Ownership and Location of Metering Equipment The Metering Equipment to be constructed, the capability of the Metering Equipment to be constructed, and the ownership thereof, are identified on the attached Schedule C to this ISA.
Scaling Location Forest Service shall provide Scaling services at the Scaling site(s) shown in A10. The Scaling site(s) shown in A10 normally will be a non-exclusive site where more than one National Forest timber sale Purchaser may be served. Purchaser may request, in writing, an alternate Scal- ing site, such as at a private mill yard, private truck ramp, or a privately operated log transfer facility. Contracting Of- ficer may approve an alternate Scaling site, when Con- tracting Officer determines that Scaling conditions at an alternate site are acceptable. Such conditions shall in- clude at a minimum:
Data Location 1.1. The CONTRACTOR shall not store or transfer non-public COUNTY data outside of the United States. This includes backup data and Disaster Recovery locations. The CONTRACTOR will permit its personnel and contractors to access COUNTY data remotely only as required to provide technical support. (Remote access to data from outside the continental United States is prohibited unless approved in advance and in writing by the County.)
Scaling Locations, Rules, and Organizations All logs from timber sold under the terms and conditions of this contract shall be: (1) scaled at a location approved in writing by STATE; (2) scaled by a third-party scaling organization with a current agreement with STATE; and (3) scaled using the Official Log Scaling and Grading Rules (as adopted by the Northwest Log Rules Advisory Group) and STATE special service scaling instructions in effect at the time the logs are scaled. Utilization scale shall be handled in accordance with the section titled, “Utilization Scale.” PURCHASER shall enter into a written agreement with a third-party scaling organization for the scaling of logs removed from the timber sale area. PURCHASER shall furnish STATE with a copy of the scaling agreement upon request. If logs are delivered when a TPSO scaler is not present, PURCHASER must provide STATE with a method to assure protection and accountability. PURCHASER shall provide STATE with remote check scaling opportunities for logs scaled under this contract. The last two loads at each delivery point shall be continuously available for checking. They shall remain available for a minimum of 48 hours unless replaced by other STATE loads. They shall be available as originally presented for scaling; i.e., if truck scaled, they shall be presented in bunks. In the event scaling is suspended for any reason, hauling operations shall be immediately suspended until approved alternate scaling services are provided, or service by the scaling organization is resumed.
UNDERGROUND LOCATIONS Prior to the Company commencing any work the Customer must advise the Company of the precise location of all underground services on the site and clearly xxxx the location. The underground mains and services the Customer must identify include, but are not limited to, telephone cables, fibre optic cables, electrical services, gas services, sewer services, pumping services, sewer connections, sewer sludge mains, water mains, irrigations pipes, oil pumping mains and any other services that may be on site. Whilst the Company will take all care to avoid damage to any underground services the Customer agrees to indemnify the Company in respect of all any liability claims, loss, damage, cost and fines as a result of damage to services not precisely located and notified pursuant to this clause.
PREVAILING WAGE RATES - PUBLIC WORKS AND BUILDING SERVICES CONTRACTS If any portion of work being Bid is subject to the prevailing wage rate provisions of the Labor Law, the following shall apply:
Use of Basement and Service Areas The basement(s) and service areas, if any, as located within the (project name), shall be earmarked for purposes such as parking spaces and services including but not limited to electric sub-station, transformer, DG set rooms, underground water tanks, pump rooms, maintenance and service rooms, fire fighting pumps and equipment's etc. and other permitted uses as per sanctioned plans. The Allottee shall not be permitted to use the services areas and the basements in any manner whatsoever, other than those earmarked as parking spaces, and the same shall be reserved for use by the association of allottees formed by the Allottees for rendering maintenance services.
Co-Location 1. Each Party shall ensure that major suppliers in its territory provide to suppliers of public telecommunications services of the other Party physical co-location of equipment necessary for interconnection or access to unbundled network elements on a timely basis and on terms, conditions and at cost-oriented rates that are reasonable and non-discriminatory.
Project Location [Insert the location of the Project, if applicable]
Unbundled Loop Concentration (ULC) System 2.5.1 BellSouth will provide to <<customer_name>> Unbundled Loop Concentration (ULC). Loop concentration systems in the central office concentrate the signals transmitted over local loops onto a digital loop carrier system. The concentration device is placed inside a BellSouth central office. BellSouth will offer ULC with a TR008 interface or a TR303 interface.