Provisional Certificate Sample Clauses

Provisional Certificate. 12.2.1 Subject to the provisions of Clause 12.2.5, upon completion of all Works forming part of the Project Highway, save and except the Works for which Time Extension has been granted under Clause 10.5, the Authority’s Engineer shall, at the request of the Contractor, issue a provisional certificate of completion substantially in the form set forth in Schedule-L (the “Provisional Certificate”) if the Tests for and in respect of the completed Works are successful. The Provisional Certificate shall have appended thereto a list of outstanding items of work (the “Punch List”) that need to be completed in accordance with the provisions of this Agreement. The Contractor undertakes to complete the minor outstanding items of works in respect of those Sections of the Project Highway for which the Provisional Certificate has been issued, within a period of 30 (thirty) days of the date of Provisional Certificate, and those parts of the Works in respect of which Time Extension has been granted, within the extended period thereof. For the avoidance of doubt, the Parties agree that the Punch List shall include all Works for which Time Extension has been granted and shall also include any minor outstanding items of work forming part of the completed Sections if such works do not materially affect the use of the completed Sections for their intended purpose. The Parties further agree that Provisional Certificate shall not be issued if the completed Works can not be safely and reliably placed in service of the Users thereof. 12.2.2 Upon issue of Provisional Certificate, the provisions of Articles 14 and 17 shall apply to the completed parts of the Project Highway and the property and ownership of all such completed Works shall vest in the Authority. 12.2.3 If the Authority’s Engineer determines that the Project Highway or any completed part thereof does not conform to the provisions of this Agreement and cannot be safely and reliably placed in operation, it shall forthwith make a report in this behalf and send copies thereof to the Authority and the Contractor and withhold issuance of the Provisional Certificate until the Defects or deficiencies are rectified by the Contractor and Tests are successful in accordance with this Article 12. 12.2.4 Notwithstanding anything to the contrary contained in Clause 12.2.3, the Authority may, at any time after receiving a report from the Authority’s Engineer under that Xxxxxx, direct the Authority’s Engineer to issue a Provisional Cer...
AutoNDA by SimpleDocs
Provisional Certificate. 14.3.1 The Independent Engineer may, at the request of the Concessionaire, issue a provisional certificate of completion substantially in the form set forth in Schedule-J (the "Provisional Certificate") if the Tests are successful and the Bus Terminal can be safely and reliably placed in commercial operation though certain works or things forming part thereof are outstanding and not yet complete. In such an event, the Provisional Certificate shall have appended thereto a list of outstanding items signed jointly by the Independent Engineer and the Concessionaire (the "Punch List"); provided that the Independent Engineer shall not withhold the Provisional Certificate for reason of any work remaining incomplete if the delay in completion thereof is attributable to the Authority. 14.3.2 The Parties hereto expressly agree that a Provisional Certificate under this Clause 14.3 may, upon request of the Concessionaire to this effect, be issued for operating part of the Bus Terminal, if at least 75% (seventy five per cent) works of the Bus Terminal has been completed. Upon issue of such Provisional Certificate, the provisions of Article 15 shall apply to such completed part.
Provisional Certificate. 14.3.1 The Independent Engineer may, at the request of the Concessionaire, issue a provisional certificate of completion substantially in the form set forth in Schedule-J (the "Provisional Certificate") if the Tests are successful and the Bus Terminal and/ or Commercial Complex can be safely and reliably placed in commercial operation though certain works or things forming part are outstanding and not yet complete. In such an event, the Provisional Certificate shall have appended thereto a list of outstanding items signed jointly by the Independent Engineer and the Concessionaire (the "Punch List"); provided that the Independent Engineer shall not withhold the Provisional Certificate for reason of any work remaining incomplete if the delay in completion thereof is attributable to the Concessioning Authority. 14.3.2 The Parties hereto expressly agree that a Provisional Certificate under this Clause 14.3 may, upon request of the Concessionaire to this effect, be issued for operating part of the Project, if at least 95% of Bus Terminal and mandatory Commercial Complex respectively has been completed. Upon issue of such Provisional Certificate, the provisions of Article 15 shall apply to such completed part.
