Communication of Planned Maintenance or Forced Outage Sample Clauses

Communication of Planned Maintenance or Forced Outage. 16.3.1 Notices to be given by the Offtaker under this Clause 16 shall be validly given if transmitted by e-mail to the Maintenance or Outage Person using the e-mail address specified at Schedule 1 (Project Specific Information).‌
AutoNDA by SimpleDocs

Related to Communication of Planned Maintenance or Forced Outage

  • Maintenance Outages If Seller reasonably determines that it is necessary to schedule a Maintenance Outage, Seller shall notify Buyer of the proposed Maintenance Outage at least five (5) days before the outage begins (or such shorter period to which Buyer may reasonably consent in light of then existing conditions). Upon such notice, the Parties shall plan the Maintenance Outage to mutually accommodate the reasonable requirements of Seller and the service obligations of Buyer; provided, however, that, unless Buyer otherwise consents, such consent not to be unreasonably withheld, no Maintenance Outage may be scheduled between the hour ending 0700 through the hour ending 2200, Monday through Saturday, during the time period commencing on May 15 and concluding on September 15. Notice of a proposed Maintenance Outage shall include the expected start date and time of the outage, the amount of Capacity of the Facility that will not be available, and the expected completion date and time of the outage. Seller shall give Buyer notice of the Maintenance Outage as soon as Seller determines that the Maintenance Outage is necessary. Buyer shall promptly respond to such notice and may request reasonable modifications in the schedule for the outage. Seller shall use all reasonable efforts to comply with any request to modify the schedule for a Maintenance Outage. Seller shall notify Buyer of any subsequent changes in Capacity available to Buyer or any changes in the Maintenance Outage completion date and time. As soon as practicable, any notifications given orally shall be confirmed in writing. Seller shall take all reasonable measures and exercise its best efforts in accordance with Prudent Electrical Practices to minimize the frequency and duration of Maintenance Outages.

  • Planned Maintenance (a) Sellers may designate up to twenty (20) Days of Planned Maintenance on Sellers’ Facilities during each Contract Year. Sellers shall be entitled to reduce (including down to zero (0)) its Gas scheduling under Clause 8 and Exhibit 3 for each Day of Planned Maintenance.

  • SYSTEM CHANGES AND MAINTENANCE/SUPPORT The Contractor shall give a minimum of 5 business days advance Written notice to the designated Authorized User contact of any upgrades, system changes and Maintenance/support actions that may potentially impact services described in the Authorized User Agreement. Upgrades, system changes, and Maintenance/support actions which are required by system vulnerabilities or emergency situations shall be carried out by the Contractor to protect the system. Authorized Users shall be notified by the Contractor as soon as possible after the change has taken place. Contractor shall provide documentation of upgrades, system changes and Maintenance/support actions upon request from an Authorized User. EXPIRATION, TERMINATION OR SUSPENSION OF SERVICES Return of Data The Contractor shall return Data in a format agreed upon within the Authorized User Agreement or as agreed to with the Authorized User. This can, if specified within the Authorized User Agreement, be carried out by providing application programmable interface or other such efficient electronic tools. The Contractor must certify all Data has been removed from its system and removed from backups within timeframes established in the Authorized User Agreement or as agreed to with the Authorized User. Suspension of Services During any period of suspension of service, the Authorized User shall have full access to all Data at no charge. This can, if specified within the Authorized User Agreement, be carried out by providing an application programmable interface or other such efficient electronic tools. The Contractor shall not take any action to erase and/or withhold any Authorized User Data, except as directed by the Authorized User. Expiration or Termination of Services Upon expiration or termination of an Authorized User Agreement, the Authorized User shall have full access to all Data for a period of 60 calendar days. Unless noted in the original Authorized User Agreement, this period will be covered at no charge. This can, if specified within the Authorized User Agreement, be carried out by providing application programmable interface or other such efficient electronic tools. During this period, the Contractor shall not take any action to erase and/or withhold any Data, except as directed by the Authorized User. An Authorized User shall have the right to specify a period in excess of 60 calendar days in its RFQ. SECURE DATA DISPOSAL When requested by the Authorized User, the Contractor shall destroy Data in all of its forms, including all back-ups. Data shall be permanently deleted and shall not be recoverable, according ITS Policy S13-003 Sanitization/Secure Disposal or successor and S14-003 Information Security Controls or successor. Certificates of destruction, in a form acceptable to the Authorized User, shall be provided by the Contractor to the Authorized User.

  • CONTRACTOR RESPONSIBILITY FOR SYSTEM AGENCY’S TERMINATION COSTS If the System Agency terminates the Contract for cause, the Contractor shall be responsible to the System Agency for all costs incurred by the System Agency and the State of Texas to replace the Contractor. These costs include, but are not limited to, the costs of procuring a substitute vendor and the cost of any claim or litigation attributable to Contractor’s failure to perform any Work in accordance with the terms of the Contract.

  • Unscheduled Maintenance Unscheduled maintenance may be required to resolve issues that are critical for Customer and/or performance of the Cloud Services. Druva will use its commercially reasonable efforts to notify Customer at least six (6) hours prior to the unscheduled maintenance.

  • DEVELOPMENT OR ASSISTANCE IN DEVELOPMENT OF SPECIFICATIONS REQUIREMENTS/ STATEMENTS OF WORK Firms and/or individuals that assisted in the development or drafting of the specifications, requirements, statements of work, or solicitation documents contained herein are excluded from competing for this solicitation. This shall not be applicable to firms and/or individuals providing responses to a publicly posted Request for Information (RFI) associated with a solicitation.

  • Uncontrollable Forces Tariff Provisions Section 14.1 of the CAISO Tariff shall be incorporated by reference into this Agreement except that all references in Section 14.1 of the CAISO Tariff to Market Participants shall be read as a reference to the Participating Generator and references to the CAISO Tariff shall be read as references to this Agreement.

  • Maintenance Scheduling The NTO shall schedule maintenance of its facilities designated as NTO Transmission Facilities Under ISO Operational Control and schedule any outages (other than forced transmission outages) of said transmission system facilities in accordance with outage schedules approved by the ISO. The NTO shall comply with maintenance schedules coordinated by the ISO, pursuant to this Agreement, for NTO Transmission Facilities Under ISO Operational Control. The NTO shall be responsible for providing notification of maintenance schedules to the ISO for NTO Transmission Facilities Requiring ISO Notification. The NTO shall provide notification of maintenance schedules to affected Transmission Owners for NTO Transmission Facilities Requiring ISO Notification and Local Area Transmission Facilities pursuant to Section 3.5.3 of the ISO Services Tariff.

  • Notifications of Outages and Maintenance In the event that a Registry Operator plans maintenance, it will provide notice to the ICANN emergency operations department, at least, twenty-­‐four (24) hours ahead of that maintenance. ICANN’s emergency operations department will note planned maintenance times, and suspend Emergency Escalation services for the monitored services during the expected maintenance outage period. If Registry Operator declares an outage, as per its contractual obligations with ICANN, on services under a service level agreement and performance requirements, it will notify the ICANN emergency operations department. During that declared outage, ICANN’s emergency operations department will note and suspend emergency escalation services for the monitored services involved.

  • System Maintenance The Trust understands that USBFS will perform periodic maintenance to the System(s), which may cause temporary service interruptions. To the extent possible, USBFS shall notify the Trust of all planned outages and will perform any necessary maintenance during non-business hours.

Time is Money Join Law Insider Premium to draft better contracts faster.