Examples of Covered Refineries in a sentence
By no later than December 31, 2017, MPC will maintain one 95 kscfh liquid ring Compressor and one 120 kscfh liquid ring Compressor at a location where these Compressors can be delivered to the Five Covered Refineries within 24 hours of notification of need.
For the Five Covered Refineries, in each semi-annual report due after the dates in Column J of Appendix 2.1, MPC shall provide sufficient information to document compliance with the FGRS operational requirements set forth in Paragraph 38D.
The provisions of the Consent Decree shall apply to the Covered Refineries.
As specified by this Subsection V.K, and consistent with the requirements of 40 C.F.R. § 60.11(d), ExxonMobil shall investigate the cause of future AG Flaring Incidents and Tail Gas Incidents, take reasonable steps to correct the conditions that have caused or contributed to such AG Flaring Incidents and Tail Gas Incidents, and minimize AG Flaring Incidents and Tail Gas Incidents at the Covered Refineries.
ExxonMobil has conducted a review of past AG Flaring Incidents that occurred at the Covered Refineries between January 1, 1998 and December 1, 2004, and has provided EPA a summary identifying the AG Flaring Incidents that occurred during that period, their probable causes, and the estimated emissions.
ExxonMobil shall comply with the requirements of this Paragraph 102 at all locations at the Covered Refineries where a carbon canister(s) is utilized as a control device under the Benzene Waste NESHAP.
Effective on the Entry Date, ExxonMobil shall not burn Fuel Oil in any combustion unit at any of the Covered Refineries except during periods of Natural Gas Curtailment.
ExxonMobil owns and/or operates the FCCUs identified below at the Covered Refineries.
For the Five Covered Refineries, in each semi-annual report due after the dates in Column J of Appendix 2.1, MPC shall provide sufficient information to document compliance with the FGRS operational requirements set forth in Paragraph 38D.
In determining flow rate, flows during all periods (including but not limited to normal operations and periods of Startup, Shutdown, Malfunction, process upsets, relief valve leakages, power losses due to an interruptible power service agreement, and emergencies arising from events within the boundaries of each of the Covered Refineries), except those described in the next sentence, shall be included.