Air Lines and Fittings Sample Clauses

Air Lines and Fittings. Air lines, except necessary flexible lines, shall conform to the installation and material requirements of SAE Standard J1149 for copper tubing with standard, brass, flared or ball sleeve fittings, or SAE Standard J844 for nylon tubing if not subject to temperatures over 200° F. Nylon tubing shall be installed in accordance with the following color-coding standards: Green – Indicates primary brakes and supply Red – Indicates secondary brakes Xxxxx – Indicates parking brake Yellow – Indicates compressor governor signal Black – Indicates accessories ALL Nylon air lines shall be installed exclusively utilizing “push to connect” type fittings. Line supports shall prevent movement, flexing, tension strain, and vibration. Copper lines shall be supported to prevent the lines from touching one another or any component of the vehicle. Before installation, copper lines shall be pre-bent on a fixture that prevents tube flattening or excessive local strain. Copper lines shall be bent only once at any point, including pre- bending and installation. Rigid lines shall be supported at no more than 5-foot intervals. Nylon air lines may be grouped only with nylon air lines and shall be supported at 2.5-foot intervals or less. The compressor discharge line between power plant and body-mounted equipment shall be flexible convoluted copper or stainless steel line, or may be flexible Teflon hose with a braided stainless steel xxxx. Flexible hoses shall be as short as practicable and individually supported. They shall not touch one another or any part of the vehicle except for the supporting grommets. Flexible lines shall be supported at 2-foot intervals or less. A rigid tubing cooling coil shall be installed in the air stream before the air dryer. Air lines shall be clean before installation and shall be installed to minimize air leaks. All air lines shall be sloped toward a reservoir, to the extent possible, and routed to prevent water traps. Grommets or insulated clamps shall protect the air lines at all points where they pass near understructure components. Bulkhead connector shall be installed at all points where air lines pass through a bulkhead, panel or floor.
AutoNDA by SimpleDocs

Related to Air Lines and Fittings

  • FIXTURES AND FITTINGS 7.13.1 Not to remove any of the Fixtures and Fittings from the Premises to store the same in the loft, basement or garage (if any) without obtaining the Landlord’s prior written consent, such consent not to be unreasonably withheld, and then to ensure that any such items are stored safely and upon vacating the Premises, to leave the same in the places in which they were on the Commencement Date.

  • Accessories, Spare Parts and Tools 1. In determining whether all the non-originating materials used in the production of a good undergo the applicable change in tariff classification or a specific manufacturing or processing operation set out in Annex 2, accessories, spare parts or tools delivered with the good that form part of the good's standard accessories, spare parts or tools, shall be disregarded, provided that:

  • Installation Where installation is required, Contractor shall be responsible for placing and installing the product in the required locations at no additional charge, unless otherwise designated on the Contract or purchase order. Contractor’s authorized product and price list shall clearly and separately identify any additional installation charges. All materials used in the installation shall be of good quality and shall be free of defects that would diminish the appearance of the product or render it structurally or operationally unsound. Installation includes the furnishing of any equipment, rigging, and materials required to install or replace the product in the proper location. Contractor shall protect the site from damage and shall repair damages or injury caused during installation by Contractor or its employees or agents. If any alteration, dismantling, excavation, etc., is required to achieve installation, the Contractor shall promptly restore the structure or site to its original condition. Contractor shall perform installation work so as to cause the least inconvenience and interference with Customers and with proper consideration of others on site. Upon completion of the installation, the location and surrounding area of work shall be left clean and in a neat and unobstructed condition, with everything in satisfactory repair and order.

  • Installation and Use You may install and use the Software only for the number of licenses acquired by you. In order to exercise your rights to the Software under this Agreement, you must activate your copy of the Software in the manner described during the launch sequence.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Equipment and Facilities For On-Site Courses, you will supply the facility and equipment as set forth at xxx.xxxxxx.xxx/xxxxxxxx/xxxxxxxxx/xxxxxxxxxxxx.xxxx. If Red Hat agrees to provide the training facilities and hardware, you will be liable for any loss or destruction of this equipment and hardware used in connection with the Training.

  • Services and Facilities The Procuring Entity shall make available to the Service Provider the Services and Facilities listed under Appendix F.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

  • Access to Network Interface Device (NID 2.4.3.1. Due to the wide variety of NIDs utilized by BellSouth (based on subscriber size and environmental considerations), Mpower may access the on-premises wiring by any of the following means: BellSouth shall allow Mpower to connect its loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premise. Mpower agrees to install compatible protectors and test jacks and to maintain the protection system and equipment and to indemnify BellSouth pursuant to Section 8 of the General Terms and Conditions of this Agreement.

  • Cutting, Patching, and Fitting The Contractor shall do all cutting, patching, and fitting of the Work that may be required to make its several parts come together properly and fit.

Time is Money Join Law Insider Premium to draft better contracts faster.