Tree Canopy Outcome Sample Clauses

Tree Canopy Outcome. Continually increase urban tree canopy capacity to provide air quality, water quality and habitat benefits throughout the watershed. Expand urban tree canopy by 2,400 acres by 2025. Learn more about this outcome. Water Quality: Reduce pollutants to achieve the water quality necessary to support the aquatic living resources of the Bay and its tributaries and protect human health. 2017 Watershed Implementation Plans (WIP) Outcome: By 2017, have practices and controls in place that are expected to achieve 60 percent of the nutrient and sediment pollution load reductions necessary to achieve applicable water quality standards compared to 2009 levels. Learn more about this outcome. 2025 Watershed Implementation Plans (WIP) Outcome: By 2025, have all practices and controls installed to achieve the Bay’s dissolved oxygen, water clarity/submerged aquatic vegetation and chlorophyll a standards as articulated in the Chesapeake Bay TMDL document. Learn more about this outcome. Water Quality Standards Attainment and Monitoring Outcome: Continually improve the capacity to monitor and assess the effects of management actions being undertaken to implement the Bay TMDL and improve water quality. Use the monitoring results to report annually to the public on progress made in attaining established Bay water-quality standards and trends in reducing nutrients and sediment in the watershed. Learn more about this outcome.
AutoNDA by SimpleDocs
Tree Canopy Outcome. Continually increase urban tree canopy capacity to provide for air quality, water quality, and habitat benefits throughout the watershed. Expand urban tree canopy by 2,400 acres by 2025.

Related to Tree Canopy Outcome

  • Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.

  • RE-WEIGHING PRODUCT Deliveries are subject to re- weighing at the point of destination by the Authorized User. If shrinkage occurs which exceeds that normally allowable in the trade, the Authorized User shall have the option to require delivery of the difference in quantity or to reduce the payment accordingly. Such option shall be exercised in writing by the Authorized User.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.

  • Mail Order Catalog Warnings In the event that, the Settling Entity prints new catalogs and sells units of the Products via mail order through such catalogs to California consumers or through its customers, the Settling Entity shall provide a warning for each unit of such Product both on the label in accordance with subsection 2.4 above, and in the catalog in a manner that clearly associates the warning with the specific Product being purchased. Any warning provided in a mail order catalog shall be in the same type size or larger than other consumer information conveyed for such Product within the catalog and shall be located on the same display page of the item. The catalog warning may use the Short-Form Warning content described in subsection 2.3(b) if the language provided on the Product label also uses the Short-Form Warning.

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • CFR PART 200 Procurement of Recovered Materials A non-Federal entity that is a state agency or agency of a political subdivision of a state and its contractors must comply with section 6002 of the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act. The requirements of Section 6002 include procuring only items designated in guidelines of the Environmental Protection Agency (EPA) at 40 CFR part 247 that contain the highest percentage of recovered materials practicable, consistent with maintaining a satisfactory level of competition, where the purchase price of the item exceeds $10,000 or the value of the quantity acquired during the preceding fiscal year exceeded $10,000; procuring solid waste management services in a manner that maximizes energy and resource recovery; and establishing an affirmative procurement program for procurement of recovered materials identified in the EPA guidelines. Does vendor certify that it is in compliance with the Solid Waste Disposal Act as described above? Yes

  • COVID-19 Vaccine Passports Pursuant to Texas Health and Safety Code, Section 161.0085(c), Contractor certifies that it does not require its customers to provide any documentation certifying the customer’s COVID-19 vaccination or post-transmission recovery on entry to, to gain access to, or to receive service from the Contractor’s business. Contractor acknowledges that such a vaccine or recovery requirement would make Contractor ineligible for a state-funded contract.

