Common use of Test phase Clause in Contracts

Test phase. The vehicle shall be positioned on the ground plane. The electrical surge shall be applied on the vehicle on the AC/DC power lines between each line and earth and between lines by using CDN as described in Figures 1a to 1d of Appendix 1 to this annex, The test setup shall be noted in the test report. Figure 1 Vehicle in configuration "REESS charging mode coupled to the power grid" Example of test setup for vehicle with plug located on vehicle side Figure 1a Figure 1b Legend:

Appears in 5 contracts

Samples: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles

AutoNDA by SimpleDocs

Test phase. The vehicle shall be positioned on the ground plane. The electrical surge fast transient/burst (EFT/B) shall be applied on the vehicle on the AC/DC power lines between each line and earth and between lines in common modes by using CDN as described in Figures Figure 1a to 1d of Appendix 1 to this annex, . The test setup set-up shall be noted in the test report. Figure 1 Vehicle in configuration "REESS charging mode coupled to the power grid" Example of test setup for vehicle with plug located on vehicle side Figure 1a Figure 1b Legend:

Appears in 4 contracts

Samples: Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles

AutoNDA by SimpleDocs

Test phase. The vehicle shall be positioned on the ground plane. The electrical surge fast transient/burst (EFT/B) shall be applied on the vehicle on the AC/DC power lines between each line and earth and between lines in common modes by using CDN as described in Figures 1a to 1d appendix 1, figure 1 of Appendix 1 to this annex, The test setup shall must be noted in the test report. Figure 1 Vehicle in configuration "REESS charging mode coupled to the power grid" Example of test setup for vehicle with plug located on vehicle side Figure 1a Figure 1b Legend:1

Appears in 2 contracts

Samples: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles