damages to any of the equipment or installation of the supply arrangements of the MSEDCL and the cost of such modification shall be borne by the Generator. The Generator shall pay the damages to the MSEDCL, if any, caused to the supply system / arrangement of the MSEDCL. The SE (O & M) Circle, MSEDCL ………….. shall be the nodal officer for effecting all techno-commercial arrangement and payment thereofarrangement. The Generator shall also keep liaison with the X.X., X & X Xxxxxx, , XX (XXX), XXXXXX, Xxxxxx and the Chief Engineer, Load Dispatch Centre, Kalwa during the period of generation. During the period this Agreement is in force, the Generator shall intimate one month in advance to the S.E., O&M Circle, ……….. and the chief Engineer, X.X. Centre, Kalwa in Annexure-A, the date of commencement of generation and also arrange for testing and commissioning of the protection system well in advance. If requested by the Generator, the MSEDCL shall extend the assistance for the purpose of testing, subject to condition that the Generator shall pay the charges for such assistance to the MSEDCL as would be notified or indicated by the concerned testing division of the MSEDCL. The Generator shall furnish a monthly schedule of program of the proposed supply of electricity to the MSEDCL, indicating the total quantum of electricity etc., in the last week of every month. The Generator shall submit Monthly Invoice in the form annexed as Annexure-B to this Agreement to S.E. (O&M), MSEDCL, ……… Circle with a copy for information to C.E.(Power PurchaseC.E.(Renewable Energy), MSEDCL, Mumbai. The Generator shall maintain log book and submit daily generation report in the form annexed as Annexure - C to this Agreement to Chief Engineer Load Dispatch, Kalwa, S.E., O&M Circle, irrespective of energy generation or no generation. The Generator shall maintain a monthly tripping report and the reason thereof in the form annexed as Annexure -D to this Agreement. Inspection of premises of the Generator by any MSEDCL/MSETCL’s official without prior permission or intimation to the Generator shall be allowed. Continuity of Services – Notwithstanding anything contained herein above, the Generator shall not be entitled to and the MSEDCL shall not be liable to pay any compensation on account of non drawl of energy due to defect in the grid or Force Majeure conditions specified hereinafter or any other circumstances beyond the control of the MSEDCL. The MSEDCL shall take all reasonable steps to minimize the number and duration of interruptions, curtailments or reduction.prior

Appears in 1 contract

Samples: Power Purchase Agreement

Protocol Procedure. It shall be the responsibility of the Generator as regards the correctness of design, workmanship of equipment and its procurement, installation, testing, maintenance and operation of the their generation system. In any event, MSEDCL shall not be responsible for any damage caused to the generating set or equipment or/and generation system on account of any mistake or defect in the design, procurement, installation, testing, maintenance & operation of generation system of Generator. The Generator shall make all arrangements for paralleling the set/s with the MSEDCL’s grid at their cost at the point of supply, in consultation with and to the satisfaction of the MSEDCL’s officers, that is subject to the approval of the Electrical Inspector. However, it shall be the responsibility of the Generator to avoid back feeding of the supply to their generating unit. The Generator shall run the generating set and generation system unit as a part of integrated grid system. The Generator may, if found necessary, with prior permission of the MSEDCL change or arrange to modify the MSEDCL’s supply system or infrastructure for the purpose of auxiliary power requirement without causing any damages to any of the equipment or installation of the supply arrangements of the MSEDCL and the cost of such modification shall be borne by the Generator. The Generator shall pay the damages to the MSEDCL, if any, caused to the supply system / arrangement of the MSEDCL. The SE (O & M) Circle, MSEDCL ………….. shall be the nodal officer for effecting all techno-commercial arrangement and payment thereof. The Generator shall also keep liaison with the X.X., X & X Xxxxxx, , XX CE (XXXSTU), XXXXXXMSETCL, Xxxxxx Mumbai and the Chief Engineer, Load Dispatch Centre, Kalwa during the period of generation. During the period this Agreement is in force, the Generator shall intimate one month in advance to the S.E., O&M Circle, ……….. and the chief Engineer, X.X. Centre, Kalwa in Annexure-A, the date of commencement of generation and also arrange for testing and commissioning of the protection system well in advance. If requested by the Generator, the MSEDCL shall extend the assistance for the purpose of testing, subject to condition that the Generator shall pay the charges for such assistance to the MSEDCL as would be notified or indicated by the concerned testing division of the MSEDCL. The Generator shall furnish a monthly schedule of program of the proposed supply of electricity to the MSEDCL, indicating the total quantum of electricity etc., in the last week of every month. The Generator shall submit Monthly Invoice in the form annexed as Annexure-B to this Agreement to S.E. (O&M), MSEDCL, ……… Circle with a copy for information to C.E.(Power Purchase), MSEDCL, Mumbai. The Generator shall maintain log book and submit daily generation report in the form annexed as Annexure - C to this Agreement to Chief Engineer Load Dispatch, Kalwa, S.E., O&M Circle, irrespective of energy generation or no generation. The Generator shall maintain a monthly tripping report and the reason thereof in the form annexed as Annexure -D to this Agreement. Inspection of premises of the Generator by any MSEDCL/MSETCL’s official without prior permission or intimation to the Generator shall be allowed. Continuity of Services – Notwithstanding anything contained herein above, the Generator shall not be entitled to and the MSEDCL shall not be liable to pay any compensation on account of non drawl of energy due to defect in the grid or Force Majeure conditions specified hereinafter or any other circumstances beyond the control of the MSEDCL. The MSEDCL shall take all reasonable steps to minimize the number and duration of interruptions, curtailments or reduction.

