Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety
Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.
RAI MDS Without limiting the foregoing, the HSP (1) will conduct quarterly assessments of Residents, and all other assessments of Residents required by the RAI MDS Tools, using the RAI MDS Tools; (2) will ensure that the RAI MDS Tools are used correctly to produce an accurate assessment of the HSP’s Residents (“RAI MDS Data”);
Vendor Encouraging Members to bypass TIPS agreement Encouraging entities to purchase directly from the Vendor or through another agreement, when the Member has requested using the TIPS cooperative Agreement or price, and thereby bypassing the TIPS Agreement is a violation of the terms and conditions of this Agreement and will result in removal of the Vendor from the TIPS Program.
Multi-Member The Members, or their designees, shall maintain complete and accurate records and books of the Company’s transactions in accordance with generally accepted accounting principles. The Company shall furnish each Member, within seventy-five days after the end of each fiscal year, an annual report of the Company including a balance sheet, a profit and loss statement a capital account statement; and the amount of such Member’s share of the Company’s income, gain, losses, deductions and other relevant items for federal income tax purposes. The Company shall prepare all Federal, State and local income tax and information returns for the Company, and shall cause such tax and information returns to be timely filed. Within seventy-five days after the end of each fiscal year, the Company shall forward to each person who was a Member during the preceding fiscal year a true copy of the Company’s information return filed with the Internal Revenue Service for the preceding fiscal year. All elections required or permitted to be made by the Company under the Internal Revenue Code, and the designation of a tax matters partner pursuant to Section 6231(a)(7) of the Internal Revenue Code for all purposes permitted or required by the Code, shall be made by the Company by the affirmative vote or consent of Members holding a majority of the Members’ Percentage Interests. Upon request, the Company shall furnish to each Member, a current list of the names and addresses of all of the Members of the Company, and any other persons or entities having any financial interest in the Company.
Foreign-Owned Companies in Connection with Critical Infrastructure If Texas Government Code, Section 2274.0102(a)(1) (relating to prohibition on contracts with certain foreign-owned companies in connection with critical infrastructure) is applicable to this Contract, pursuant to Government Code Section 2274.0102, Contractor certifies that neither it nor its parent company, nor any affiliate of Contractor or its parent company, is: (1) majority owned or controlled by citizens or governmental entities of China, Iran, North Korea, Russia, or any other country designated by the Governor under Government Code Section 2274.0103, or (2) headquartered in any of those countries.
Joint Venture, Consortium or Association 6.1 If the Supplier is a joint venture, consortium, or association, all of the parties shall be jointly and severally liable to the Procuring Entity for the fulfilment of the provisions of the Contract and shall designate one member of the joint venture, consortium, or association to act as a leader with authority to bind the joint venture, consortium, or association. The composition or the constitution of the joint venture, consortium, or association shall not be altered without the prior written consent of the Procuring Entity.
Member Access to Vendor Proposal Notwithstanding any other information provided in this solicitation or Vendor designation of certain documentation as confidential or proprietary, Vendor’s acceptance of this TIPS Contract constitutes Vendor’s consent to the disclosure of Vendor’s comprehensive proposal, including any information deemed confidential or proprietary, to TIPS Members. The proposing Vendor agrees that TIPS shall not be responsible or liable for any use or distribution of information or documentation by TIPS Members or any other party. By submitting this proposal, Vendor certifies the foregoing.
Information Technology Enterprise Architecture Requirements If this Contract involves information technology-related products or services, the Contractor agrees that all such products or services are compatible with any of the technology standards found at xxxxx://xxx.xx.xxx/iot/2394.htm that are applicable, including the assistive technology standard. The State may terminate this Contract for default if the terms of this paragraph are breached.
Sub-Advisor Compliance Policies and Procedures The Sub-Advisor shall promptly provide the Trust CCO with copies of: (i) the Sub-Advisor’s policies and procedures for compliance by the Sub-Advisor with the Federal Securities Laws (together, the “Sub-Advisor Compliance Procedures”), and (ii) any material changes to the Sub-Advisor Compliance Procedures. The Sub-Advisor shall cooperate fully with the Trust CCO so as to facilitate the Trust CCO’s performance of the Trust CCO’s responsibilities under Rule 38a-1 to review, evaluate and report to the Trust’s Board of Trustees on the operation of the Sub-Advisor Compliance Procedures, and shall promptly report to the Trust CCO any Material Compliance Matter arising under the Sub-Advisor Compliance Procedures involving the Sub-Advisor Assets. The Sub-Advisor shall provide to the Trust CCO: (i) quarterly reports confirming the Sub-Advisor’s compliance with the Sub-Advisor Compliance Procedures in managing the Sub-Advisor Assets, and (ii) certifications that there were no Material Compliance Matters involving the Sub-Advisor that arose under the Sub-Advisor Compliance Procedures that affected the Sub-Advisor Assets. At least annually, the Sub-Advisor shall provide a certification to the Trust CCO to the effect that the Sub-Advisor has in place and has implemented policies and procedures that are reasonably designed to ensure compliance by the Sub-Advisor with the Federal Securities Laws.