Utilization Utilization shall be defined as Trunks Required as a percentage of Trunks In Service. 1 During implementation the Parties will mutually agree on an Economic Centum Call Seconds (ECCS) or some other means for the sizing of this trunk group. 4.6.3.1 In A Blocking Situation (Over-utilization): 4.6.3.1.1 In a blocking situation, CLEC is responsible for issuing ASRs on all two-way Local Only, Local Interconnection, Third Party and Meet Point Trunk Groups and one-way CLEC originating Local Only and/or Local Interconnection Trunk Groups to reduce measured blocking to design objective blocking levels based on analysis of trunk group data. If an ASR is not issued, AT&T-21STATE will issue a TGSR. CLEC will issue an ASR within three (3) business days after receipt and review of the TGSR. CLEC will note “Service Affecting” on the ASR. 4.6.3.1.2 In a blocking situation, AT&T-21STATE is responsible for issuing ASRs on one-way AT&T-21STATE originating Local Only and/or Local Interconnection Trunk Groups to reduce measured blocking to design objective blocking levels based on analysis of trunk group data. If an ASR is not issued, CLEC will issue a TGSR. AT&T- 21STATE will issue an ASR within three (3) business days after receipt and review of the TGSR. 4.6.3.1.3 If an alternate final Local Only Trunk Group or Local Interconnection Trunk Group is at seventy-five percent (75%) utilization, a TGSR may be sent to CLEC for the final trunk group and all subtending high usage trunk groups that are contributing any amount of overflow to the alternate final route. 4.6.3.1.4 If a direct final Meet Point Trunk Group is at seventy-five percent (75%) utilization, a TGSR may be sent to CLEC. If a direct final Third Party Trunk Group is at ninety percent (90%) utilization, a TGSR may be sent to CLEC.
Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)
Underutilization Underutilization of Interconnection Trunks and facilities exists when provisioned capacity of trunks in service for more than six (6) months is greater than the current need. This over-provisioning is an inefficient deployment and use of network resources and results in unnecessary costs. Those situations where more capacity exists than actual usage will be handled in the following manner: a. If a final trunk group is under seventy-five percent (75%) of CCS capacity or a high usage trunk group is under 90% of CCS capacity on a monthly average basis, for each month of any three (3) consecutive months period, either Party may request the issuance of an order to resize the trunk group, which shall be left with not less than twenty-five percent (25%) excess capacity. In all cases POI requirements and grade of service objectives shall be maintained. b. CLEC will send an ASR to CenturyLink to trigger changes to the Local Interconnection Trunk Groups based on capacity assessment.
Diagnostic procedures to aid the Provider in determining required dental treatment.
Clinical 1.1 Provides comprehensive evidence based nursing care and individual case management to a specific group of patients/clients including assessment, intervention and evaluation. 1.2 Undertakes clinical shifts at the direction of senior staff and the Nursing Director including participation on the on-call/after-hours/weekend roster if required. 1.3 Responsible and accountable for patient safety and quality of care through planning, coordinating, performing, facilitating, and evaluating the delivery of patient care relating to a particular group of patients, clients or staff in the practice setting. 1.4 Monitors, reviews and reports upon the standard of nursing practice to ensure that colleagues are working within the scope of nursing practice, following appropriate clinical pathways, policies, procedures and adopting a risk management approach in patient care delivery. 1.5 Participates in xxxx rounds/case conferences as appropriate. 1.6 Educates patients/carers in post discharge management and organises discharge summaries/referrals to other services, as appropriate. 1.7 Supports and liaises with patients, carers, colleagues, medical, nursing, allied health, support staff, external agencies and the private sector to provide coordinated multidisciplinary care. 1.8 Completes clinical documentation and undertakes other administrative/management tasks as required. 1.9 Participates in departmental and other meetings as required to meet organisational and service objectives. 1.10 Develops and seeks to implement change utilising expert clinical knowledge through research and evidence based best practice. 1.11 Monitors and maintains availability of consumable stock. 1.12 Complies with and demonstrates a positive commitment to Regulations, Acts and Policies relevant to nursing including the Code of Ethics for Nurses in Australia, the Code of Conduct for Nurses in Australia, the National Competency Standards for the Registered Nurse and the Poisons Act 2014 and Medicines and Poisons Regulations 2016. 1.13 Promotes and participates in team building and decision making. 1.14 Responsible for the clinical supervision of nurses at Level 1 and/or Enrolled Nurses/ Assistants in Nursing under their supervision.
Commercialization Intrexon shall have the right to develop and Commercialize the Reverted Products itself or with one or more Third Parties, and shall have the right, without obligation to Fibrocell, to take any such actions in connection with such activities as Intrexon (or its designee), at its discretion, deems appropriate.
Hepatitis B Vaccine Where the Hospital identifies high risk areas where employees are exposed to Hepatitis B, the Hospital will provide, at no cost to the employees, a Hepatitis B vaccine.
Utilization Management Contractor shall maintain a utilization management program that complies with applicable laws, rules and regulations, including Health and Safety Code § 1367.01 and other requirements established by the applicable State Regulators responsible for oversight of Contractor.
Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.
Study An application for leave of absence for professional study must be supported by a written statement indicating what study or research is to be undertaken, or, if applicable, what subjects are to be studied and at what institutions.