Acceptance conditions. The access probe shall not touch live parts. If this requirement is verified by a signal circuit between the probe and live parts, the lamp shall not light. In the case of the test for IPXXB, the jointed test finger may penetrate to its 80 mm length, but the stop face (diameter 50 mm x 20 mm) shall not pass through the opening. Starting from the straight position, both joints of the test finger shall be successively bent through an angle of up to 90 degree with respect to the axis of the adjoining section of the finger and shall be placed in every possible position.
Appears in 2 contracts
Samples: Regulation 95 Concerning the Approval of Vehicles Regarding the Protection of Occupants in the Event of a Lateral Collision, Agreement Concerning the Adoption of Uniform Conditions of Approval and Reciprocal Recognition of Approval for Motor Vehicle Equipment and Parts
Acceptance conditions. The access probe shall not touch live parts. If this requirement is verified by a signal circuit between the probe and live parts, the lamp shall not light. In the case of the test for IPXXB, the jointed test finger may penetrate to its 80 mm length, but the stop face (diameter 50 mm x 20 mm) shall not pass through the opening. Starting from the straight position, both joints of the test finger shall be successively bent through an angle of up to 90 tob90 degree with respect to the axis of the adjoining section of the finger and shall be placed in every possible position.. In case of the tests for IPXXD, the access probe may penetrate to its full length, but the stop face shall not fully penetrate through the opening
Appears in 1 contract
Samples: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles
Acceptance conditions. The access probe shall not touch live parts. If this requirement is verified by a signal circuit between the probe and live parts, the lamp shall not light. In the case of the test for IPXXB, the jointed test finger may penetrate to its 80 mm length, but the stop face (diameter 50 mm x 20 mm) shall not pass through the opening. Starting from the straight position, both joints of the test finger shall be successively bent through an angle of up to 90 degree degrees with respect to the axis of the adjoining section of the finger and shall be placed in every possible position.. In case of the tests for IPXXD, the access probe may penetrate to its full length, but the stop face shall not fully penetrate through the opening. Table 1 Figure 1
Appears in 1 contract
Samples: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles