Accelerated life test. Eight TPRD units undergo testing; three at the manufacturer's specified activation temperature, Tact, and five at an accelerated life temperature, Tlife = 9.1 x Tact0.503. The TPRD is placed in an oven or liquid bath with the temperature held constant (±1 °C). The hydrogen gas pressure on the TPRD inlet is 125 per cent NWP (±1 MPa). The pressure supply may be located outside the controlled temperature oven or bath. Each device is pressured individually or through a manifold system. If a manifold system is used, each pressure connection includes a check valve to prevent pressure depletion of the system when one specimen fails. The three TPRDs tested at Tact shall activate in less than ten hours. The five TPRDs tested at Tlife shall not activate in less than 500 hours.
Accelerated life test. Eight TPRD units undergo testing; three at the manufacturer's specified activation temperature, Tf, and five at an accelerated life temperature. The Accelerated Life test temperature is TL, given in °C by the expression: 0.502 𝑇𝐿 = (𝛽 + 𝑇 0.498 −1 + ) Where β = 273.15, TME is 85 °C, and Tf is the manufacturer's specified activation temperature. The TPRD is placed in an oven or liquid bath with the temperature held constant (±1 °C). The pressure on the TPRD inlet is ≥ 125 per cent NWP. The pressure supply may be located outside the controlled temperature oven or bath. Each device is pressurized individually or through a manifold system. If a manifold system is used, each pressure connection may include a check valve to prevent pressure depletion of the system when one specimen fails. The three TPRDs tested at Tf shall activate in less than 10 hours. The five TPRDs tested at TL shall not activate in less than 500 hours and shall meet the requirements of Annex4, paragraph 1.8. (Leak test).
Accelerated life test. Eight TPRD units undergo testing; three at the manufacturer's specified activation temperature, Tf, and five at an accelerated life temperature. The Accelerated Life test temperature is TL, given in °C by the expression: Where β = 273.15, TME is 85 °C, and Tf is the manufacturer's specified activation temperature. The TPRD is placed in an oven or liquid bath with the temperature held constant (±1 °C). The pressure on the TPRD inlet is ≥ 125 per cent NWP. The pressure supply may be located outside the controlled temperature oven or bath. Each device is pressurized individually or through a manifold system. If a manifold system is used, each pressure connection may include a check valve to prevent pressure depletion of the system when one specimen fails. The three TPRDs tested at Tf shall activate in less than 10 hours. The five TPRDs tested at TL shall not activate in less than 500 hours and shall meet the requirements of Annex4, paragraph 1.8. (Leak test).

Related to Accelerated life test

  • Follow-up Testing An employee shall submit to unscheduled follow-up drug and/or alcohol testing if, within the previous 24-month period, the employee voluntarily disclosed drug or alcohol problems, entered into or completed a rehabilitation program for drug or alcohol abuse, failed or refused a preappointment drug test, or was disciplined for violating the provisions of this Agreement and Employer work rules. The Employer may require an employee who is subject to follow-up testing to submit to no more than six unscheduled drug or alcohol tests within any 12 month period.