Design Requirements The DG Facility shall be installed in compliance with Wisconsin Administrative Code Chapter PSC 119.
CONTRACT COMPLIANCE REQUIREMENT The HUB requirement on this Contract is 0%. The student engagement requirement of this Contract is 0 hours. The Career Education requirement for this Contract is 0 hours. Failure to achieve these requirements may result in the application of some or all of the sanctions set forth in Administrative Policy 3.10, which is hereby incorporated by reference.
FERPA Compliance In connection with all FERPA Records that Contractor may create, receive or maintain on behalf of University pursuant to the Underlying Agreement, Contractor is designated as a University Official with a legitimate educational interest in and with respect to such FERPA Records, only to the extent to which Contractor (a) is required to create, receive or maintain FERPA Records to carry out the Underlying Agreement, and (b) understands and agrees to all of the following terms and conditions without reservation:
ADA Compliance A. The Americans with Disabilities Act (42 U.S.C. § 12101, et seq.) and the regulations thereunder (28 C.F.R. § 35.130) (“ADA”) prohibit discrimination against persons with disabilities by the State, whether directly or through contractual arrangements, in the provision of any aid, benefit, or service. As a condition of receiving this Agreement, the Company certifies that services, programs, and activities provided under this Agreement are and will continue to be in compliance with the ADA. B. The Company further certifies that all facilities utilized by the Company in the performance of this Agreement comply with State accessibility laws.
FDA Compliance The Company: (A) is and at all times has been in material compliance with all statutes, rules or regulations of the FDA and other comparable governmental entities applicable to the ownership, testing, development, manufacture, packaging, processing, use, distribution, marketing, labeling, promotion, sale, offer for sale, storage, import, export or disposal of any product under development, manufactured or distributed by the Company (“Applicable Laws”); (B) has not received any FDA Form 483, notice of adverse finding, warning letter, untitled letter or other correspondence or notice from the FDA or any governmental entity alleging or asserting material noncompliance with any Applicable Laws or any licenses, certificates, approvals, clearances, exemptions, authorizations, permits and supplements or amendments thereto required by any such Applicable Laws (“Authorizations”); (C) possesses all material Authorizations and such Authorizations are valid and in full force and effect and the Company is not in material violation of any term of any such Authorizations; (D) has not received notice of any claim, action, suit, proceeding, hearing, enforcement, investigation, arbitration or other action from the FDA or any governmental entity or third party alleging that any product operation or activity is in material violation of any Applicable Laws or Authorizations and has no knowledge that the FDA or any governmental entity or third party is considering any such claim, litigation, arbitration, action, suit, investigation or proceeding; (E) has not received notice that the FDA or any governmental entity has taken, is taking or intends to take action to limit, suspend, modify or revoke any material Authorizations and has no knowledge that the FDA or any governmental entity is considering such action; and (F) has filed, obtained, maintained or submitted all material reports, documents, forms, notices, applications, records, claims, submissions and supplements or amendments as required by any Applicable Laws or Authorizations and that all such reports, documents, forms, notices, applications, records, claims, submissions and supplements or amendments were materially complete and correct on the date filed (or were corrected or supplemented by a subsequent submission).
CEQA Compliance The District has complied with all assessment requirements imposed upon it by the California Environmental Quality Act (Public Resource Code Section 21000 et seq. (“CEQA”) in connection with the Project, and no further environmental review of the Project is necessary pursuant to CEQA before the construction of the Project may commence.
Construction Requirements (a) All Life and Safety and applicable Building Codes will be strictly enforced (i.e., tempered glass, fire dampers, exit signs, smoke detectors, alarms, etc.). Prior coordination with the Building Manager is required. (b) Electric panel schedules must be brought up to date identifying all new circuits added. (c) All electrical outlets and lighting circuits are to be properly identified. Outlets will be labeled on back side of each cover plate. (d) All electrical and phone closets being used must have panels replaced and doors shut at the end of each day’s work. Any electrical closet that is opened with the panel exposed must have a work person present. (e) All electricians, telephone personnel, etc. will, upon completion of their respective projects, pick up and discard their trash leaving the telephone and electrical rooms clean. If this is not complied with, a clean-up will be conducted by the building janitors and the general contractor will be back-charged for this service. (f) Welding or burning with an open flame will not be done without prior approval of the Building Manager. Fire extinguishers must be on hand at all times. (g) All “anchoring” of walls or supports to the concrete are not to be done during normal working hours (7:30 AM—6:00 PM, Monday through Friday). This work must be scheduled before or after these hours during the week or on the weekend. (h) All core drilling is not to be done during normal working hours (7:30 AM—6:00 PM, Monday through Friday). This work must be scheduled before or after these hours during the week or on the weekend. (i) All HVAC work must be inspected by the Building Engineer. The following procedures will be followed by the general contractor: i) A preliminary inspection of the HVAC work in progress will be scheduled through the Building Office prior to the reinstallation of the ceiling grid. ii) A second inspection of the HVAC operation will also be scheduled through the Building Office and will take place with the attendance of the HVAC contractor’s Air Balance Engineer. This inspection will take place when the suite in question is ready to be air-balanced. [***] = CONFIDENTIAL INFORMATION HAS BEEN OMITTED AND FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION. CONFIDENTIAL TREATMENT HAS BEEN REQUESTED WITH RESPECT TO THIS OMITTED INFORMATION. iii) The Building Engineer will inspect the construction on a periodic basis as well. (j) All existing thermostats, ceiling tiles, lighting fixtures and air conditioning grilles shall be saved and turned over to the Building Engineer.
Contract Compliance All individual employee contracts entered into and/or in force during the duration of this Agreement shall be subject to and consistent with Washington State law and the terms and conditions of this Agreement. Any individual employee contract executed shall expressly provide that it is subject to the terms of this and subsequent Agreements between the District and the Association. If any individual employee contract contains any language inconsistent with this Agreement, this Agreement, during its duration, shall be controlling.
HIPAA Compliance If this Contract involves services, activities or products subject to the Health Insurance Portability and Accountability Act of 1996 (HIPAA), the Contractor covenants that it will appropriately safeguard Protected Health Information (defined in 45 CFR 160.103), and agrees that it is subject to, and shall comply with, the provisions of 45 CFR 164 Subpart E regarding use and disclosure of Protected Health Information.
W-9 Requirement Alongside a signed copy of this Agreement, Grantee will provide Florida Housing with a properly completed Internal Revenue Service (“IRS”) Form W-9. The purpose of the W-9 form is to document the SS# or FEIN# per the IRS. Note: W-9s submitted for any other entity name other than the Grantee’s will not be accepted.