Line Specifications Sample Clauses

Line Specifications. All Lines and the installation thereof shall comply with the reasonable specifications and requirements established by Landlord from time to time.
AutoNDA by SimpleDocs
Line Specifications. All Lines shall comply with the specifications ------------------- and requirements established by Landlord from time to time, including without limitation the following: (a) Tenant's vertical riser Lines shall be fiber optic or, subject to the requirements of clause (c) below, copper, (b) if Tenant at any time uses any equipment that may create an electromagnetic field exceeding the normal insulation ratings of ordinary twisted pair riser cable or cause radiation higher than normal background radiation, the Lines therefor (including riser lines) shall be appropriately insulated to prevent such excessive electromagnetic fields or radiation (and such insulation shall not be provided by the use of additional unused twisted pair lines), (c) no copper communications wire shall be installed in the same riser sleeve, chaseway or other enclosure in close proximity with electrical wire, no PVC-coated lines shall be installed under any circumstances, and all Lines not in conduit shall be plenum rated, (d) all Lines shall be installed appropriately underground, within walls, above suspended ceilings, within sleeves (which, in the case of vertical or horizontal fiber Lines, shall be through plenum-rated innerduct), pipes, conduits or horizontal chaseways or otherwise as Landlord shall require, and in no event shall be visible to tenants or occupants of the Building, (e) each riser Line installed by or for Tenant shall be tied off and securely anchored at each floor of the building, and any metal clamps or other metal equipment shall be properly grounded, (f) no multiplexers, PBX mainframes, file servers, key system units or any other equipment or items of any kind shall be installed in any wire closet except 25 pair 66 Block connectors, and then only if expressly approved or required by Landlord in writing (in the exercise of Landlord's reasonable judgment), (g) appropriate ground protectors shall be used to protect against over-voltage or overcurrent of 600 volts or greater at the Building's main telephone equipment room, and (h) all installation, modification, maintenance, replacements, and removal of the Lines shall comply with such inside wire standards as Landlord shall adopt from time to time.

Related to Line Specifications

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • The Specifications The Specifications are that portion of the Contract Documents consisting of the written requirements for materials, equipment, systems, standards and workmanship for the Work, and performance of related services.

  • Technical Specifications and Drawings a) The Goods and Related Services supplied under this Contract shall conform to the technical specifications and standards mentioned in Section VI, Schedule of Requirements and, when no applicable standard is mentioned, the standard shall be equivalent or superior to the official standards whose application is appropriate to the Goods' country of origin. b) The Supplier shall be entitled to disclaim responsibility for any design, data, drawing, specification or other document, or any modification thereof provided or designed by or on behalf of the Procuring Entity, by giving a notice of such disclaimer to the Procuring Entity. c) Wherever references are made in the Contract to codes and standards in accordance with which it shall be executed, the edition or the revised version of such codes and standards shall be those specified in the Schedule of Requirements. During Contract execution, any changes in any such codes and standards shall be applied only after approval by the Procuring Entity and shall be treated in accordance with GCC Clause 33.

  • Packing Specifications 7.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • General specifications For the purpose of this Regulation, the vehicle shall fulfil the following requirements:

  • ODUF Packing Specifications 6.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!