Contract Type Full time equivalency (FTE); and,
NETWORK INTERCONNECTION METHODS 3.1 The Interconnection provided herein may not be used solely for the purpose of originating a Party’s own interexchange traffic.
Points of Interconnection and Trunk Types 2.1 Point(s) of Interconnection. 2.1.1 Each Party, at its own expense, shall provide transport facilities to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA selected by PNG.
Trunk Types 2.2.1 In interconnecting their networks pursuant to this Attachment, the Parties will use, as appropriate, the following separate and distinct trunk groups: 2.2.1.1 Interconnection Trunks for the transmission and routing of Reciprocal Compensation Traffic, translated LEC IntraLATA toll free service access code (e.g., 800/888/877) traffic, and IntraLATA Toll Traffic, between their respective Telephone Exchange Service Customers, Tandem Transit Traffic, and, Measured Internet Traffic, all in accordance with Sections 5 through 8 of this Attachment; 2.2.1.2 Access Toll Connecting Trunks for the transmission and routing of Exchange Access traffic, including translated InterLATA toll free service access code (e.g., 800/888/877) traffic, between Ymax Telephone Exchange Service Customers and purchasers of Switched Exchange Access Service via a Verizon access Tandem in accordance with Sections 9 through 11 of this Attachment; and 2.2.1.3 Miscellaneous Trunk Groups as mutually agreed to by the Parties, including, but not limited to: (a) choke trunks for traffic congestion and testing; and, (b) untranslated IntraLATA/InterLATA toll free service access code (e.g. 800/888/877) traffic. 2.2.2 Other types of trunk groups may be used by the Parties as provided in other Attachments to this Agreement (e.g., 911/E911 Trunks) or in other separate agreements between the Parties (e.g., directory assistance trunks, operator services trunks, BLV/BLVI trunks or trunks for 500/555 traffic). 2.2.3 In accordance with the terms of this Agreement, the Parties will deploy One-Way Interconnection Trunks (trunks with traffic going in one direction, including one-way trunks and uni-directional two-way trunks) and/or Two-Way Interconnection Trunks (trunks with traffic going in both directions). 2.2.4 Ymax shall establish, at the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA, separate Interconnection Trunk group(s) between such POI(s) and each Verizon Tandem in a LATA with a subtending End Office(s) to which Ymax originates calls for Verizon to terminate. 2.2.5 In the event the volume of traffic between a Verizon End Office and a technically feasible Point of Interconnection on Verizon’s network in a LATA, which is carried by a Final Tandem Interconnection Trunk group, exceeds (a) the Centium Call Seconds (Hundred Call Seconds) busy hour equivalent of one (1) DS1 at any time; (b) 200,000 minutes of use for a single month; and/or; (c) 600 busy hour Centium Call Seconds (BHCCS) of use for a single month: (i) if One-Way Interconnection Trunks are used, the originating Party shall promptly establish new or augment existing End Office One-Way Interconnection Trunk groups between the Verizon End Office and the technically feasible Point of Interconnection on Verizon’s network; or,
Switching System Hierarchy and Trunking Requirements For purposes of routing ECI traffic to Verizon, the subtending arrangements between Verizon Tandem Switches and Verizon End Office Switches shall be the same as the Tandem/End Office subtending arrangements Verizon maintains for the routing of its own or other carriers’ traffic (i.e., traffic will be routed to the appropriate Verizon Tandem subtended by the terminating End Office serving the Verizon Customer). For purposes of routing Verizon traffic to ECI, the subtending arrangements between ECI Tandem Switches and ECI End Office Switches shall be the same as the Tandem/End Office subtending arrangements that ECI maintains for the routing of its own or other carriers’ traffic.
Forecasting Requirements 19.5.1 The Parties shall exchange technical descriptions and forecasts of their Interconnection and traffic requirements in sufficient detail necessary to establish the Interconnections necessary for traffic completion to and from all Customers in their respective designated service areas.
Shift Rotation Routine shift rotation is not an approach to staffing endorsed by the Employer. Except for emergency situations where it may be necessary to provide safe patient care, shift rotation will not be utilized without mutual consent. If such an occasion should ever occur, volunteers will be sought first. If no one volunteers, the Employer will rotate shifts on an inverse seniority basis until the staff vacancies are filled.
Hot Weather Guidelines For the purposes of site based discussions regarding the need to plan and perform work during expected periods of hot weather, the following issues shall be considered in conjunction with proper consideration of Occupational Health and Safety issues.
Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.
Particular Methods of Procurement of Goods Works and Services (other than Consultants’ Services)