We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.
For more information visit our privacy policy.Conditions When the Government May Obtain Title Upon DARPA’s written request, the Performer shall convey title to any Subject Invention to DARPA under any of the following conditions: 1. If the Performer fails to disclose or elects not to retain title to the Subject Invention within the times specified in Paragraph B of this Article; however, DARPA may only request title within sixty (60) calendar days after learning of the failure of the Performer to disclose or elect within the specified times; 2. In those countries in which the Performer fails to file patent applications within the times specified in Paragraph B of this Article; however, if the Performer has filed a patent application in a country after the times specified in Paragraph B of this Article, but prior to its receipt of the written request by DARPA, the Performer shall continue to retain title in that country; or 3. In any country in which the Performer decides not to continue the prosecution of any application for, to pay the maintenance fees on, or defend in reexamination or opposition proceedings on, a patent on a Subject Invention.
PROHIBITION ON CERTAIN TELECOMMUNICATIONS AND VIDEO SURVEILLANCE SERVICES OR EQUIPMENT To the extent applicable, Supplier certifies that during the term of this Contract it will comply with applicable requirements of 2 C.F.R. § 200.216.
Internet Use Customer assumes total responsibility for its and its users’ use of the Internet. Masergy specifically disclaims any warranties, endorsements or representations regarding any merchandise, information, software, products, data, files, or services provided through the Internet.
Access to NID 2.7.3.1 NewPhone may access the customer’s premises wiring by any of the following means and NewPhone shall not disturb the existing form of electrical protection and shall maintain the physical integrity of the NID: 2.7.3.1.1 BellSouth shall allow NewPhone to connect its Loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premises; 2.7.3.1.2 Where an adequate length of the customer’s premises wiring is present and environmental conditions permit, either Party may remove the customer premises wiring from the other Party’s NID and connect such wiring to that Party’s own NID; 2.7.3.1.3 Either Party may enter the subscriber access chamber or dual chamber NID enclosures for the purpose of extending a cross-connect or spliced jumper wire from the customer premises wiring through a suitable “punch-out” hole of such NID enclosures; or 2.7.3.1.4 NewPhone may request BellSouth to make other rearrangements to the customer premises wiring terminations or terminal enclosure on a time and materials cost basis. 2.7.3.2 In no case shall either Party remove or disconnect the other Party’s loop facilities from either Party’s NIDs, enclosures, or protectors unless the applicable Commission has expressly permitted the same and the disconnecting Party provides prior notice to the other Party. In such cases, it shall be the responsibility of the Party disconnecting loop facilities to leave undisturbed the existing form of electrical protection and to maintain the physical integrity of the NID. It will be NewPhone’s responsibility to ensure there is no safety hazard, and NewPhone will hold BellSouth harmless for any liability associated with the removal of the BellSouth Loop from the BellSouth NID. Furthermore, it shall be the responsibility of the disconnecting Party, once the other Party’s loop has been disconnected from the NID, to reconnect the disconnected loop to a nationally recognized testing laboratory listed station protector, which has been grounded as per Article 800 of the National Electrical Code. If no spare station protector exists in the NID, the disconnected loop must be appropriately cleared, capped and stored. 2.7.3.3 NewPhone shall not remove or disconnect ground wires from BellSouth’s NIDs, enclosures, or protectors. 2.7.3.4 NewPhone shall not remove or disconnect NID modules, protectors, or terminals from BellSouth’s NID enclosures. 2.7.3.5 Due to the wide variety of NID enclosures and outside plant environments, BellSouth will work with NewPhone to develop specific procedures to establish the most effective means of implementing this section if the procedures set forth herein do not apply to the NID in question.
Possession and Use Contractor may possess, use and reproduce Confidential Information solely for the Purpose. Contractor shall not use the Confidential Information for any other purpose.
Scope of Use The Fund will use the System and the Data Access Services only for the processing of securities transactions, the keeping of books of account for the Fund and accessing data for purposes of reporting and analysis. The Fund shall not, and shall cause its employees and agents not to (i) permit any unauthorized third party to use the System or the Data Access Services, (ii) sell, rent, license or otherwise use the System or the Data Access Services in the operation of a service bureau or for any purpose other than as expressly authorized under this Addendum, (iii) use the System or the Data Access Services for any fund, trust or other investment vehicle), other than as set forth herein, without the prior written consent of State Street, (iv) allow access to the System or the Data Access Services through terminals or any other computer or telecommunications facilities located outside the Designated Locations, (v) allow or cause any information (other than portfolio holdings, valuations of portfolio holdings, and other information reasonably necessary for the management or distribution of the assets of the Fund) transmitted from State Street’s databases, including data from third party sources, available through use of the System or the Data Access Services to be redistributed or retransmitted to another computer, terminal or other device for other than use for or on behalf of the Fund or (vi) modify the System in any way, including without limitation developing any software for or attaching any devices or computer programs to any equipment, system, software or database which forms a part of or is resident on the Designated Configuration.
Dewatering (a) Where the whole of a site is so affected by surface water following a period of rain that all productive work is suspended by agreement of the Parties, then dewatering shall proceed as above with Employees so engaged being paid at penalty rates as is the case for safety rectification work. This work is typically performed by Employees engaged within CW1, CW2 or CW3 classifications. When other Employees are undertaking productive work in an area or areas not so affected then dewatering will only attract single time rates. (b) Where a part of a site is affected by surface water following a period of rain, thus rendering some areas unsafe for productive work, consistent with the Employer’s obligations under the OH&S Act, appropriate Employees shall assist in the tidying up of their own work site or area if it is so affected. Where required, appropriate Employees will be provided with the appropriate PPE. Such work to be paid at single time rates. Productive work will continue in areas not so affected. (c) To avoid any confusion any ‘dewatering’ time which prevents an Employee from being engaged in their normal productive work is not included in any calculation for the purposes of determining whether an Employee is entitled to go home due to wet weather (refer clauses 32.4 and 32.5)
Information Technology Accessibility Standards Any information technology related products or services purchased, used or maintained through this Grant must be compatible with the principles and goals contained in the Electronic and Information Technology Accessibility Standards adopted by the Architectural and Transportation Barriers Compliance Board under Section 508 of the federal Rehabilitation Act of 1973 (29 U.S.C. §794d), as amended. The federal Electronic and Information Technology Accessibility Standards can be found at: xxxx://xxx.xxxxxx-xxxxx.xxx/508.htm.
Access to Site 3.05.1 Contractor may enter and leave the premises at all reasonable times without charge. Contractor and its employees may use the common areas and roadways of the premises where it is to perform the services together with all facilities, equipment, improvements, and services provided in connection with the premises for common use. This excludes parking for Contractor’s personnel. Contractor shall repair any damage caused by it or its employees as a result of its use of the common areas.
Accessibility Supplier warrants that all Products will meet the requirements set forth in all federal, state, local and foreign laws, rules, and regulations applicable to accessibility of information technology for people with disabilities. Supplier agrees to use personnel trained and knowledgeable in supporting the needs of persons with disabilities in performance of Services under this Order.