TOWER SUBSYSTEM Sample Clauses

TOWER SUBSYSTEM. Tower System contractor shall perform the following site construction pertaining to the generator equipment per the RFP. ATTACHED GENERATOR ROOM CONFIGURATION >> Provide extension ground cable(s) from exterior halo ground system to be bonded to fuel tank(s) -------------------------------------------------------------------------------- 2144 PA Rider B Page 30 of 46 March 22, 2000 Rider B - Statement of Work -------------------------------------------------------------------------------- >> Construct foundation(s) for fuel tank(s) DETACHED GENERATOR ROOM CONFIGURATION >> Provide extension ground cable(s) from exterior halo ground system to be bonded to fuel tank(s) >> Provide three (3) extension ground cables from exterior halo ground system to be routed into the detached generator room for bonding to generator engine block, alternator, and electrical distribution panel >> Install generator AC power, alarm/control, and utility AC power conduits from shelter to detached generator room >> Construct foundation(s) for fuel tank(s) and detached generator room OUTSIDE GENERATOR CONFIGURATION >> Provide extension ground cable(s) from exterior halo ground system to be bonded to fuel tank(s) >> Provide three (3) extension ground cables from exterior halo ground system to be routed into the detached generator room for bonding to generator engine block, alternator, and electrical distribution panel >> Install generator AC power, alarm/control, and utility AC power conduits from shelter to detached generator room >> Construct foundation(s) for fuel tank(s) and detached generator room
AutoNDA by SimpleDocs

Related to TOWER SUBSYSTEM

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Communications Equipment Members of the board of directors or any committee thereof may participate in and act at any meeting of such board or committee through the use of a conference telephone or other communications equipment by means of which all persons participating in the meeting can hear each other, and participation in the meeting pursuant to this section shall constitute presence in person at the meeting.

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • Hardware and Software Requirements In order to access and retain Disclosures electronically, you must satisfy the following computer hardware and software requirements: access to the Internet; an email account and related software capable of receiving email through the Internet; a web browser which is SSL-compliant and supports secure sessions, and hardware capable of running this software.

  • HORIZONR Gateway HORIZONR Gateway provides customers with the ability to (i) generate reports using information maintained on the Multicurrency HORIZONR Accounting System which may be viewed or printed at the customer’s location; (ii) extract and download data from the Multicurrency HORIZONR Accounting System; and (iii) access previous day and historical data. The following information which may be accessed for these purposes: 1) holdings; 2) holdings pricing; 3) transactions, 4) open trades; 5) income; 6) general ledger and 7) cash.

  • Interconnection If Manager desires to interconnect a portion of the Service Area Network with another carrier and Sprint PCS can interconnect with that carrier at a lower rate, then to the extent permitted by applicable laws, tariffs and contracts, Sprint PCS may arrange for the interconnection under its agreements with the carrier and if it does so, Sprint PCS will xxxx the interconnection fees to Manager.

  • Site Visits DOE’s authorized representatives have the right to make site visits at reasonable times to review project accomplishments and management control systems and to provide technical assistance, if required. You must provide, and must require your subawardees to provide, reasonable access to facilities, office space, resources, and assistance for the safety and convenience of the government representatives in the performance of their duties. All site visits and evaluations must be performed in a manner that does not unduly interfere with or delay the work.

  • Compatibility The Spacecraft Bus shall be compatible with standard GPS interfaces as defined in [**Redacted**].

  • Sprinkler System If there now is or shall be installed in the Building a "sprinkler system", and such system or any of its appliances shall be damaged or injured or not in proper working order by reason of any act or omission of Tenant, Tenant's agents, servants, employees, licensees or visitors, Tenant shall forthwith restore the same to good working condition at its own expense; and if the New York Board of Fire Underwriters or the New York Fire Insurance Rating Organization or any bureau, department or official of the state or city government, shall require or recommend that any changes, modifications, alterations or additional sprinkler heads or other equipment be made or supplied by reason of Tenant's business, or the location of the partitions, trade fixtures, or other contents of the Premises, Tenant shall, at Tenant's expense, promptly make and supply such changes, modifications, alterations, additional sprinkler heads or other equipment.

  • External Hosting Facilities Transfer Agent shall implement controls, consistent with applicable prevailing industry practices and standards, regarding the collection, use, storage and/or disclosure of Fund Data by an external hosting provider.

Time is Money Join Law Insider Premium to draft better contracts faster.