FAILURE TO SUPPLY; CAPACITY ALLOCATION Sample Clauses

FAILURE TO SUPPLY; CAPACITY ALLOCATION. (a) In the event that Alliance, upon receiving a forecast under Section 2.2 or a firm order under Section 2.3, is, or anticipates that it will be, unable to meet such forecast or firm order, either in whole or in part, and whether due to circumstances arising under Section 11.3 or otherwise, Alliance shall give written notice of such inability to HMRI within ten days of receipt of such forecast or firm order. If such inability is partial, Alliance shall deliver against firm orders such quantities of Material as are available. (b) Alliance and HMRI shall meet within 15 days of such written notice to consider and, if appropriate, pursue alternative arrangements for meeting HMRI's requirements for Material. Such arrangements may include transferring equipment and/or technology necessary for the production of Material to an alternative site or to a Third Party, manufacturing Material at HMRI's own facilities, or, if HMRI is already manufacturing quantities of Material, increasing HMRI's production of Material, PROVIDED that any such alternative pursued shall be subject to all required regulatory approvals. Any alternative arrangements entered into pursuant to this Section 2.7 shall act in no way as a waiver of any other rights or remedies which HMRI may have under this Agreement or otherwise. (c) In the event that Alliance's inability to meet firm orders or forecasts is due to a shortage of production capacity at Alliance's facilities, in addition to the requirements on Section 2.7(a) and Section 2.7(b) above, Alliance shall promptly notify HMRI of such shortage of production capacity, and, if possible, the date such shortage of production capacity is expected to end. In such event, Alliance shall allocate its available production capacity to the production of Material in such proportion as the production capacity actually utilized to meet orders for Material over the previous 12 month period bears to Alliance's total production capacity over that same period. (d) Alliance shall notify HMRI as soon as possible of the date upon which such shortage of production capacity will cease. Within 30 days of such notification, HMRI shall resume obtaining its requirements for Material in such proportions as HMRI ordered from Alliance prior to the shortage of production to the extent such resumption is consistent with the contractual arrangements entered into as provided in Section 2.7(b).
AutoNDA by SimpleDocs
FAILURE TO SUPPLY; CAPACITY ALLOCATION 

Related to FAILURE TO SUPPLY; CAPACITY ALLOCATION

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.1.3.1 Definition 4.1.3.2 Notwithstanding BellSouth’s general duty to unbundle local circuit switching, BellSouth shall not be required to unbundle local circuit switching for <<customer_name>> when <<customer_name>> serves end-users with four (4) or more voice-grade (DS-0) equivalents or lines in locations served by BellSouth’s local circuit switches, which are in the following MSAs: Atlanta, GA; Miami, FL; Orlando, FL; Ft. Lauderdale, FL; Charlotte-Gastonia-Rock Hill, NC; Greensboro-Winston Salem-High Point, NC; Nashville, TN; and New Orleans, LA, and BellSouth has provided non-discriminatory cost based access to the Enhanced Extended Link (EEL) throughout Density Zone 1 as determined by NECA Tariff No. 4 as in effect on January 1, 1999. 4.1.3.3 In the event that <<customer_name>> orders local circuit switching for a single end user account name at a single physical end user location with four (4) or more 2-wire voice-grade loops from a BellSouth central office in an MSA listed above, BellSouth shall charge <<customer_name>> the market based rate in Exhibit C for use of the local circuit switching functionality for the affected facilities. 4.1.3.4 A featureless port is one that has a line port, switching facilities, and an interoffice port. A featured port is a port that includes all features then capable or a number of then capable features specifically requested by <<customer_name>>. Any features that are not currently then capable but are technically feasible through the switch can be requested through the NBR/BFR process. 4.1.3.5 BellSouth will provide to <<customer_name>> customized routing of calls: (i) to a requested directory assistance services platform; (ii) to an operator services platform pursuant to Section 10 of Attachment 2; (iii) for <<customer_name>>’s PIC’ed toll traffic in a two (2) PIC environment to an alternative OS/DA platform designated by <<customer_name>>. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers. 4.1.3.6 Remote Switching Module functionality is included in Switching Capability. The switching capabilities used will be based on the line side features they support. 4.1.3.7 Switching Capability will also be capable of routing local, intraLATA, interLATA, and calls to international customer’s preferred carrier; call features (e.g. call forwarding) and Centrex capabilities. 4.1.3.8 Where required to do so in order to comply with an effective Commission order, BellSouth will provide to <<customer_name>> purchasing local BellSouth switching and reselling BellSouth local exchange service under Attachment 1, selective routing of calls to a requested directory assistance services platform or operator services platform. <<customer_name>> customers may use the same dialing arrangements as BellSouth customers, but obtain a <<customer_name>> branded service.

  • Switching and Tagging Rules Each Party shall provide the other Parties a copy of its switching and tagging rules that are applicable to the other Parties’ activities. Such switching and tagging rules shall be developed on a non-discriminatory basis. The Parties shall comply with applicable switching and tagging rules, as amended from time to time, in obtaining clearances for work or for switching operations on equipment.

  • Ameliorative Allocations Any special allocations of income or gain pursuant to Sections 5.05(b) or 5.05(c) hereof shall be taken into account in computing subsequent allocations pursuant to Section 5.04 and this Section 5.05(g), so that the net amount of any items so allocated and all other items allocated to each Partner shall, to the extent possible, be equal to the net amount that would have been allocated to each Partner if such allocations pursuant to Sections 5.05(b) or 5.05(c) had not occurred.

