Requirements for FFR provision Sample Clauses

Requirements for FFR provision. Figure 3The following figure shows a sequential diagram for the activation of FFR, support duration, deactivation, buffer time and recovery period.
AutoNDA by SimpleDocs
Requirements for FFR provision. Figure 3 The following figure shows a sequential diagram for the activation of FFR, support duration, deactivation, buffer time and recovery period. Figure 3: Sequential diagram for the activation of FFR The following requirements apply: - The activation instant is at time equal to zero (0); - Different combinations of frequency activation level and full activation times are allowed: The maximum time for full activation is 0.70 s (for the activation level 49.5 Hz), 1.00 s (for the activation level 49.6 Hz), and 1.30 s (for the activation level 49.7 Hz); - Different minimum support duration is allowed: 5.0 s (for short support duration) and 30 s (for long support duration); The prequalified FFR capacity is the minimum support power in MW from the providing entity, within the time slot of the support duration. The maximum acceptable over-delivery is 20% of the prequalified FFR capacity. However, the reserve connecting TSO may allow up to 35% over-delivery upon request, depending on the national procurement process. There is no limitation in the rate of deactivation for the long support duration FFR; the deactivation can be stepwise. For the short support duration FFR, the rate of deactivation is limited to maximum 20% of the prequalified FFR capacity per second, as an average over any integration time of one second, and with no single step larger than 20%. The FFR providing entity must be ready for a new FFR activation cycle within 15 minutes after the activation instant. There is no requirement on the shape of recovery, it may be stepwise. However, the recovery must not exceed 25% of the prequalified FFR capacity and must not start before a time corresponding to the activation time, plus the support duration, plus the deactivation time, plus 10 seconds has elapsed from the activation instant. 13.4.2

Related to Requirements for FFR provision

  • Forecasting Requirements for Trunk Provisioning Within ninety (90) days of executing this Agreement, Reconex shall provide Verizon a two (2) year traffic forecast. This initial forecast will provide the amount of traffic to be delivered to and from Verizon over each of the Local Interconnection Trunk groups over the next eight (8) quarters. The forecast shall be updated and provided to Verizon on an as-needed basis but no less frequently than semiannually. All forecasts shall comply with the Verizon CLEC Interconnection Trunking Forecast Guide and shall include, at a minimum, Access Carrier Terminal Location (“ACTL”), traffic type (Local Traffic/Toll Traffic, Operator Services, 911, etc.), code (identifies trunk group), A location/Z location (CLLI codes for Reconex-IPs and Verizon-IPs), interface type (e.g., DS1), and trunks in service each year (cumulative).

  • Requirements for Protection In compliance with NPCC requirements and Good Utility Practice, Developer shall provide, install, own, and maintain relays, circuit breakers and all other devices necessary to remove any fault contribution of the Large Generating Facility to any short circuit occurring on the New York State Transmission System not otherwise isolated by Connecting Transmission Owner’s equipment, such that the removal of the fault contribution shall be coordinated with the protective requirements of the New York State Transmission System. Such protective equipment shall include, without limitation, a disconnecting device or switch with load- interrupting capability located between the Large Generating Facility and the New York State Transmission System at a site selected upon mutual agreement (not to be unreasonably withheld, conditioned or delayed) of the Developer and Connecting Transmission Owner. Developer shall be responsible for protection of the Large Generating Facility and Developer’s other equipment from such conditions as negative sequence currents, over- or under-frequency, sudden load rejection, over- or under-voltage, and generator loss-of-field. Developer shall be solely responsible to disconnect the Large Generating Facility and Developer’s other equipment if conditions on the New York State Transmission System could adversely affect the Large Generating Facility.

  • Certain State Law Requirements for Contracts The contents of this Section are required by Texas Law and are included by County regardless of content.

  • BUY AMERICAN PROVISIONS COMPLIANCE To the extent applicable, Supplier must comply with all applicable provisions of the Buy American Act. Purchases made in accordance with the Buy American Act must follow the applicable procurement rules calling for free and open competition.

  • EEO Provisions During the performance of this Contract the Contractor agrees as follows: (1) The Contractor shall not discriminate against any employee or applicant for employment because of race, color, religion, sex, national origin, political affiliation or belief, age, or handicap. The Contractor shall take affirmative action to insure that applicants are employed and that employees are treated equally during employment, without regard to race, color, religion, sex, national origin, political affiliation or belief, age, or handicap. Such action shall include but not be limited to the following: employment, upgrading, demotion, transfer, recruitment or advertising, layoff or termination, rates of pay or other forms of compensation, and selection for training, including apprenticeship. The Contractor shall post in conspicuous places, available to employees and applicants for employment, notices setting forth these EEO provisions. (2) The Contractor shall in all solicitations or advertisement for employees placed by or on behalf of the Contractor, state that all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, national origin, political affiliation or belief, age, or handicap. (3) The Contractor shall send a copy of the EEO provisions to each labor union or representative of workers with which it has a collective bargaining agreement or other contract or understanding. (4) In the event of the Contractor's noncompliance with these EEO provisions, the City may cancel, terminate, or suspend this contract, in whole or in part, and the City may declare the Contractor ineligible for further City contracts. (5) Unless exempted by the City Council of the City of Durham, the Contractor shall include these EEO provisions in every purchase order for goods to be used in performing this contract and in every subcontract related to this contract so that these EEO provisions will be binding upon such subcontractors and vendors.

  • Audit Requirements for Recipients of State Financial Assistance For purposes of this paragraph, the word "Contractor" shall be deemed to mean "nonstate entity," as that term is defined in section 4-230 of the Connecticut General Statutes. The Contractor shall provide for an annual financial audit acceptable to the Client Agency for any expenditure of State awarded funds made by the Contractor. Such audit shall include management letters and audit recommendations. The State Auditors of Public Accounts shall have access to all records and accounts for the fiscal year(s) in which the award was made. The Contractor shall comply with federal and State single audit standards as applicable.

  • Compliance with the Communications Assistance Law Enforcement Act of 1994

  • Governing Provisions This Agreement is made under and subject to the provisions of the Plan, and all of the provisions of the Plan are also provisions of this Agreement. If there is a difference or conflict between the provisions of this Agreement and the provisions of the Plan, the provisions of the Plan will govern. By signing this Agreement, the Grantee confirms that he or she has received a copy of the Plan.

  • Provisions for Covered Entity to Inform Business Associate of Privacy Practices and Restrictions (a) Covered Entity shall notify Business Associate of any limitation(s) in the notice of privacy practices of Covered Entity under 45 CFR 164.520, to the extent that such limitation may affect Business Associate’s use or disclosure of protected health information.

  • RETENTION AND ACCESS REQUIREMENTS FOR RECORDS ADOF shall retain all records pertinent to this agreement for a period of no less than 3 years from the expiration or termination date. As used in this provision, records includes books, documents, accounting procedures and practice, and other data, regardless of the type or format. ADOF shall provide access and the right to examine all records related to this agreement to the U.S. Forest Service Inspector General, or Comptroller General or their authorized representative. The rights of access in this section must not be limited to the required retention period but must last as long as the records are kept. If any litigation, claim, negotiation, audit, or other action involving the records has been started before the end of the 3-year period, the records must be kept until all issues are resolved, or until the end of the regular 3-year period, whichever is later. Records for nonexpendable property acquired in whole or in part, with Federal funds must be retained for 3 years after its final disposition.

Time is Money Join Law Insider Premium to draft better contracts faster.