Cryo and Earth Storable Gas Systems (CESGS Sample Clauses

Cryo and Earth Storable Gas Systems (CESGS. Stage Preparation Facilities (SPB, L-110 & SSPF) • Compressed Gases Storage Building • Cryo Preparation Building Gas storage and service facility is meant for the boosting of gases viz., Helium, Nitrogen and Air up to 40 MPa and storing the gases in the high pressure gas cylinders. There are about 450 Cylinders (2 cu.m. /1 cu.m./0.5 cu.m.) in the launch pads. This facility consists of the following sub systems. • Gas Charging systems (Helium, Nitrogen & Air) • Gas Storage systemGas regulation and distribution system • Stage servicing equipment Nitrogen gas charging system: Nitrogen gas charging system will receive liquid nitrogen in to the Liquid nitrogen storage tank and directly pump the liquid through vaporizers to convert into gaseous nitrogen and charged in to high pressure storage cylinders. The following activities are to be carried out. • Running of LN2 pumps for gas boosting • Configuration of gas cylinders for gas boosting • Monitoring & surveillance of the gas boosting activity. • Charging of GN2 mobile gas modules to users Helium gas charging system: Helium gas charging system will receive liquid helium in to the Liquid helium storage tank and through vaporizers liquid helium is converted into gaseous helium. The gas is boosted to cylinders by using helium compressors. The following activities are to be carried out. • Running of Helium compressor for gas boosting • Configuration of gas cylinders for gas boosting • Monitoring & surveillance of the gas boosting activity. • Charging of GHe mobile gas modules to users (Refer work format for Group E (page No.66) for details of the works of individual facilities.)
AutoNDA by SimpleDocs

Related to Cryo and Earth Storable Gas Systems (CESGS

  • Energy Resource Interconnection Service (ER Interconnection Service).

  • Network Resource Interconnection Service (check if selected)

  • OVATIONS FOOD SERVICES, L.P. dba SPECTRA All food and beverage service must be discussed with and approved by Spectra, the OCFEC Master Concessionaire. FORM F-31 AGREEMENT NO. R-026-18 DATE May 16, 2018 REVIEWED APPROVED RENTAL AGREEMENT FAIRTIME INTERIM XX THIS AGREEMENT by and between the 32nd District Agricultural Association dba OC Fair & Event Center, hereinafter called the Association, and B & L Productions, Inc. hereinafter, called the Rentor

  • PROPANE GAS SYSTEM SERVICE AREA If the Property is located in a propane gas system service area owned by a distribution system retailer, Seller must give Buyer written notice as required by §141.010, Texas Utilities Code. An addendum containing the notice approved by TREC or required by the parties should be used.

  • Electric Storage Resources Developer interconnecting an electric storage resource shall establish an operating range in Appendix C of its LGIA that specifies a minimum state of charge and a maximum state of charge between which the electric storage resource will be required to provide primary frequency response consistent with the conditions set forth in Articles 9.5.5, 9.5.5.1, 9.5.5.2, and 9.5.5.3 of this Agreement. Appendix C shall specify whether the operating range is static or dynamic, and shall consider (1) the expected magnitude of frequency deviations in the interconnection; (2) the expected duration that system frequency will remain outside of the deadband parameter in the interconnection; (3) the expected incidence of frequency deviations outside of the deadband parameter in the interconnection; (4) the physical capabilities of the electric storage resource; (5) operational limitations of the electric storage resources due to manufacturer specification; and (6) any other relevant factors agreed to by the NYISO, Connecting Transmission Owner, and Developer. If the operating range is dynamic, then Appendix C must establish how frequently the operating range will be reevaluated and the factors that may be considered during its reevaluation. Developer’s electric storage resource is required to provide timely and sustained primary frequency response consistent with Article 9.5.5.2 of this Agreement when it is online and dispatched to inject electricity to the New York State Transmission System and/or receive electricity from the New York State Transmission System. This excludes circumstances when the electric storage resource is not dispatched to inject electricity to the New York State Transmission System and/or dispatched to receive electricity from the New York State Transmission System. If Developer’s electric storage resource is charging at the time of a frequency deviation outside of its deadband parameter, it is to increase (for over-frequency deviations) or decrease (for under-frequency deviations) the rate at which it is charging in accordance with its droop parameter. Developer’s electric storage resource is not required to change from charging to discharging, or vice versa, unless the response necessitated by the droop and deadband settings requires it to do so and it is technically capable of making such a transition.

  • Mobile Gas Service Corp 350 U.S. 332 (1956) and Federal Power Commission v. Sierra Pacific Power Co., 350 U.S. 348 (1956) , and clarified by Xxxxxx Xxxxxxx Capital Group, Inc. v.

  • Air Transport Services 1. For the purposes of this Article:

  • Electric Systems Are there any problems with electrical fuses, circuit breakers, outlets or wiring? Yes No. Unknown Comments:

  • SERVICE MONITORING, ANALYSES AND ORACLE SOFTWARE 11.1 We continuously monitor the Services to facilitate Oracle’s operation of the Services; to help resolve Your service requests; to detect and address threats to the functionality, security, integrity, and availability of the Services as well as any content, data, or applications in the Services; and to detect and address illegal acts or violations of the Acceptable Use Policy. Oracle monitoring tools do not collect or store any of Your Content residing in the Services, except as needed for such purposes. Oracle does not monitor, and does not address issues with, non-Oracle software provided by You or any of Your Users that is stored in, or run on or through, the Services. Information collected by Oracle monitoring tools (excluding Your Content) may also be used to assist in managing Oracle’s product and service portfolio, to help Oracle address deficiencies in its product and service offerings, and for license management purposes.

Time is Money Join Law Insider Premium to draft better contracts faster.