Authorities for Pseudo Sample Clauses

Authorities for Pseudo. Tied Units into LG&E/KU and out of TVA Balancing Authority Areas. TVA shall be the Native TOP, Native BA, and only RC (Native and Attaining), responsible for transmission related congestion (SOLs and IROLs) on the transmission system where the pseudo-tied units are physically connected with the TVA transmission system and pseudo-tied into LG&E/KU. LG&E/KU shall be the Attaining BA, responsible for the commitment and dispatch of each pseudo-tied unit or the pseudo-tied portion of a partially pseudo-tied unit physically located within the TVA BAA and TVA RC Area that are pseudo-tied into the LG&E/KU BAA. LG&E/KU shall be the Attaining BA for all of the MW of such generation units that are pseudo-tied out of the TVA BAA and into the LG&E/KU BAA.
AutoNDA by SimpleDocs
Authorities for Pseudo. Tied Units into LG&E/KU and out of PJM Balancing Authority Areas. PJM shall be the Native TOP, Native BA, and Native RC, responsible for transmission related congestion (SOLs and IROLs) on the transmission system where the pseudo-tied units are physically connected with the PJM transmission system and pseudo-tied into LGE/KU. LG&E/KU shall be the Attaining BA responsible for commitment and dispatch of each pseudo-tied unit or the pseudo-tied portion of a partially pseudo-tied unit physically located within the PJM BAA and RC Area. LG&E/KU shall be the Attaining BA and TVA shall be the Attaining RC for all of the MWs of such generating units that are pseudo-tied out of the PJM BAA and into the LG&E/KU BAA.
Authorities for Pseudo. Tied Units into TVA and out of PJM Balancing Authority Area. PJM will be the Native TOP, Native BA, and Native RC, responsible for transmission related congestion (SOLs and IROLs) on the transmission system where the pseudo-tied units are physically connected with the PJM system and pseudo-tied into TVA. TVA will be the Attaining RC and BA responsible for commitment and dispatch of each pseudo-tied unit or the pseudo- tied portion of a partially pseudo-tied unit physically located within the TVA BAA and RC Area. TVA will be the Attaining BA and Attaining RC for all of the MW of such generation units that are pseudo-tied out of the PJM BAA and into the TVA BAA.

Related to Authorities for Pseudo

  • Competent Authorities The Parties shall inform each other about the structure, organisation and division of competences of their competent authorities during the first meeting of the Sanitary and Phytosanitary Sub-Committee referred to in Article 65 of this Agreement ("SPS Sub-Committee"). The Parties shall inform each other of any change of the structure, organisation and division of competences, including of the contact points, concerning such competent authorities.

  • Developer Authority Consistent with Good Utility Practice and this Agreement, the Developer may take whatever actions or inactions with regard to the Large Generating Facility or the Developer Attachment Facilities during an Emergency State in order to (i) preserve public health and safety, (ii) preserve the reliability of the Large Generating Facility or the Developer Attachment Facilities, (iii) limit or prevent damage, and (iv) expedite restoration of service. Developer shall use Reasonable Efforts to minimize the effect of such actions or inactions on the New York State Transmission System and the Connecting Transmission Owner’s Attachment Facilities. NYISO and Connecting Transmission Owner shall use Reasonable Efforts to assist Developer in such actions.

  • AUTHORITIES This agreement is entered into pursuant to the following authorities:

  • Authority’s right to take remedial measures

  • PROPER AUTHORITY Each Party represents and warrants that the person executing this Contract on its behalf has full power and authority to enter into this Contract.