Common use of DOORS AND WINDOWS Clause in Contracts

DOORS AND WINDOWS. The Contractor shall furnish all materials, labor, services, tools and equipment required for the supply and installation of hollow metal doors, rolling steel doors, windows, glass and glazing, and hardware for the project. Hollow metal doors, frames and components shall be manufactured from hot-dipped galvanized cold rolled steel. Doors shall have insulated cores. The doors and frames shall be shop primed and field finish painted. Doors shall have vision lites, louvers, dampers, etc. as required by their location. The doors and frames shall be furnished and installed per Steel Door Institute (SDI) requirements. Fire rated doors shall comply with NFPA Standard No. 80 and be tested and labeled per UL requirements. All hinged exterior doors shall have automatic door closures. Rolling steel doors and frames shall be manufactured from hot-dipped galvanized cold rolled steel and have insulated interlocking slats. All rolling steel doors shall be motor operated with chain backup. Doors shall be factory primed and field finish painted. Windows shall be manufactured of extruded aluminum frames and ventilator sections. Windows shall be either horizontal sliding type or fixed type depending on location. In general, exterior windows shall be sliding type with screens and storm sash, and interior windows shall be fixed type. Frames shall meet standards of Architectural Aluminum Manufacturer's Association. Hardware shall provide locking capability for all sliding windows. Finish shall be selected by the Owner from the Manufacturer's standard finishes. The main entrance to main building shall be a double doored vestibule with glass doors and walls. Glass and glazing for windows and doors shall comply with applicable ASTM standards, Federal Specifications and Flat Glass Marketing Association. Glass for fire rated applications shall comply with NFPA No. 80 standard for Fire Doors and Windows. Glass for exterior applications shall be tinted insulating glass. Hardware for doors shall comply with applicable sections of Americans with Disabilities Act (ADA), ANSI standards, Builders Hardware Manufacturers Association (BHMA) and SDI. Hardware for fire doors shall comply with NFPA 80 and UL requirements. All hardware shall be installed per manufacturer's recommendations. All locksets shall be master keyed with no more than two master key groups.

Appears in 2 contracts

Samples: Engineering, Procurement and Construction Agreement (Tenaska Georgia Partners Lp), Engineering, Procurement and Construction Agreement (Tenaska Georgia Partners Lp)

AutoNDA by SimpleDocs

DOORS AND WINDOWS. The Contractor Doors and frames at the main entrance shall furnish all materialsbe aluminum entrances or storefront material with thermal break equal to systems designed and engineered by Kawneer Co., laborInc. or Tubelite Division, servicesIndal, tools Inc. Finish is to be dark bronze (M10-C22-A44). All exterior pedestrian door frames and equipment required those door frames of adjacent air lock vestibules shall be constructed to accept electric strike hardware (for the supply and installation of hollow metal doors, rolling steel doors, windows, glass and glazinga biometric access system), and hardware prepped for the projectintrusion alarm system contacts. Hollow metal doors, frames and components shall be manufactured from hot-dipped galvanized cold rolled steel. Doors shall have insulated cores. The Loading dock doors and frames shall be shop primed prepped for intrusion alarm system contacts. All exterior doors and field finish paintedframes, except at main entrance, shall be custom hollow metal construction provided with heavy duty commercial grade hardware. Doors The main entrance shall be 2 pairs of 36" doors arranged to create an air lock vestibule. Door face sheets shall be commercial quality, roller leveled, cold roll, 16 gauge steel with 18 gauge stiffeners at 6" on center. Provide polystyrene or urethane insulation core filler. All exposed steel surfaces shall be cleaned, bonded and coated with a baked on zinc chromate based prime paint. Frames shall be prefabricated combination buck, frame, and trim type. Mitered joints shall have vision lites, louvers, dampers, etclocking tabs at frame rabbets and backboards. as required by their location. The doors and All interior door frames shall be furnished with rubber bumpers. Provide 14 gauge door frames for exterior openings and installed per Steel Door Institute (SDI) requirements16 gauge door frames for interior openings. Fire rated Reinforce, drill, and tap doors and frames for fully-templated mortised and concealed hardware. Delivery door opening is to be not less than 72" wide. The main entry and airlock vestibule door opening shall comply with NFPA Standard No. 80 allow for a 72" wide clear opening, and all other doors are to be tested and labeled per UL requirements36" wide. All hinged exterior doors shall be weather-stripped, have automatic a commercial quality aluminum threshold of low profile (beveled) design not to exceed 2” high. Bevel angle shall not exceed 300. Main entry door closures. Rolling steel doors and frames point shall be manufactured protected from hot-dipped galvanized cold rolled steel rainwater and have insulated interlocking slatssnow by a canopy. All rolling steel Other exterior doors shall be motor operated protected from water by metal flashing over the door heads. Provide an eye level peephole in the delivery door. Provide a xxxx push at the delivery door with chain backup. Doors shall be factory primed and field finish painted. Windows shall be manufactured of extruded aluminum frames and ventilator sections. Windows shall be either horizontal sliding type or fixed type depending on location. In general, exterior windows shall be sliding type with screens and storm sash, and interior windows shall be fixed type. Frames shall meet standards of Architectural Aluminum Manufacturer's Association. Hardware shall provide locking capability for all sliding windows. Finish shall be selected by a buzzer at the Owner from the Manufacturer's standard finishes. The main entrance to main building shall be a double doored vestibule with glass doors and walls. Glass and glazing for windows and doors shall comply with applicable ASTM standards, Federal Specifications and Flat Glass Marketing Association. Glass for fire rated applications shall comply with NFPA No. 80 standard for Fire Doors and Windows. Glass for exterior applications shall be tinted insulating glass. Hardware for doors shall comply with applicable sections of Americans with Disabilities Act (ADA), ANSI standards, Builders Hardware Manufacturers Association (BHMA) and SDI. Hardware for fire doors shall comply with NFPA 80 and UL requirements. All hardware shall be installed per manufacturer's recommendations. All locksets shall be master keyed with no more than two master key groupsreception counter.

Appears in 2 contracts

Samples: Lease Agreement, Lease Agreement

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!