Provisional Certificate. The Independent Engineer may, at the request of the Concessionaire, issue a provisional certificate of completion substantially in the form set forth in Schedule-J (the “Provisional Certificate”) if the Tests are successful and the Port can be safely and reliably placed in commercial operation though certain works or things forming part thereof are outstanding and not yet complete. In such an event, the Provisional Certificate shall have appended thereto a list of outstanding items signed jointly by the Independent Engineer and the Concessionaire (the “Punch List”); provided that the Independent Engineer shall not withhold the Provisional Certificate for reason of any work remaining incomplete if the delay in completion thereof is attributable to the Authority.
Provisional Certificate. If the Project is complete and the Concessionaire certifies in writing that the Tests are successful and all the facilities required for rendering Hospitality Services, can be safely and reliably placed in commercial operation, even though certain works or things forming part thereof which do not affect the use and safety of the Project, or any part of the Project, for their intended purpose, are outstanding and are to be completed (the “Punch List”), the Independent Expert may, at the request of the Concessionaire, issue a provisional completion certificate, specifying the details of the Punch List which the Concessionaire shall be required to complete before issuance of a Completion Certificate (the “Provisional Certificate”). Upon issuance of such Provisional Certificate the Concessionaire shall be entitled to demand and collect the Revenue for rendering such Hospitality Services in accordance with this Agreement.
Provisional Certificate. Sewerage
Provisional Certificate. If the Project or any part thereof as specified in Article 16, as the case maybe, is complete and the Concessionaire certifies in writing that the Tests are successful and the Development Works or part thereof as specified in Article 16, as the case maybe, can be safely and reliably placed in operation, even though certain works or things forming part thereof which do not affect the use and safety of the Development Works, or any part of the Development Works, for their intended purpose, are outstanding and are to be completed (the “Punch List”), the Independent Engineer may, at the request of the Concessionaire, issue a provisional completion certificate, specifying the details of the Punch List which the Concessionaire shall be required to complete before issuance of a Completion Certificate (the “Provisional Certificate”).
AutoNDA by SimpleDocs
Provisional Certificate. The Independent Engineer and the Monitoring Agency may, at the request of the Concessionaire, certify in writing if the Completion Tests are successful and all the facilities required for rendering Diagnostic Services (as contemplated in Phase I) and OPD Services, can be safely and reliably placed in commercial operation. Upon such certification the Concessionaire shall be entitled to demand and collect the Fee for rendering such Diagnostic Services and OPD Services in accordance with this Agreement. For the avoidance of the doubt the Parties agree that notwithstanding anything to the contrary contained in this Clause 14.3, the obligations contained in Clause 12.4 shall continue to be binding on the Concessionaire.
Provisional Certificate. 12.2.1 Upon completion of Tests, the Authority Engineer shall satisfy itself that the Tests have been successful and the Project is fit for opening / commissioning. A list of outstandingbut non-critical/non-safety items(called the “Punch List”),duly signed jointly by the Authority Engineer and the
Provisional Certificate. 12.2.1 Upon completion of Tests, the Authority’s Engineer shall satisfy itself that the Tests have been successful and the Railway Project is fit for opening to traffic. Upon such determination, the Authority’s Engineer shall issue to the Contractor and the Authority a certificate substantially in the form set forth in Schedule-K (the “Provisional Certificate”). The Authority’s Engineer may issue a Provisional Certificate even if certain works forming part of the Railway Project are not yet completed and in such an event, the Provisional Certificate shall have appended thereto a list of outstanding items signed jointly by the Authority’s Engineer and the Contractor (the “Punch List”). For the avoidance of doubt and by way of illustration, the Punch List may include [fencing, tree plantation, rest areas, ***]. 12.2.2 Upon issuance of the Provisional Certificate, the Authority’s Engineer shall forward to the Authority (i) copies of all Test data including Test results, and
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!