Lighting Fittings Sample Clauses

Lighting Fittings. Lighting fittings shall be of the type appropriate for purpose. The type references used shall be repeated in the technical schedules and on the drawings to be prepared by the Contractor. Illustrations and/or samples of all lighting fittings which the Contractor proposes to purchase shall be submitted to the Engineer for approval before issuing any sub-orders. Lighting fittings for interior and exterior use shall be manufactured and tested in accordance with the appropriate sections of IEC 60598 and together with all components shall be suitable for service and operation in the climate specified. Lighting fittings for use in hazardous areas shall be designed and certified as suitable for use within the area according to the Zone or Division classification and the nature of the inflammable gas, liquid, vapour or dust concerned. Location Service Illumination Type of Fittings Type of Control Offices in general 500 C Local switch Conference/ Training/ Meeting Room 600 E Push bottom / Dimmer Computer and Electronic Equipment Room 500/800 C Local switch Toilets 200 A, J Local switch Locker Rooms 100 A Local switch Kitchen, Kitchenette 500 C Push bottom / Local switch Canteen 200 C Local switch Maintenance Workshop / Repair Area 200/300 F, G Push bottom / Local switch Battery room / Paint Shop / Welding Shop 200 B Push bottom / Local switch Gate-In and Gate-Out 100 L Push bottom / Local switch Pump houses / Fuelling station / Power Station 200 A Push bottom / Local switch Indoor Areas not specifically listed 200 A Local switch Outdoor Areas not specifically listed 50 L Photo-cell / Local switch Building’s Corridor and Stairway 200 D, K Local switch Table 13-2: Service Illumination Levels Each fitting shall be complete with all lamp holders, control gear, internal wiring, fused terminal block, earth terminal and reflectors or diffusers as specified. The design of each fitting shall be such as to minimise the effect of glare and such that the ingress of dust, flies and insects is prevented. Preference shall be given to fittings with low maintenance and high efficiency. Fluorescent lighting fittings shall be of the high efficiency electronic type having hermetically sealed ballasts of the low noise level pattern. The power factor of the fitting and control gear shall not be less than 0.90. The control gear for use with fluorescent lamps shall incorporate power-factor correction and interference suppression capacitors. Chokes shall be impregnated and solidly filled w...
AutoNDA by SimpleDocs
Lighting Fittings. 6.11.2. Where conductors are required to be drawn through tube or channel loading to the fitting, the tube or channel must be free from sharp angles or projecting edge and of such size as will enable them to be wired with the conductors used for the final circuit without removing the braiding or tapping. As far as possible all tubes or channels should be of sufficient size to permit of looping back. Non-current carrying metal parts of each lighting fitting should be bonded to an earth continuity conductor.

Related to Lighting Fittings

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.

  • Fittings 3.2.1 Landing gear support structure and attachment fitting

  • Bathrooms Record the number of bathrooms found on the concerned premises. (7) Common Areas. Furnish the number of common or communal areas available to the Roommates on the premises. (8) Private Areas. Report the number of private rooms or areas found on the premises that the Roommates can access and utilize (alone). III. Term (9)

  • Toilets Papers, dust, cobwebs, peels, cans/bottles, cigarette butts, excrement on floor, bad smells, water pools, leaking sewage, rodents, animals (dead or alive), overflowing sanitary bins. 0 = NOT APPLICABLE 1 = UNACCEPTABLE (Toilets out of order. Toilets not cleaned on daily basis.) 2 = POOR (Toilets cleaned, but still visible signs of dirt, e.g. dust, cobwebs.) 3 = GOOD (Obvious sign that toilets are cleaned daily.) 4 = EXCELLENT (Extra effort is put in to ensure cleanliness, e.g. using detergents.)

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.

  • Plumbing fixtures and appliances shall be used only for the purposes for which designed, and no sweepings, rubbish, rags or other unsuitable material shall be thrown or deposited therein. Damage resulting to any such fixtures or appliances from misuse by a tenant or its agents, employees or invitees, shall be paid by such tenant.

  • Interior (a) Ceilings, sidewalls and bulkhead panels shall be clean and free of cracks and stains;

  • Restrooms The restrooms, toilets, urinals, vanities and the other apparatus shall not be used for any purpose other than that for which they were constructed, and no foreign substance of any kind whatsoever shall be thrown therein. The expense of any breakage, stoppage or damage resulting from the violation of this rule shall be borne by the Tenant whom, or whose employees or invitees, shall have caused it.

  • Electrical Provide drawings for the following systems:

  • Outdoor Lighting 3.8.1 Lighting shall be directed to driveways, parking areas, loading area, building entrances and walkways and shall be arranged so as to divert the light away from streets, adjacent lots and buildings.

Time is Money Join Law Insider Premium to draft better contracts faster.