Grading The coarse aggregate as delivered to the mixer, shall be well graded as per IS specifications. Maximum size of aggregate used for the work shall be 20mm or 40mm or as specified in items in the bill of quantities and it shall confirm to IS: 383-1970, clause 4.2 (Table-2) However, the exact gradation required to produce a dense concrete of specified strength and desired workability shall be decided as per laboratory test by the Engineer. Coarse aggregate for use in concrete shall be well graded and shall conform to IS: 383-1970 requirements (as per Table-II) given below: 63mm 100 - - - 40mm 00-000 000 - - 20mm 00-00 00-000 100 - 16mm - - 00-000 000 12.5 - - - 90-100 10.00 00-00 00-00 00-00 00-00 4.75mm 0-5 0-10 0-10 0-10
Size The nominal maximum size of aggregate shall be as large as possible within the limits specified but in no case greater than one-fourth of the minimum thickness of the member, provided at the concrete can be placed without difficulty so as to surround all reinforcement thoroughly and fill the corners of the form work. For most works, 20mm aggregate shall be used and where there is no restriction to the flow of concrete into sections, 40mm size (MSA) shall be used. For any heavily reinforced concrete members, the nominal maximum size of aggregate shall usually be restricted to 5mm less than the minimum cover to the reinforcement or 5mm less than the minimum clear distance between the main bars. Coarse aggregate shall of all aggregate particles of size greater than 4.75mm. The aggregate shall conform to IS: 383- 1970 clause 3.1,3.2 and 3.2.1 (Table-I) The nominal maximum size of coarse aggregate to be used shall be as per drawing/as determined by Engineer-in-charge.
Upgrading You may request an Upgrade. For purposes of an Upgrade request, each individual who constitutes the Depositor under the agreement for Retail Direct Services is considered a required Signing Officer for purposes of acceptance of the Upgrade, and You agree to ensure that each such individual agrees to the Upgrade and accepts the terms of this Agreement before initiating the Upgrade request. Implementation of an Upgrade is subject to the approval of the Financial Institution. a) if Transactions under Direct Services for Small Business require two Signing Officers to authorize, a Signing Officer who has provided evidence of acceptance of this Agreement can view the Account using an Access Terminal, but cannot use Direct Services for Small Business as set out in this Agreement until at least one other required Signing Officer has evidenced their acceptance of this Agreement to Us; or b) if Transactions under Direct Services for Small Business require one Signing Officer to authorize, a Signing Officer who has provided evidence of acceptance of this Agreement can use Direct Services for Small Business as set out in this Agreement. When evidence of this Agreement being accepted by the required number of Signing Officers has been provided to Us, this Agreement will no longer be Provisionally Accepted, the Upgrade will be complete, and this article 3, Upgrading, will no longer apply. We may, in Our sole discretion, revert to the pre-Upgrade status if evidence of acceptance of this Agreement by all required Signing Officers is not provided in a timely manner as required.
Clearcutting Units All trees that meet Utilization Standards within “Clearcutting Units” are designated for cutting.
Grade The employee's grade level. (1-15)
Voice Grade Either an analog signal of 300 to 3000 Hz or a digital signal of 56/64 kilobits per second. When referring to digital Voice Grade service (a 56-64 kbps channel), the terms "DS0" or "sub-DS1" may also be used.
Quantity If Seller delivers more than the quantity of Goods ordered, Buyer may reject all or any excess Goods. Any such rejected Goods shall be returned to Seller at Seller's risk and expense. If Buyer does not reject the Goods and instead accepts the delivery of Goods at the increased or reduced quantity, the Price for the Goods shall be adjusted on a pro-rata basis.
Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.
Check Meters Developer, at its option and expense, may install and operate, on its premises and on its side of the Point of Interconnection, one or more check meters to check Connecting Transmission Owner’s meters. Such check meters shall be for check purposes only and shall not be used for the measurement of power flows for purposes of this Agreement, except as provided in Article 7.4 below. The check meters shall be subject at all reasonable times to inspection and examination by Connecting Transmission Owner or its designee. The installation, operation and maintenance thereof shall be performed entirely by Developer in accordance with Good Utility Practice.
Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.