Common use of Shell Improvements Clause in Contracts

Shell Improvements. The term “Shell Improvements” shall mean the following which have been constructed by Landlord: (i) the shell of a two story industrial building containing approximately 109,786± square feet (not including (a) any atriums, covered entrances or egresses and covered Building loading areas which would bring the total Building size to 111,465 ± square feet, and (b) any potential bridge between this Building 5 and adjacent Building 6 (the “Building Connector”)), consisting of foundation, first and second story floor slab, building exterior precast concrete panels, building exterior window wall system (including standard ten foot high exterior doors and standard exterior door hardware), load bearing walls, roof system for standard loading, roof membrane, roof screen; (ii) sitework improvements consisting of offsite sanitary sewer piping from street main to property line, offsite domestic water and fire service from street mains to property line, full “shell” fire-sprinkler systems; functional interior stairs per plan (concrete-filled metal stair tread pans in unfinished gypsum-board enclosures with no hand rails or finishes); 2-elevator core with one elevator installed and functional (State inspected and signed off); (iii) primary electrical power to pad-mounted transformers adjacent to Building, electrical power to panels within electrical room of Building sufficient to support elevator, emergency interior lighting, utility power and lighting in electrical and elevator equipment rooms; exterior parking lot standards & lighting; interior roof insulation; Building security system; telephone utility conduits from telephone utility vault at the street to electrical room in the Building; gas line stubbed from street to proposed gas meter pad location outside Building proximate to transformer; domestic water stubbed into interior of building; sanitary sewer gut line installed under slab from end stair well to end stair well connected to the exterior service of the Building; storm offsite and onsite storm sewer (for exterior water drainage system), paving and parking areas, striping, sidewalks, parking curbs, gutters, irrigation system and landscaping. The plans for the Shell Improvements are known hereafter as the “Shell Plans”. Notwithstanding anything to the contrary herein, (i) all Shell Improvements provided by Landlord are Landlord’s standard items, and (ii) Landlord shall not be responsible or liable to construct any other improvements, of any type whatsoever, to the shell or to the exterior or interior of said Building and/or Premises.

Appears in 2 contracts

Samples: Lease Agreement (Genitope Corp), Genitope Corp

AutoNDA by SimpleDocs

Shell Improvements. The term “Shell Improvements” shall mean the following which have been constructed by Landlord: (i) the shell of a two story industrial building containing approximately 109,786± square feet (not including (a) any atriums, covered entrances or egresses and covered Building loading areas which would bring the total Building size to 111,465 ± square feet, and (b) any potential bridge between this Building 5 6 and adjacent Building 6 5 (the “Building Connector”)), consisting of foundation, first and second story floor slab, building exterior precast concrete panels, building exterior window wall system (including standard ten foot high exterior doors and standard exterior door hardware), load bearing walls, roof system for standard loading, roof membrane, roof screen; (ii) sitework improvements consisting of offsite sanitary sewer piping from street main to property line, offsite domestic water and fire service from street mains to property line, full “shell” fire-sprinkler systems; functional interior stairs per plan (concrete-filled metal stair tread pans in unfinished gypsum-board enclosures with no hand rails or finishes); 2-elevator core with one elevator installed and functional (State inspected and signed off); (iii) primary electrical power to pad-mounted transformers adjacent to Building, electrical power to panels within electrical room of Building sufficient to support elevator, emergency interior lighting, utility power and lighting in electrical and elevator equipment rooms; exterior parking lot standards & lighting; interior roof insulation; Building security system; telephone utility conduits from telephone utility vault at the street to electrical room in the Building; gas line stubbed from street to proposed gas meter pad location outside Building proximate to transformer; domestic water stubbed into interior of building; sanitary sewer gut line installed under slab from end stair well to end stair well connected to the exterior service of the Building; storm offsite and onsite storm sewer (for exterior water drainage system), paving and parking areas, striping, sidewalks, parking curbs, gutters, irrigation system and landscaping. The plans for the Shell Improvements are known hereafter as the “Shell Plans”. Notwithstanding anything to the contrary herein, (i) all Shell Improvements provided by Landlord are Landlord’s standard items, and (ii) Landlord shall not be responsible or liable to construct any other improvements, of any type whatsoever, to the shell or to the exterior or interior of said Building and/or Premises.

Appears in 2 contracts

Samples: Lease Agreement (Genitope Corp), Genitope Corp

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!