Ramp up of Despatch Sample Clauses

Ramp up of Despatch. In the event the Utility Despatches less than 2% (two per cent) of Contracted Capacity at any time and requires ramping up of generation thereafter, it shall allow a period of 4 (four) hours to the Aggregator for reaching Availability equal to the Contracted Capacity. For the avoidance of doubt, the Parties agree that in the event the Aggregator fails to reach such Availability within 4 (four) hours, the shortfall thereof shall be deemed to be Mis-declaration under the provisions of Clause 11.
AutoNDA by SimpleDocs
Ramp up of Despatch. In the event the Aggregator Despatches less than 2% (two per cent) of Contracted Capacity at any time and requires ramping up of generation thereafter, it shall allow a period of 4 (four) hours to the Supplier for reaching Availability equal to the Contracted Capacity. For the avoidance of doubt, the Parties agree that in the event the Supplier fails to reach such Availability within 4 (four) hours, the shortfall thereof shall be deemed to be Mis-declaration under the provisions of Clause 11.4.4. The Parties further agree that the liability of the Aggregator hereunder shall at all times be reckoned with reference to the Contracted Capacity.
Ramp up of Despatch. In the event the Utility Despatches less than 2% (two per cent) of Contracted Capacity at any time and requires ramping up of generation thereafter, it shall allow a period of 4 (four)33hours to the Supplier for reaching Availability equal to the Contracted Capacity. For the avoidance of doubt, the Parties agree that in the event the Supplier fails to reach such Availability within [4 (four)] hours, the shortfall thereof shall be deemed to be Mis-declaration under the provisions of Clause 11.5.5. The Parties further agree that the liability of the Utility hereunder shall at all times be reckoned with reference to the Contracted Capacity.
Ramp up of Despatch. In the event GRIDCO Despatches less than 2% (two per cent) of Contracted Capacity at any time and requires ramping up of generation thereafter, it shall allow a period of 4 (four) hours to the Supplier for reaching Availability equal to the Contracted Capacity. For the avoidance of doubt, the Parties agree that in the event the Supplier fails to reach such Availability within 4 (four) hours, the shortfall thereof shall be deemed to be Mis- declaration under the provisions of Clause 11.5.5. The Parties further agree that the liability of GRIDCO hereunder shall at all times be reckoned with reference to the Contracted Capacity.
Ramp up of Despatch. In the event MCGM, at any time, requires ramping up of generation, it shall allow a period of 5 minutes to the Concessionaire for reaching Availability equal to the Contracted Capacity. For the avoidance of doubt, the Parties agree that in the event the Concessionaire fails to reach such Availability within 5 minutes, the shortfall thereof shall be deemed to be Mis-declaration under the provisions of Clause 11.2.4. The Parties further agree that the liability of MCGM hereunder shall at all times be reckoned with reference to the Contracted Capacity.
Ramp up of Despatch. In the event NMMC, at any time, requires ramping up of generation of the Hydro Electric Power Plant, it shall allow a period defined in the detailed project report (approved and vetted by MEDA or third party auditor) to the Concessionaire for reaching Availability equal to the Contracted Capacity. For the avoidance of doubt, the Parties agree that in the event the Concessionaire fails to reach such Availability within the stipulated time period, the shortfall thereof shall be deemed to be Mis- declaration under the provision of Article