Grid Compliance Tests Sample Clauses

Grid Compliance Tests. The following test (the “Grid Compliance Tests”) will be conducted by the DBOM Contractor: Active Power Management - Active Power control - Ramp rate test - Measurement of frequency and voltage at connection points (on 132kV side of the transformer) in different operation conditions (start-up, stop, normal operation) TS Voltage Requirements - Power Factor control (Reactive Power capability is part of this test as PF is a matter of Reactive Power) - LVRT simulations - Voltage Emissions and Harmonics calculation undertaken for one week during the Facility Reliability Test - Reactive Power injection Test Signal, Communication and Control - Test of the exchanged signals according to the List of Signals attached to the PPA - Capacity Test, operating the Facility at maximum active power setpoint and at maximum power factor (capacitive and inductive) setpoint. (This test is wind dependent as the Facility will work at Active Power level based on the wind available during the test.) - Prove the immunity to external disturbance of the communication cables by means of datasheet (optical fiber and shielded communication cable) SCHEDULE 11 GOVERNMENT AUTHORISATIONS GOVERNMENT AUTHORISATIONS
AutoNDA by SimpleDocs

Related to Grid Compliance Tests

  • Compliance Review During the Term, Developer agrees to permit the GLO, HUD, and/or a designated representative of the GLO or HUD to access the Property for the purpose of performing Compliance-Monitoring Procedures. In accordance with GLO Compliance-Monitoring Procedures, the GLO or HUD will periodically monitor and audit Developer’s compliance with the requirements of this Agreement, the CDBG-DR Regulations, the CDBG Multifamily Rental Housing Guidelines, and any and all other Governmental Requirements during the Term. In conducting any compliance reviews, the GLO or HUD will rely primarily on information obtained from Developer’s records and reports, on-site monitoring, and audit reports. The GLO or HUD may also consider other relevant information gained from other sources, including litigation and citizen complaints. Attachment G GLO Contract No. 19-097-041-B662 5.04 HAZARDOUS MATERIALS: INDEMNIFICATION

  • CONTRACT COMPLIANCE REQUIREMENT The HUB requirement on this Contract is 0%. The student engagement requirement of this Contract is 0 hours. The Career Education requirement for this Contract is 0 hours. Failure to achieve these requirements may result in the application of some or all of the sanctions set forth in Administrative Policy 3.10, which is hereby incorporated by reference.

  • Compliance Reviews The Department may conduct a compliance review of the Contractor’s security procedures before and during the Contract term to protect Confidential Information.

  • Standards Compliance DNS. Registry Operator shall comply with relevant existing RFCs and those published in the future by the Internet Engineering Task Force (IETF), including all successor standards, modifications or additions thereto relating to the DNS and name server operations including without limitation RFCs 1034, 1035, 1123, 1982, 2181, 2182, 2671, 3226, 3596, 3597, 4343, and 5966. DNS labels may only include hyphens in the third and fourth position if they represent valid IDNs (as specified above) in their ASCII encoding (e.g., “xn--ndk061n”).

  • Requirement to Utilize HUB Compliance Reporting System Pursuant to Texas Administrative Code, Title 34, Part 1, Sections 20.285(f) and 20.287(b), TFC administers monthly administration HSP-PAR compliance monitoring through its HUB Compliance Reporting System commonly known as B2G. PSP and PSP’s subcontractors/subconsultants shall submit required PAR information into the B2G system. Any delay in the timely submission of PAR information into the B2G system will be treated as an invoicing error subject to dispute under Texas Government Code Section 2251.042.

  • Contractor Compliance Contractor represents and warrants to pay, at its sole expense, for all applicable permits, licenses, tariffs, tolls and fees to give all notices and comply with all laws, ordinances, rules and regulations of any governmental entity in conjunction with the performance of obligations under the Contract. Prior to award and during the Contract term and any renewals thereof, Contractor must establish to the satisfaction of the Commissioner that it meets or exceeds all requirements of the Bid/Contract and any applicable laws, including but not limited to, permits, insurance coverage, licensing, proof of coverage for worker’s compensation, and shall provide such proof as required by the Commissioner. Failure to do so may constitute grounds for the Commissioner to cancel or suspend this Contract, in whole or in part, or to take any other action deemed necessary by the Commissioner.

  • INSPECTION/TESTING All Products sold pursuant to this Agreement will be subject to inspection/testing by or at the direction of H- GAC and/or the ordering Customer, either at the delivery destination or the place of manufacture. In the event a Product fails to meet or exceed all requirements of this Agreement, and unless otherwise agreed in advance, the cost of any inspection and/or testing, will be the responsibility of the Contractor.

  • Compliance Audit LEA shall have the right but shall be under no obligation to conduct audit(s), from time to time, of Provider’s records concerning its compliance obligations as set forth in this Article V. Provider shall make such records and other documents available to LEA upon request.

  • Performance Testing 7.2.1 The Design-Builder shall direct and supervise the tests and, if necessary, the retests of the Plant using Design-Builder’s supervisory personnel and the Air Emissions Tester shall conduct the air emissions test, in each case, in accordance with the testing procedures set forth in Exhibit A (the “Performance Tests”), to demonstrate, at a minimum, compliance with the Performance Guarantee Criteria. Owner is responsible for obtaining Air Emissions Tester and for ensuring Air Emissions Tester’s timely performance. Design-Builder shall cooperate with the Air Emissions Tester to facilitate performance of all air emissions tests. Design-Builder shall not be held responsible for the actions of Owner’s employees and third parties involved in the Performance Testing, including but not limited to Air Emissions Tester.

  • Compliance Training ADMINISTRATOR shall make General Compliance Training and Provider Compliance Training, where appropriate, available to Covered Individuals.