Sampling Systems Sample Clauses

Sampling Systems. The gross heating value and composition of the refinery fuel gas will be determined by an on-line gas chromatograph. All samples shall be analyzed using current Gas Processors Association (GPA 2261) standard, "Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography" or Gas Processors Association (GPA 2286) standard, "Tentative Method of Extended Analysis for Natural Gas and Similar Gaseous Mixtures by Temperature Programmed Gas Chromatography". American Petroleum Institute (API MPMS Ch 14.5) or Gas Processors Association (GPA 2172) standards, "Calculation of Gross Heating Value, Relative Density and Compressibility Factor for Natural Gas Mixtures from Compositional Analysis" shall be used to calculate the gross heating value of the samples. These analytical results shall be applied to the volumes measured during the collection period.
AutoNDA by SimpleDocs
Sampling Systems. The hydrogen purity shall be determined by on-line chromatograph or other mutually agreeable method. All samples shall be analyzed using current Gas Processors Association (GPA 2261) standard. "Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography" or Gas Processors Association (GPA 2286) standard, "Tentative Method of Extended Analysis for Natural Gas and Similar Gaseous Mixtures by Temperature Programmed Gas Chromatography". These analytical results shall be applied to the volumes measured during the collection period.

Related to Sampling Systems

  • Sampling Producer shall take one representative origin sample (pint size) from each lot of the corn oil before it leaves the Ethanol Facility (each, a “Sample”). RPMG shall be entitled to witness the taking of Sample. Producer shall label Sample to indicate the applicable corn oil lot numbers, date of shipment, and the truck or railcar number. Producer shall send half of Sample to RPMG promptly upon RPMG’s request. Producer may request that RPMG test results be provided to it at any time after the tests are completed. Producer shall retain corn oil Sample for no less than three (3) months or any longer period required by law. If RPMG knows or reasonably suspects that any corn oil produced by Producer at the Ethanol Facility is not in compliance with the terms of this Agreement, then RPMG may obtain independent laboratory tests of such corn oil, and, if such corn oil is found not to be in compliance with the terms of this Agreement, Producer shall, in addition to its other obligations hereunder, pay all such testing costs.

  • Building Systems The term “Building Systems” means all systems serving the Building in general, including, but not limited to, the fire/life safety, electrical, plumbing, HVAC, including all components thereof and related equipment, but excluding any equipment that is separately installed by or on behalf of Tenant and any distribution systems or equipment existing within the Premises.

  • Review Systems The Asset Representations Reviewer will maintain and utilize an electronic case management system to manage the Tests and provide systematic control over each step in the Review process and ensure consistency and repeatability among the Tests.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Hardware and Software Requirements In order to access and retain Disclosures electronically, you must satisfy the following computer hardware and software requirements: access to the Internet; an email account and related software capable of receiving email through the Internet; a web browser which is SSL-compliant and supports secure sessions, and hardware capable of running this software.

  • Testing Landlord shall have the right to conduct annual tests of the Premises to determine whether any contamination of the Premises or the Project has occurred as a result of Tenant’s use. Tenant shall be required to pay the cost of such annual test of the Premises; provided, however, that if Tenant conducts its own tests of the Premises using third party contractors and test procedures acceptable to Landlord which tests are certified to Landlord, Landlord shall accept such tests in lieu of the annual tests to be paid for by Tenant. In addition, at any time, and from time to time, prior to the expiration or earlier termination of the Term, Landlord shall have the right to conduct appropriate tests of the Premises and the Project to determine if contamination has occurred as a result of Tenant’s use of the Premises. In connection with such testing, upon the request of Landlord, Tenant shall deliver to Landlord or its consultant such non-proprietary information concerning the use of Hazardous Materials in or about the Premises by Tenant or any Tenant Party. If contamination has occurred for which Tenant is liable under this Section 30, Tenant shall pay all costs to conduct such tests. If no such contamination is found, Landlord shall pay the costs of such tests (which shall not constitute an Operating Expense). Landlord shall provide Tenant with a copy of all third party, non-confidential reports and tests of the Premises made by or on behalf of Landlord during the Term without representation or warranty and subject to a confidentiality agreement. Tenant shall, at its sole cost and expense, promptly and satisfactorily remediate any environmental conditions identified by such testing in accordance with all Environmental Requirements. Landlord’s receipt of or satisfaction with any environmental assessment in no way waives any rights which Landlord may have against Tenant.

  • Metering 1. If the Producer desires to sell electric power to the Company, the Company shall provide, own and maintain at the Producer's expense all necessary meters and associated equipment to be utilized for the measurement of energy and capacity for determining the Company's payment to the Producer pursuant to an applicable agreement.

  • Engineering Services The Borrower’s Engineer will provide engineering services covering planning and design, operation of the System, and the supervision and inspection of the construction of the Project. The Borrower’s Engineer will provide to the Department the certificate required by Section 3.4.

  • Technical Specifications Each Bloom System is an integrated system comprised of a fuel cell stack assembly and associated balance of plant components that converts a fuel into electricity using electrochemical means that (i) has a Nameplate Capacity of at least 0.5 kilowatts of electricity using an electrochemical process and (ii) has an electricity-only generation efficiency greater than thirty percent (30%).

Time is Money Join Law Insider Premium to draft better contracts faster.