  • DRUG/ALCOHOL TESTING Section 33.1 Drug testing may be conducted on employees during their duty hours upon reasonable suspicion or randomly by computer selection. Alcohol testing will be conducted only upon reasonable suspicion. Reasonable suspicion that an employee used or is using a controlled substance or alcohol in an unlawful or abusive manner may be based upon, but not limited to: A. Observable phenomena, such as direct observation of drug or alcohol use or possession and/or the physical symptoms of being under the influence of a drug or alcohol; B. A pattern or abnormal conduct or erratic behavior, including abnormal leave patterns; C. Arrest or conviction for a drug or alcohol-related offense, or the identification of an employee as the focus of a criminal investigation into illegal drug or alcohol possession, use, or trafficking; D. Information provided either by reliable and credible sources or independently corroborated; E. Evidence that an employee has tampered with a previous drug test; F. Facts or circumstances developed in the course of an authorized investigation of an accident or unsafe working practices. Section 33.2 Drug/alcohol testing shall be conducted solely for administrative purposes and the results obtained shall not be used in criminal proceedings. Under no circumstances may the results of drug/alcohol screening or testing be released to a third party for use in a criminal prosecution against the affected employee. The following procedure shall not preclude the Employer from other administrative action but such actions shall not be based solely upon the initial reagent testing results alone. Section 33.3 All drug screening tests shall be conducted by laboratories meeting the standards of the Substance Abuse and Mental Health Service Administration. No test shall be considered positive until it has been confirmed by a Gas Chromatography/Mass Spectrometry. The procedures utilized by the Employer and testing laboratory shall include an evidentiary chain of custody control and split sample testing. All procedures shall be outlined in writing and this outline shall be followed in all situations arising under this article. Section 33.4 Alcohol testing shall be done in accordance with the law of the State of Ohio to detect drivers operating a motor vehicle under the influence. A positive result shall entitle the Employer to proceed with sanctions as set forth in this Article. Section 33.5 The results of the testing shall be delivered to a specified employee of the Employer with command responsibility and the employee tested. An employee whose confirmatory test result is positive shall have the right to request a certified copy of the testing results in which the vendor shall affirm that the test results were obtained using the approved protocol methods. The employee shall provide a signed release for disclosure of the testing results to the Employer. A representative for the bargaining unit shall have a right of access to the results upon request to the Employer, with the employee’s written consent. Refusal to submit to the testing provided for under this Agreement may be grounds for discipline. A. If a drug screening test is positive, a confirmatory test shall be conducted utilizing the fluid from the primary sample. B. In the event that any confirmation drug test results are positive, the employee is entitled to have the split sample tested by another DHHS-certified lab in the manner prescribed above at the employee’s expense. The employee must request the split sample test within seventy-two (72) hours of being notified of a positive result. The results of this test, whether positive or negative, shall be determinative. Section 33.7 A list of three (3) testing laboratories shall be maintained by the Employer. These laboratories shall conduct any testing directed by the Employer. The Employer shall obtain the approval of the bargaining unit representative as to any laboratories put on this list, which approval shall not be unreasonably withheld. Section 33.8 If after the testing required above has produced a positive result the Employer may require the employee to participate in any rehabilitation or detoxification program that is covered by the employee’s health insurance. Discipline allowed by the positive findings provided for above shall be deferred pending rehabilitation of the employee within a reasonable period. An employee who participates in a rehabilitation or detoxification program shall be allowed to use sick time and vacation leave for the period of the rehabilitation or detoxification program. If no such leave credits are available, the employee shall be placed on medical leave of absence without pay for the period of the rehabilitation or detoxification program. Upon completion of such program and upon receiving results from a retest demonstrating that the employee is no longer abusing a controlled substance/alcohol, the employee shall be returned to his/her former position. Such employee may be subject to periodic retesting upon his/her return to his/her position for a period of one (1) year from the date of his/her return to work. Any employee in a rehabilitation or detoxification program in accordance with this Article will not lose any seniority or benefits, should it be necessary for the employee to be placed on medical leave of absence without pay, for a period not to exceed ninety (90) days. Section 33.9 If the employee refuses to undergo rehabilitation or detoxification, or if he/she tests positive during a retesting within one (1) year after his/her return to work from such a program, the employee shall be subject to disciplinary action, including removal from his/her position and termination of his/her employment. Section 33.10 Costs of all drug screening tests and confirmatory tests shall be borne by the Employer except that any test initiated at the request of the employee shall be at the employee’s expense. Section 33.11 The Employer may conduct four (4) tests of an employee during the one (1) year period after the employee has completed a rehabilitation or detoxification program as provided above. Section 33.12 The provisions of this Article shall not require the Employer to offer a rehabilitation/detoxification program to any employee more than once.

  • Commercial Price List Reductions Where NYS Net Prices are based on a discount from Contractor’s list prices, price decreases shall take effect automatically during the Contract term and apply to Purchase Orders submitted on or after the date Contractor lowers its pricing to its customers generally or to similarly situated government customers during the Contract term; or

  • Equipment Procurement If responsibility for construction of the Connecting Transmission Owner’s Attachment Facilities or System Upgrade Facilities or System Deliverability Upgrades is to be borne by the Connecting Transmission Owner, then the Connecting Transmission Owner shall commence design of the Connecting Transmission Owner’s Attachment Facilities or System Upgrade Facilities or System Deliverability Upgrades and procure necessary equipment as soon as practicable after all of the following conditions are satisfied, unless the Developer and Connecting Transmission Owner otherwise agree in writing: 5.5.1 NYISO and Connecting Transmission Owner have completed the Interconnection Facilities Study pursuant to the Interconnection Facilities Study Agreement; 5.5.2 The NYISO has completed the required cost allocation analyses, and Developer has accepted his share of the costs for necessary System Upgrade Facilities and System Deliverability Upgrades in accordance with the provisions of Attachment S of the NYISO OATT; 5.5.3 The Connecting Transmission Owner has received written authorization to proceed with design and procurement from the Developer by the date specified in Appendix B hereto; and 5.5.4 The Developer has provided security to the Connecting Transmission Owner in accordance with Article 11.5 by the dates specified in Appendix B hereto.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!