  • Risk Allocation The Product is Regulatorily Continuing.

  • Interconnection Customer Compensation for Actions During Emergency Condition The CAISO shall compensate the Interconnection Customer in accordance with the CAISO Tariff for its provision of real and reactive power and other Emergency Condition services that the Interconnection Customer provides to support the CAISO Controlled Grid during an Emergency Condition in accordance with Article 11.6.

  • Section 704(c) Allocations Notwithstanding Section 6.5.A hereof, Tax Items with respect to Property that is contributed to the Partnership with an initial Gross Asset Value that varies from its basis in the hands of the contributing Partner immediately preceding the date of contribution shall be allocated among the Holders for income tax purposes pursuant to Regulations promulgated under Code Section 704(c) so as to take into account such variation. With respect to Partnership Property that is contributed to the Partnership in connection with the General Partner’s initial public offering, such variation between basis and initial Gross Asset Value shall be taken into account under the “traditional method” as described in Regulations Section 1.704-3(b). With respect to other Properties, the Partnership shall account for such variation under any method approved under Code Section 704(c) and the applicable Regulations as chosen by the General Partner. In the event that the Gross Asset Value of any Partnership asset is adjusted pursuant to subsection (b) of the definition of “Gross Asset Value” (provided in Article 1 hereof), subsequent allocations of Tax Items with respect to such asset shall take account of the variation, if any, between the adjusted basis of such asset and its Gross Asset Value in the same manner as under Code Section 704(c) and the applicable Regulations and using the method chosen by the General Partner; provided, however, that the “traditional method” as described in Regulations Section 1.704-3(b) shall be used with respect to Partnership Property that is contributed to the Partnership in connection with the General Partner’s initial public offering. Allocations pursuant to this Section 6.5.B are solely for purposes of Federal, state and local income taxes and shall not affect, or in any way be taken into account in computing, any Partner’s Capital Account or share of Net Income, Net Loss, or any other items or distributions pursuant to any provision of this Agreement.

  • Timing and Amount of Allocations of Net Income and Net Loss Net Income and Net Loss of the Partnership shall be determined and allocated with respect to each Partnership Year of the Partnership as of the end of each such year. Subject to the other provisions of this Article 6, an allocation to a Partner of a share of Net Income or Net Loss shall be treated as an allocation of the same share of each item of income, gain, loss or deduction that is taken into account in computing Net Income or Net Loss.

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Corrective Allocations In the event of any allocation of Additional Book Basis Derivative Items or any Book-Down Event or any recognition of a Net Termination Loss, the following rules shall apply: (A) In the case of any allocation of Additional Book Basis Derivative Items (other than an allocation of Unrealized Gain or Unrealized Loss under Section 5.5(d) hereof), the General Partner shall allocate additional items of gross income and gain away from the holders of Incentive Distribution Rights to the Unitholders and the General Partner, or additional items of deduction and loss away from the Unitholders and the General Partner to the holders of Incentive Distribution Rights, to the extent that the Additional Book Basis Derivative Items allocated to the Unitholders or the General Partner exceed their Share of Additional Book Basis Derivative Items. For this purpose, the Unitholders and the General Partner shall be treated as being allocated Additional Book Basis Derivative Items to the extent that such Additional Book Basis Derivative Items have reduced the amount of income that would otherwise have been allocated to the Unitholders or the General Partner under the Partnership Agreement (e.g., Additional Book Basis Derivative Items taken into account in computing cost of goods sold would reduce the amount of book income otherwise available for allocation among the Partners). Any allocation made pursuant to this Section 6.1(d)(xii)(A) shall be made after all of the other Agreed Allocations have been made as if this Section 6.1(d)(xii) were not in this Agreement and, to the extent necessary, shall require the reallocation of items that have been allocated pursuant to such other Agreed Allocations. (B) In the case of any negative adjustments to the Capital Accounts of the Partners resulting from a Book-Down Event or from the recognition of a Net Termination Loss, such negative adjustment (1) shall first be allocated, to the extent of the Aggregate Remaining Net Positive Adjustments, in such a manner, as determined by the General Partner, that to the extent possible the aggregate Capital Accounts of the Partners will equal the amount that would have been the Capital Account balance of the Partners if no prior Book-Up Events had occurred, and (2) any negative adjustment in excess of the Aggregate Remaining Net Positive Adjustments shall be allocated pursuant to Section 6.1(c) hereof. (C) In making the allocations required under this Section 6.1(d)(xii), the General Partner may apply whatever conventions or other methodology it determines will satisfy the purpose of this Section 6.1(d)(xii).

  • Under-Frequency and Over Frequency Conditions The New York State Transmission System is designed to automatically activate a load- shed program as required by the NPCC in the event of an under-frequency system disturbance. Developer shall implement under-frequency and over-frequency relay set points for the Large Generating Facility as required by the NPCC to ensure “ride through” capability of the New York State Transmission System. Large Generating Facility response to frequency deviations of predetermined magnitudes, both under-frequency and over-frequency deviations, shall be studied and coordinated with the NYISO and Connecting Transmission Owner in accordance with Good Utility Practice. The term “ride through” as used herein shall mean the ability of a Generating Facility to stay connected to and synchronized with the New York State Transmission System during system disturbances within a range of under-frequency and over-frequency conditions, in accordance with Good Utility Practice and with NPCC Regional Reliability Reference Directory # 12, or its successor.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!