Detailed System Description Sample Clauses

Detailed System Description. Since the release of Deliverable 2.1, the designed architecture of the Type 1 install has only seen a minor amendment; below will describe the use of a gateway controller, instead of a VCharge (OVO) Dynamo unit, which in turn will communicate with the Sunamp PCM heat battery via the Sunamp Qontroller unit. The install will still principally be based on the use of a suitably scaled Sunamp UniQ PCM heat battery with the capacity to be fed heat through the use of the properties existing heat source, or the battery’s internally built-in heating elements. This configuration, or an amended version of, will be installed in 15 properties. Figure 6 below illustrates the configuration and components within the type 1 heating installations; those within the white background being those installed under SMILE, those with the grey background highlight pre-existing equipment.
AutoNDA by SimpleDocs
Detailed System Description. The designed architecture for type 2 has similarities with type 1, through the use of a Sunamp PCM heat battery as the main form of energy storage, however using an Air to Water Heat Pump to be the principle form of heat generation, in place of using the pre-existing heat source. Furthermore, the design has been altered since the release of Deliverable 2.1; the design now will install PCM heat batteries with internal heat elements, which allow the battery to charge from an electrical source, as well as the pumped hot water source, even though the PCM heat battery also has internal heating elements. As such, the previously described use of VCharge (OVO) Dynamos to control the installed equipment will be replaced by the use of a gateway controllers. This configuration, or an amended version of, will be installed in 15 properties, and outlined in Figure 8 below.
Detailed System Description. The configuration for type 3 will pair an Air to Water Heat Pump with hot water storage; similar to type 2 but testing the effectiveness of hot water storage in compared to Sunamp PCM heat batteries. This configuration, or an amended version of, will be installed in 10 properties and outlined below in Figure 11.
Detailed System Description. The type 4 installation (Figure 13) will further build upon the type 3 installation, with the use and benefits of electrical storage, air to water heat pumps and hot water storage. With the exception of the stationary electrical battery, the type 4 installation is the same as that of type 3. The battery will further allow for quick response to curtailment signals, while also supplementing the energy requirements of the ASHP with power stored from off-peak periods.

Related to Detailed System Description

  • System Description The DLCS is a network consisting of devices which are remotely controlled over RF transmission equipment by the PowerCAMPTM Software or equivalent. CL&P shall have access to the PowerCAMP™ LMS (as defined below) via the web interface. The PowerCAMPTM LMS shall include the software and hardware necessary to manage the Control Devices installed at the End-use Equipment at Participating Facilities. The PowerCAMPTM LMS includes AER’s PowerCAMPTM Server and PowerCAMPTM Suite, networking equipment, and third party software. PowerCAMPTM LMS Hardware

  • Service Description The Parties will provide Common Channel Signaling (CCS) to one another via Signaling System 7 (SS7) network Interconnection, in accordance with prevailing industry standards. Use of a third party provider of SS7 trunks is permitted.

  • ITEM DESCRIPTION Equipment (include VIN, make, model, year, serial no., accessories, or other identifying features): 12. NO. OF OPERATORS PER SHIFT 13. HRLY/ DAILY/ MILEAGE SHIFT BASIS 14. SPECIAL 15. GUARANTEE (8 HOURS) Rate Unit Portable Toilet Rental – Serviced(Includes first day delivery/last day pickup and daily rental rate per unit) 1 $75 Daily Ea. Portable Toilet Rental – Unserviced(Rental only, no daily service call) 1 $45 Daily Ea. Accessible Portable Toilet Rental – Serviced(Includes first day delivery/last day pickup and daily rental rate per unit) 1 $95 Daily Ea. Accessible Portable Toilet Rental – Unserviced(Rental only, no daily service call) 1 $65 Daily Ea.

  • Project Description In two or three brief sentences, provide a concise description of your exhibition. Include the subject matter, type of objects to be included (paintings, sculpture, manuscripts, etc.), those responsible for organizing the exhibition, and catalogue author(s).

  • Service Descriptions Available services for Transitional and Enhanced Supervision Services a. One (1) one-to-one meeting with the Contractor per week for case management services.

  • Task Description This task includes activities associated with permit-required monitoring conducted in accordance with the conditions specified by state or federal regulatory agencies. All monitoring tasks must be located within or adjacent to the Project area and follow the Department’s Regional Coastal Monitoring Program and FWC's marine turtle and shorebird monitoring programs. Guidance for monitoring of nearshore resources is available in the Department's Standard Operation Procedures For Nearshore Hardbottom Monitoring Of Beach Nourishment Projects. The Local Sponsor must submit work products directly to the appropriate state or federal regulatory agencies in accordance with permit conditions to be eligible for reimbursement under this task, unless otherwise directed.

  • Contract Description The Description and Location of the Contract and related project(s) are as follows.

  • Work Description T-804 Opening Roads - Removal of closure devices, cleaning ditches, removing berms, and blading the traveled-way T-811 Closing Roads - Entrance treatment for 150' cross-rip; debris block (slash, earth, berm, rocks, etc.) + seed + water bar T-811 Closing Roads - Water bar frequency per BMPs for remainder of road T-811 Closing Roads - Engineering Rep. or Construction Inspector must be notified prior to performing closeout NFSR Road No. Lane Width & Maintenance Level Mile Marker Begin End 76L Single Lane / Level 2 76 0.00 Ending 0.48

  • Site Description 2.5.1 If reasonably requested by the A/E as necessary for the Project, the Owner shall furnish a legal description and a certified land survey of the Site, giving, as applicable, grades and lines of streets, alleys, pavements and adjoining property; rights-of-way, restrictions, easements, encroachments, zoning, deed restrictions, boundaries and contours of the Site; locations, dimensions, and complete data pertaining to existing buildings, other improvements, and trees; and full information concerning available service and utility lines, both public and private, above and below grade, including inverts and depths.

  • Program Description The employer agrees to provide a vision benefit to eligible employees and dependents. The vision benefit provided by the State shall have an employee co-payment of $10 for the comprehensive annual eye examination and $25 for materials.