AIRLOCK HATCHES Sample Clauses

AIRLOCK HATCHES. The hatches shall be either of a type that remains closed under the pressure of the airlock or shall be fitted with locks preventing opening until the pressures are balanced. The personnel airlock hatch between the cutterhead chamber and the transfer chamber shall withstand pressure from both sides if the emergency access compartment is connected to it; otherwise only the hatch on the working chamber side need comply with this requirement. The hatch providing access to the cutterhead chamber shall open into the cutterhead chamber. [STAMP] Bouygues TP Sheung Shui to Xxxx Tau Tunnels July 0000 XXXX PLp TECHNICAL SPECIFICATIONS FOR TBM & BACKUP
AutoNDA by SimpleDocs

Related to AIRLOCK HATCHES

  • No Light, Air or View Easement Any diminution or shutting off of light, air or view by any structure which may be erected on lands adjacent to or in the vicinity of the Building shall in no way affect this Lease or impose any liability on Landlord.

  • Cockpit (a) Fairing panels shall be free of stains and cracks, will be clean secure and repainted as necessary;

  • Restrooms The restrooms, toilets, urinals, vanities and the other apparatus shall not be used for any purpose other than that for which they were constructed, and no foreign substance of any kind whatsoever shall be thrown therein. The expense of any breakage, stoppage or damage resulting from the violation of this rule shall be borne by the Tenant whom, or whose employees or invitees, shall have caused it.

  • Building Directory A directory for the Building will be provided for the display of the name and location of tenants. Landlord reserves the right to approve any additional names Tenant desires to place in the directory and, if so approved, Landlord may assess a reasonable charge for adding such additional names.

  • Directory The bulletin board or directory of the Building will be provided exclusively for the display of the name and location of tenants and Landlord reserves the right to exclude any other names therefrom.

  • Wash all machine-washable bedding, drapes, and clothing, on the hottest water temperature and dry on the highest heat setting. Items that cannot be washed must be taken to a dry cleaner who MUST be informed of the issue. You must safely discard ALL items that cannot be decontaminated.

  • Configuration The configuration for the Purchase Right Aircraft will be the Detail Specification for Model 767-3S2F aircraft at the revision level in effect at the time of the Supplemental Agreement. Such Detail Specification will be revised to include (i) changes required to obtain required regulatory certificates and (ii) other changes as mutually agreed upon by Boeing and Customer.

  • Generator Subject to the provisions of this Section 29.36, Tenant shall be entitled to install, operate and maintain a generator and any other equipment related thereto, including, without limitation, a fuel system, wiring and shaft space (“Generator”) next to the Building at Tenant’s sole cost and expense (without paying any additional fee or rental to Landlord for the use thereof). Prior to the installation of the Generator, Tenant shall inspect the proposed location to determine a suitable location for the Generator, and Tenant shall submit written plans and specifications relative to the type, size and proposed location (including any proposed screening) of the Generator to Landlord for its review and written approval. Tenant shall be solely responsible for the cost of acquisition, installation, operation, and maintenance of the Generator; and Tenant shall install, maintain and operate the Generator in accordance with all federal, state, and local laws, statutes, ordinances, rules and regulations, including without limitation, obtaining and maintaining any and all permits, approvals and licenses required to install and operate the Generator by any governmental authority having jurisdiction. Landlord and Tenant agree that, upon the expiration of earlier termination of the Lease Term, Tenant shall not be required to remove the Generator, any associated cabling, wiring and screening or other improvements. Tenant shall not be entitled to grant or assign to any third party (other than a permitted assignee of Tenant’s rights under the Lease or a permitted subtenant relative to the Premises (or a portion thereof)) the right to use the Generator without Landlord’s prior written consent (which consent may be granted or withheld in Landlord’s discretion). Upon reasonable advance notice to Tenant (and provided Landlord reasonably coordinates with Tenant and provides an alternate source of backup generator capacity during said transition), Landlord shall be entitled to cause the Generator to be moved to another location near the Building, at Landlord’s cost and expense. Tenant shall pay all personal property taxes on the Generator. Tenant shall also pay any increases in the real property taxes of the Building due to the installation of the Generator within thirty (30) days of receipt of notice from Landlord which includes proof of such increase in taxes. Tenant’s indemnity obligations under Section 5.4.1.5 of the Lease, relating to the use of Hazardous Materials, shall apply to the use and operation of the Generator. Finally, Tenant’s insurance obligations under Section 10.3 of the Lease shall apply to the Generator.

  • Site Plan The Landlord covenants that the Center is or shall be developed in accordance with the Site Plan and that it shall be used as a retail shopping center throughout the term of this Lease. The Landlord may not modify or replace the Site Plan without the prior written consent of the Tenant, which consent shall not be unreasonably withheld or delayed. No such modification or replacement shall (i) reduce the ratio of parking spaces to gross leasable area of buildings in the Center shown on the Site Plan, (ii) reduce or rearrange the parking spaces cross-hatched on the Site Plan, (ii) interfere with truck access to the loading doors of the Premises, (iv) interfere with customer access to the Premises or the parking areas closest to the Premises, (v) interfere with the visibility of the Premises from the roads providing direct access to the Center or (vi) result in the construction of any buildings in the area designated "No Build Area" on the Site Plan.

  • Office Location During the Term, the Executive's services hereunder shall be performed at the offices of the Company, which shall be within a twenty five (25) mile radius of New York, NY, subject to necessary travel requirements to the Company’s offices in Toronto, Canada and other MDC Group company locations in order to carry out his duties in connection with his position hereunder.

Time is Money Join Law Insider Premium to draft better contracts faster.