AFEL Sample Clauses

AFEL. The power of the unwanted emissions consists of out-of-band emissions and spurious emissions. The out-of-band emissions requirement for the base station (BS) transmitter is specified in terms of the Operating Band Unwanted Emissions. ▪ Operating band class: n78 (3300 – 3800 MHz) ▪ BS type: 1-C, 1-H and 1-O, Wide area BS category BThe unit of power: dBW/MHz EIRP For 5G Base Stations operating under passive antenna systems, antenna gain of 17 dBi is added as the EIRP requirement for AFEL. AFELEIRP (dBW) = Basic Unwanted Emissions Limits (dBW) + XXxx (dBi) where XXxx = 17 dBi The AFEL limits for each Management Right are listed in Table 2. Table 2 AFEL limits for 3.5 GHz Early Access spectrum Frequency (MHz) Maximum Level (dBW) E.I.R.P. < 3550 -43 3550 -28 f_low – 10 -28 f_low – 10 -17 f_low – 5 -17 f_low -10 f_high -10 f_high + 5 -17 f_high + 10 -17 f_high + 10 -28 3840 -28 ≥ 3840 -43 f_low: The lower edge frequency of the Management Right f_high: The upper edge frequency of the Management Right A graphic representation of the AFEL is shown in Figure 3.
AutoNDA by SimpleDocs

Related to AFEL

  • County’s Project Manager Note: The written approval of substituted A-E Key Personnel is for departmental use only and shall not be used for auditing purposes outside OC Public Works or other County department.

  • County Project Manager The County shall appoint a Project Manager to act as liaison with Contractor during the term of this Contract. The County’s Project Manager shall coordinate the activities of the County staff assigned to work with the Contractor.

  • Purchase Order and Sales Contact Email Please enter a valid email address that will definitely reach the Purchase Order and Sales Contact. 2 xxxxx@xxxxxxxxxxxxxx.xxx Purchase Order and Sales Contact Phone Numbers only, no symbols or spaces (Ex. 8668398477). The system will auto-populate your entry with commas once submitted which is appropriate and expected (Ex. 8,668,398,477). 2 3 9566826005 Company Website Company Website (Format - xxx.xxxxxxx.xxx) 4 xxx.xxxxxxxxxxxxxx.xxx Entity D/B/A's and Assumed Names You must confirm that you are responding to this solicitation under your legal entity name. Go now to your Supplier Profile in this eBid System and confirm that your profile reflects your "Legal Name" as it is listed on your W9. In this question, please identify all of your entity's assumed names and D/B/A's. Please note that you will be identified publicly by the Legal Name under which you respond to this solicitation unless you organize otherwise with TIPS after award. 5 Superior Alarms Primary Address Primary Address 2 6 000 Xxx Xxxxxx Primary Address City Primary Address City 7 McAllen Primary Address State Primary Address State (2 Digit Abbreviation) 2 8 TX Primary Address Zip Primary Address Zip 9 78501 Search Words Identifying Vendor Please list all search words and phrases to be included in the TIPS database related to your entity. Do not list words which are not associated with the bid category/scope (See bid title for general scope). This will help users find you through the TIPS website search function. You may include product names, manufacturers, specialized services, and other words associated with the scope of this solicitation. security, monitoring, services, inspections, life safety, IP, surveillance, fire, IP cameras, access control, telephone, networking, GPS, fire alarm, voice evacuation, mass notification, panic, internet, and CCTV systems. Certification of Vendor Residency (Required by the State of Texas) Does Vendor's parent company or majority owner:

  • Geotechnical Services Engineer will obtain all necessary subsurface investigations, tests, reports, and perform related surveys.

  • Project Manager The term “Project Manager” refers to the employee of the State who has been assigned responsibility for overseeing and managing the proper and timely implementation of the project.

  • Design Development Phase Services 3.3.1 Based on the Owner’s approval of the Schematic Design Documents, and on the Owner’s authorization of any adjustments in the Project requirements and the budget for the Cost of the Work, the Architect shall prepare Design Development Documents for the Owner’s approval. The Design Development Documents shall illustrate and describe the development of the approved Schematic Design Documents and shall consist of drawings and other documents including plans, sections, elevations, typical construction details, and diagrammatic layouts of building systems to fix and describe the size and character of the Project as to architectural, structural, mechanical and electrical systems, and other appropriate elements. The Design Development Documents shall also include outline specifications that identify major materials and systems and establish, in general, their quality levels.

  • Millwright Xxxxx be to assist and work under the direction and instructions I or A. He will work alone at times performing assignments in keeping with his training. During the course of his year, training must become proficient in good practices in the areas of fitting, aligning, lubricating and the operation of all shop tools and machines. In addition to the foregoing, he will be exposed to and the process of learning techniques required in trouble shooting key production machinery, pipe fitting, basic welding and machining but not be expected to display a high degree of proficiency in these areas at this point. Millwright Must be capable of performing the tasks of fittings, aligning, lubricating an able to operate all shop tools and machines. Must under direction become proficient in basic welding and pipe fitting as well as dismantling and reassembly of plant equipment. Under direction,will continueto develop skills in trouble shooting all plant equipment and improve his skills at machining part and be exposed to basic principles of hydraulics and pneumatic. He may work alone frequently, but occasionally will require direction and instructions form Millwright I or A. Millwright 11: be capable, without direction of fitting, aligning and lubrication and taking apart and reassembling plant equipment. In addition, is expected to be able to weld, operate shop tools and do pipe fitting as required. Must under direction, become proficient at effective methods of trouble shooting and repairing hydraulic, pneumatic and mechanical faults in plant machinery. I: Must be capable without direction of performing all practices under Xxxxxxxxxx Must under directionbecomeproficient at reading and understanding blueprints, all phases of installing new equipment, laying out hydraulic and mechanical drives and meet speed and power requirements correctly. Xxxxxxxxxx "A": Must he capable without direction, of performing all under Xxxxxxxxxx X, and Must take full responsibility for work done by himself or his assistant. Must he in possession of a Millwright Certificate or a Machinist Certificate or Welder Certificate. Millwrightspresently employed in this classification will not be required to have a Certificate.

  • Purchase Order and Sales Contact Name Please identify the individual who will be responsible for receiving and processing purchase orders and sales under the TIPS Contract.

  • Geotechnical Engineer « »« » « » « » « » « »

  • Contractor Project Manager The Contractor Project Manager shall serve, from the Effective Date, as the Contractor project manager and primary Contractor representative under this Agreement. The Contractor Project Manager shall (i) have overall responsibility for managing and coordinating the performance of Contractor’s obligations under this Agreement, including the performance of all Subcontractors; and (ii) be authorized to act for and bind Contractor and Subcontractors in connection with all aspects of this Agreement. The Contractor Project Manager shall respond promptly and fully to all inquiries from the JBE Project Manager.

Time is Money Join Law Insider Premium to draft better contracts faster.