ACCEPTANCE TEST Sr Sample Clauses

ACCEPTANCE TEST Sr. No. Test to be done Reference BIS / Document 1 Measurement of power- frequency voltage on the arrester at the reference current. As per IEC 60099-4 Ed.3 clause no. 9.2.1.a or IS:3070 part3 cl.6.2.8 2 Lightning impulse residual voltage on the arrester at nominal discharge current As per IEC 60099-4 Ed.3 clause no. 9.2.1.b or IS:3070 part3 cl.6.4. and table 8 3 Partial Discharge Test (Both in Dry and Wet condition) As per IEC60099 part4 cl.9.1
AutoNDA by SimpleDocs

Related to ACCEPTANCE TEST Sr

  • ACCEPTANCE TESTS 11.1 If the Contract provides acceptance tests for Goods and/or the result of Services after their completion and/or delivery to the Purchaser, the acceptance shall only be considered as definitive when such tests have demonstrated the compliance of the Goods and/or the result of the Services to the requirements in the Contract.

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.

  • Acceptance/Performance Test 4.7.1 Prior to synchronization of the Power Project, the SPD shall be required to get the Project certified for the requisite acceptance/performance test as may be laid down by Central Electricity Authority or an agency identified by the central government to carry out testing and certification for the solar power projects.

  • INSPECTION, ACCEPTANCE AND REJECTION a. All Goods will be subject to Mercy Corps' inspection and testing (which may be done by a third party authorized by Mercy Corps), at any time and place, including the period of manufacture/production/creation and before final acceptance. If Mercy Corps inspects or tests at Supplier's premises, Supplier, without additional charge, will provide all reasonable facilities and assistance for the safety and convenience of Mercy Corps' inspectors. No inspection or testing done or not done before final inspection and acceptance will relieve Supplier from responsibility for defects or for other failure to meet the requirements of this Agreement. Notwithstanding any prior inspections or payments made, all Goods will be subject to final inspection and acceptance at the Delivery Location within a reasonable time after delivery (but in no event, less than three days after the date of delivery).

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • Acceptance Procedure Lessor hereby authorizes one or more employees of the related Lessee, to be designated by such Lessee, as the authorized representative or representatives of Lessor to accept delivery on behalf of Lessor of that Leased Property identified on the applicable Funding Request. Each Lessee hereby agrees that such acceptance of delivery by such authorized representative or representatives and the execution and delivery by such Lessee on each Closing Date for property to be leased hereunder of a Lease Supplement in substantially the form of Exhibit A hereto (appropriately completed) shall, without further act, constitute the irrevocable acceptance by such Lessee of that Leased Property which is the subject thereof for all purposes of this Lease and the other Operative Documents on the terms set forth therein and herein, and that such Leased Property, together with, in the case of Land, any Building or other improvements thereon or to be constructed thereon pursuant to the Construction Agency Agreement, shall be deemed to be included in the leasehold estate of this Lease and shall be subject to the terms and conditions of this Lease as of such Closing Date. The demise and lease of each Building pursuant to this Section 2.2 shall include any additional right, title or interest in such Building which may at any time be acquired by Lessor, the intent being that all right, title and interest of Lessor in and to such Building shall at all times be demised and leased to the related Lessee hereunder.

  • ACCEPTANCE STANDARDS Inspection and acceptance/rejection of products shall be made within thirty (30) days of receipt or upon completion of installation should that installation period extend beyond thirty

  • Acceptance Process All deliverables must be received and accepted in writing by Department’s Grant Manager before payment. The Grantee shall work diligently to correct all deficiencies in the deliverable that remain outstanding, within a reasonable time at Grantee’s expense. If Department’s Grant Manager does not accept the deliverables within 30 days of receipt, they will be deemed rejected.

  • Laboratory Testing All laboratories selected by UPS Freight for analyzing Controlled Substances Testing will be HHS certified.

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester.