Sub stations Sample Clauses

Sub stations. The Contractor executes maintenance as per the Eskom maintenance strategies in all overland conveyor belts substation 1,2 and 3 including OTS and Driefontein Dam substations: SYSTEM COMPONENT ACTION 24V Brds and Chargers Remove panel covers and clean boards and chargers Check all busbars, cabling and switchgear panels Check all fuse holders, clip-on terminals and connections Check that all the SCR's are operating correctly (phase balancing) Check and correct voltage& current settings Verify that alarms are received and aknowledged by an operator Measure the standing load current Measure the ripple voltage from the charger/UPS to the battery bank Perform DC integrity test when unit is within the operators control& the plant should not trip Clean board internally Check and correct alarm settings Carry out 24V DC dual supply checks (50 Amp and 16 Amp supplies) Check for voltage differences between "O" potential and MZ (non-current caring supply) Measure and normalise the ac incoming supply voltage Replace indicating lamps Record the charger voltage and current Ensure the battery charger is in float mode when taking readings Ensure the battery voltage does not drop by 10% Calibrate chargers Check, record and report all alarms to the responsible person Perform full functional test Inverter Clean inverter panel Check all connections, fuse holders and terminals Calibrate inverter charger Clean filters Check if alarm wiring is correct Check all alarms Perform full functional test Tighten and torgue the battery cell connections Batteries Check for cracks and leaks on the cells Measure voltage on each cell and record it Check connecters for corrosion Check Flaking of cells Inspect the water level and top up if necessary Check for hot spots on termination points Check battery stands for corrosion Based on routine maintenance reading perform equalise charge on every battery bank with cells out of step. Measure and record voltage on the all battery cells Perform discharge test on the 24V & 220V battery banks and record the results Electrolyte Top up the cell if below minimum xxxx Use demineralised was to top up Log the volume of water consumed and cell number Measure pilot cell Vlotage Measure pilot cell temperature (25 degrees C) Take specific gravity measurements (SG) on the all the cells Battery Cabinet Inspect and replace the safety equipments if need be Inspect ventilation whether is working Inspect lighting Inspect and clean the room The Contractor inspects and e...
AutoNDA by SimpleDocs

Related to Sub stations

  • Pipelines Developer shall have no interest in the pipeline gathering system, which gathering system shall remain the sole property of Operator or its Affiliates and shall be maintained at their sole cost and expense.

  • Terminals Hartford Terminal. Hartford Terminal is located at or near Hartford, Illinois. The facility consists of a two-bay truck rack with 17,000 barrels of active terminaling capacity, 13 above-ground storage tanks with approximately 1.1 million barrels of total storage capacity. The Hartford barge dock consists of a single-berth barge loading facility, approximately 0.8 miles of 8-inch pipeline and approximately 0.8 miles of 14-inch pipeline from the Hartford terminal to the Hartford barge dock for delivery.

  • Interconnection Facilities 4.1.1 The Interconnection Customer shall pay for the cost of the Interconnection Facilities itemized in Attachment 2 of this Agreement. The NYISO, in consultation with the Connecting Transmission Owner, shall provide a best estimate cost, including overheads, for the purchase and construction of its Interconnection Facilities and provide a detailed itemization of such costs. Costs associated with Interconnection Facilities may be shared with other entities that may benefit from such facilities by agreement of the Interconnection Customer, such other entities, the NYISO, and the Connecting Transmission Owner.

  • Information regarding Interconnection Facilities 4.2.1 The SPD shall be required to obtain all information from the STU/CTU/concerned authority with regard to the Interconnection Facilities as is reasonably necessary to enable it to design, install and operate all interconnection plant and apparatus on the SPD’s side of the Delivery Point to enable delivery of electricity at the Delivery Point. The transmission of power up to the point of interconnection where the metering is done for energy accounting shall be the responsibility of the SPD at his own cost.

  • Interconnection Customer’s Interconnection Facilities Construction The Interconnection Customer’s Interconnection Facilities shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Participating TO and Interconnection Customer agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Participating TO and CAISO “as-built” drawings, information and documents for the Interconnection Customer’s Interconnection Facilities and the Electric Generating Unit(s), such as: a one-line diagram, a site plan showing the Large Generating Facility and the Interconnection Customer’s Interconnection Facilities, plan and elevation drawings showing the layout of the Interconnection Customer’s Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Large Generating Facility to the step-up transformers and the Interconnection Customer’s Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Electric Generating Units. The Interconnection Customer shall provide the Participating TO and the CAISO specifications for the excitation system, automatic voltage regulator, Large Generating Facility control and protection settings, transformer tap settings, and communications, if applicable. Any deviations from the relay settings, machine specifications, and other specifications originally submitted by the Interconnection Customer shall be assessed by the Participating TO and the CAISO pursuant to the appropriate provisions of this LGIA and the LGIP.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Two-Way Interconnection Trunks 2.4.1 Where the Parties have agreed to use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and VarTec, VarTec shall order from Verizon, and Verizon shall provide, the Two-Way Interconnection Trunks and the Entrance Facility, on which such Trunks will ride, and transport and multiplexing, in accordance with the rates, terms and conditions set forth in this Agreement and Verizon’s applicable Tariffs.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Interconnection 2.1.10 Startup Testing and Commissioning

  • Interconnection Customer’s Interconnection Facilities The Interconnection Customer shall design, procure, construct, install, own and/or control the Interconnection Customer’s Interconnection Facilities described in Appendix A at its sole expense.