Breaker. Breaker failure protection for the 69kV breaker will trip the appropriate adjacent breakers and send direct transfer trip to Connecting Transmission Owner’s Cobleskill and Marshville Substations. For loss of SF6, the breaker must trip and block close. (Note: When the facility’s interrupter fails to interrupt for internal station faults and loss of SF6 condition, the Interconnection Customer is not to rely on the Connecting Transmission Owner’s 69kV system for remote backup.) DTT receive from Cobleskill and Marshville Substations will be required to trip the Interconnection Customer’s 69kV breaker for a line relay operation or breaker failure at Cobleskill and Marshville Substations. Interconnection Customer will provide On/Off switches for the DTT schemes.
Appears in 5 contracts
Samples: Standard Small Generator Interconnection Agreement, Standard Small Generator Interconnection Agreement, Service Agreement
Breaker. Breaker failure protection for the 69kV 115kV breaker will trip the appropriate adjacent breakers and send direct transfer trip to Connecting Transmission Owner’s Cobleskill Inghams and Marshville Substations. For loss of SF6, the breaker must trip and block close. (Note: When the facility’s interrupter fails to interrupt for internal station faults and loss of SF6 condition, the Interconnection Customer is not to rely on the Connecting Transmission Owner’s 69kV 115kV system for remote backup.) DTT receive from Cobleskill Inghams and Marshville Substations will be required to trip the Interconnection Customer’s 69kV 115kV breaker for a line relay operation or breaker failure at Cobleskill Inghams and Marshville Substations. Interconnection Customer will provide On/Off switches for the DTT schemes.
Appears in 4 contracts
Samples: Standard Small Generator Interconnection Agreement, Standard Small Generator Interconnection Agreement, Standard Small Generator Interconnection Agreement
Breaker. SERVICE AGREEMENT NO. 2600 Breaker failure protection for the 69kV 115kV breaker will trip the appropriate adjacent breakers and send direct transfer trip to Connecting Transmission Owner’s Cobleskill Inghams and Marshville Substations. For loss of SF6, the breaker must trip and block close. (Note: When the facility’s interrupter fails to interrupt for internal station faults and loss of SF6 condition, the Interconnection Customer is not to rely on the Connecting Transmission Owner’s 69kV 115kV system for remote backup.) DTT receive from Cobleskill Inghams and Marshville Substations will be required to trip the Interconnection Customer’s 69kV 115kV breaker for a line relay operation or breaker failure at Cobleskill Inghams and Marshville Substations. Interconnection Customer will provide On/Off switches for the DTT schemes.
Appears in 2 contracts
Samples: Service Agreement, Service Agreement
Breaker. 2-2 SERVICE AGREEMENT NO. 2600 Breaker failure protection for the 69kV 115kV breaker will trip the appropriate adjacent breakers and send direct transfer trip to Connecting Transmission Owner’s Cobleskill Inghams and Marshville Substations. For loss of SF6, the breaker must trip and block close. (Note: When the facility’s interrupter fails to interrupt for internal station faults and loss of SF6 condition, the Interconnection Customer is not to rely on the Connecting Transmission Owner’s 69kV 115kV system for remote backup.) DTT receive from Cobleskill Inghams and Marshville Substations will be required to trip the Interconnection Customer’s 69kV 115kV breaker for a line relay operation or breaker failure at Cobleskill Inghams and Marshville Substations. Interconnection Customer will provide On/Off switches for the DTT schemes.
Appears in 1 contract