Appears in 1 contract

Samples: Power Purchase Agreement

AutoNDA by SimpleDocs

Protocol Procedure. It shall be the responsibility of the Generator as regards the correctness of design, workmanship of equipment and its procurement, installation, testing, maintenance and operation of the their generation system. In any event, MSEDCL shall not be responsible for any damage caused to the generating set or equipment or/and generation system on account of any mistake or defect in the design, procurement, installation, testing, maintenance & operation of generation system of Generator. The Generator shall make all arrangements for paralleling the set/s with the MSEDCL’s grid at their cost at the point of supply, in consultation with and to the satisfaction of the MSEDCL’s officers, that is subject to the approval of the Electrical Inspector. However, it shall be the responsibility of the Generator to avoid back feeding of the supply to their generating unit. The Generator shall run the generating set and generation system unit as a part of integrated grid system. The Generator may, if found necessary, with prior permission of the MSEDCL change or arrange to modify the MSEDCL’s supply system or infrastructure for the purpose of auxiliary power requirement without causing any damages to any of the equipment or installation of the supply arrangements of the MSEDCL and the cost of such modification shall be borne by the Generator. The Generator shall pay the damages to the MSEDCL, if any, caused to the supply system / arrangement of the MSEDCL. The SE (O & M) Circle, MSEDCL ………….. shall be the nodal officer for effecting all techno-commercial arrangement and payment thereof. The Generator shall also keep liaison with the X.X., X & X Xxxxxx, ……………., XX (XXX), XXXXXX, Xxxxxx and the Chief Engineer, Load Dispatch Centre, Kalwa during the period of generation. During the period this Agreement is in force, the Generator shall intimate one month in advance to the S.E., O&M Circle, ……….. and the chief Engineer, X.X. Centre, Kalwa in Annexure-A, the date of commencement of generation and also arrange for testing and commissioning of the protection system well in advance. If requested by the Generator, the MSEDCL shall extend the assistance for the purpose of testing, subject to condition that the Generator shall pay the charges for such assistance to the MSEDCL as would be notified or indicated by the concerned testing division of the MSEDCL. The Generator shall furnish a monthly schedule of program of the proposed supply of electricity to the MSEDCL, indicating the total quantum of electricity etc., in the last week of every month. The Generator shall submit Monthly Invoice in the form annexed as Annexure-B to this Agreement to S.E. (O&M), MSEDCL, ……… Circle with a copy for information to C.E.(Power Purchase), MSEDCL, Mumbai. The Generator shall maintain log book and submit daily generation report in the form annexed as Annexure - C to this Agreement to Chief Engineer Load Dispatch, Kalwa, S.E., O&M Circle, irrespective of energy generation or no generation. The Generator shall maintain a monthly tripping report and the reason thereof in the form annexed as Annexure -D to this Agreement. Inspection of premises of the Generator by any MSEDCL/MSETCL’s official without prior permission or intimation to the Generator shall be allowed. Continuity of Services – Notwithstanding anything contained herein above, the Generator shall not be entitled to and the MSEDCL shall not be liable to pay any compensation on account of non non- drawl of energy due to defect in the grid or Force Majeure conditions specified hereinafter or any other circumstances beyond the control of the MSEDCL. The MSEDCL shall take all reasonable steps to minimize the number and duration of interruptions, curtailments or reduction.

Appears in 1 contract

Samples: Power Purchase Agreement

Time is Money Join Law Insider Premium to draft better contracts faster.