Description and Operation Sample Clauses

Description and Operation. The capacity of the solid-state rectifier section shall be sufficient to maintain the battery in a fully charged condition and continuously supply the required load through the inverter while floating the battery. The system offered shall not include any switching device or devices that shall interrupt the continuity of power in any way. The output voltage of the UPS shall be maintained within ± 3% over the nominal output voltage under any load conditions within UPS rating and ambient temperature range specified. The sine wave output shall have a maximum of 5% total harmonic distortion over the entire range of output voltage at any load or power factor. Automatic Frequency regulation shall maintain the output frequency to within ± 0.1 Hz for all combinations of temperature, input voltage variation and load variation. The output shall not follow the reference source beyond ± 0.3% Hz of nominal frequency. When input returns to normal, the UPS shall automatically synchronize to the line frequency. The components shall be selected to provide sufficient voltage capability and ample current-carrying capacity to furnish reasonable margin for handling over-currents and minor voltage variations. In no case shall components be operated at greater than 80% of the device's maximum steady state rating. The UPS shall be capable of withstanding, without failure, short circuit currents and surges of magnitude and duration in accordance with ANSI/IEEE Standard C62.41, categories A and B. The UPS shall be capable of providing 100% of the rated UPS output current continuously and shall be capable of providing 150% of rated output current for approximately 10 minutes. The system transient response shall be ±5% from nominal peak voltage f or 100 % load step. Voltage recovery shall be within 4 msec. to ±3% of nominal voltage. The battery system shall be of the lead acid maintenance-free sealed, non-gaseous type. The rectifier shall maintain a DC output voltage regulation of ±1% with a maximum of 2% RMS ripple. Rectifier shall be of the solid-state full wave SC bridge design to limit AC wave-shape distortion on the power system. As a minimum, over current protection (10KAIC circuit breakers or 100 KAIC C.
AutoNDA by SimpleDocs

Related to Description and Operation

  • Application and Operation Subject Matter No. Clause PART 1 - APPLICATION AND OPERATION Title 1.1 Arrangement 1.2 Objectives 1.3 Commencement date 1.4 Coverage 1.5 Exemptions from coverage 1.6 Relationship with other Industrial instruments 1.7 Definitions 1.8 Commitment of parties 1.9 Transitional arrangements 1.10 PART 2 - TRAINING CONDITIONS Training conditions 2.1 PART 3 - EMPLOYMENT CONDITIONS General 3.1 Part-time apprentices or trainees 3.2 School-based apprentices or trainees 3.3 Alternative employment arrangements 3.4 PART 4 - WAGES AND RELATED MATTERS General 4.1 Entry wage level 4.2 Wage progressions 4.3 Completion of apprenticeship or traineeship 4.4 Part-time apprentices or trainees 4.5 School-based apprentices or trainees 4.6 Areas of employment not covered by an Industrial instrument 4.7 Existing employees 4.8 Adult apprentices and trainees 4.9 Pre-employment, pre-trade, pre-apprenticeship, pre-vocational and other full-time institutional training 4.10 Apprentices and trainees with a disability 4.11 Payment for supervised training 4.12 Supply of tools 4.13 PART 5 -DISPUTE RESOLUTION AND INDUSTRIAL RELATIONS MATTERS Grievance and dispute settlement procedures 5.1 Industrial relations 5.2 SCHEDULES Generic Wage Progression Arrangements for Apprentices and Trainees Schedule Community Services and Health Industries Schedule

  • Use and Operation 3.1 Permitted Use ......................................................................................................

  • Maintenance and Operation Member-Generator agrees to maintain their system and facilities in accordance with applicable manufacturer's recommended maintenance schedule and standard prudent engineering practices. Member-Generator covenants and agrees to operate their system, facilities and equipment so as to minimize the likelihood for a malfunction or other disturbance, damaging or otherwise affecting or impairing Cooperative’s electrical system. Member-Generator shall comply with all applicable laws, regulations, zoning, building codes, safety rules and other environmental regulations or restrictions applicable to the design, installation, operation and maintenance of the Member-Generator's System.

  • Business and Operations Borrower will continue to engage in the businesses presently conducted by it as and to the extent the same are necessary for the ownership, maintenance, management and operation of the Property. Borrower will qualify to do business and will remain in good standing under the laws of each jurisdiction as and to the extent the same are required for the ownership, maintenance, management and operation of the Property.

  • Management and Operation 6.01 Management of Partnership Affairs 16 6.02 Duties and Obligations of General Partner 17 6.03 Release and Indemnification 17 6.04 Power of Attorney 18

  • Management and Operations Promotes the learning and growth of all students and the success of all staff by ensuring a safe, efficient, and effective learning environment, using resources to implement appropriate curriculum, staffing, and scheduling

  • Delegation and Operation OF TOP–LEVEL DOMAIN; REPRESENTATIONS AND WARRANTIES

  • Ratification and operation The provisions of this Agreement other than this Clause and Clauses 1, 2 and 3 shall not come into operation until the Xxxx referred to in Clause 3 has been passed by the Parliament of Western Australia and comes into operation as an Act.

  • Communications and Operations Management a. Network Penetration Testing - DST shall, on approximately an annual basis, contract with an independent third party to conduct a network penetration test on its network having access to or holding or containing Fund Data. DST shall have a process to review and evaluate high risk findings resulting from this testing.

  • Application and Operation of Agreement Table Of Contents

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!