Common use of Meter Installation and Testing Clause in Contracts

Meter Installation and Testing. Seller shall cause the installation, maintenance, operation and replacement (as needed) of a meter to be used as the Electric Revenue Meter and back-up meters, in accordance with the Transmission Provider’s metering protocols, at the Electrical Delivery Point to determine the amount of the Energy produced by the Units and delivered to the Electrical Delivery Point, [and the Gas Meter and back-up meters, in accordance with the requirements of the interconnecting pipeline, at the Gas Delivery Point, to determine the amount of Gas delivered to the Gas Delivery Point, in each case] at its sole cost and expense. To the extent necessary to isolate data related to each Unit, Seller shall cause the installation, maintenance, operation and replacement (as needed) of electrical [and/or Gas] submeters, at its sole cost and expense; provided that each such submeter shall be of revenue quality and sufficient for the purposes of providing the data contemplated by this Agreement. Each [Gas Meter and] Electric Revenue Meter shall be locked or sealed only by, and the lock or seal shall be broken only by, the interconnecting utility or Transmission Provider, as applicable. All of the submeters will be locked or sealed by both Parties, which locks or seals will only be broken by both Parties for inspection, testing or adjustment. The meters shall meet all specifications of the Transmission Provider [or interconnecting Gas pipeline, as applicable], and all meters and submeters shall be tested annually by Seller, who shall provide Buyer with not less than 14 days prior Notice of such tests. Testing procedures and standards for submeters shall be the same as for a comparable utility-owned meter. Buyer will have the right to have a representative present during such tests. [For facilities other than Gas-fired facilities, omit the bracketed language].

Appears in 5 contracts

Samples: Power Purchase and Sale Agreement, Power Purchase and Sale Agreement, Power Purchase and Sale Agreement

AutoNDA by SimpleDocs

Meter Installation and Testing. Seller shall shall, at its sole cost and expense, cause the installation, maintenance, operation and replacement (as needed) of a meter to be used as (i) the Electric Revenue Meter and back-up meters, in accordance with the Transmission Provider’s metering protocols, at the Electrical Delivery Point to determine the amount of the Energy produced by the Units and delivered to the Electrical Delivery Point, [and (ii) the Gas Meter and back-up meters, in accordance with the requirements of the interconnecting pipeline, at the Gas Delivery Point, to determine the amount of Gas delivered to the Gas Delivery Point, in each case] at its sole cost and expense. To the extent necessary to isolate data related to each Unit, Buyer may in its discretion, require Seller shall to cause the installation, maintenance, operation and replacement (as needed) of electrical [and/or Gas] Gas submeters, at its Seller’s sole cost and expense; provided that each such submeter shall be of revenue quality and sufficient for the purposes of providing the data contemplated by this Agreement. Each [Gas Meter and] and Electric Revenue Meter shall be locked or sealed only by, and the lock or seal shall be broken only by, the interconnecting utility or Transmission Provider, as applicable. All Unless otherwise specified by Buyer, all of the submeters will be locked or sealed by both Parties, which locks or seals will only be broken by both Parties for inspection, testing or adjustment. The meters shall meet all specifications of the Transmission Provider [or interconnecting Gas pipeline, as applicable], and all meters and submeters shall be tested annually by Seller, who shall provide Buyer with not less than 14 fourteen (14) days prior Notice of such tests. Testing procedures and standards for submeters shall be the same as for a comparable utility-owned meter. Buyer will have the right to have a representative present during such tests. [For facilities other than Gas-fired facilities, omit the bracketed language].

Appears in 3 contracts

Samples: Tolling Power Purchase Agreement, Tolling Power Purchase Agreement, Tolling Power Purchase Agreement

Meter Installation and Testing. Seller shall cause the installation, maintenance, operation and replacement (as needed) of a meter to be used as the Electric Revenue Meter and back-up meters, in accordance with the Transmission Provider’s metering protocols, at the Electrical Delivery Point to determine the amount of the Energy produced by the Units and delivered to the Electrical Delivery Point, [and the Gas Meter and back-up meters, in accordance with the requirements of the interconnecting pipeline, at the Gas Delivery Point, to determine the amount of Gas delivered to the Gas Delivery Point, in each case] case at its sole cost and expense. To the extent necessary to isolate data related to each Unit, Seller shall cause the installation, maintenance, operation and replacement (as needed) of electrical [and/or Gas] Gas submeters, at its sole cost and expense; provided that each such submeter shall be of revenue quality and sufficient for the purposes of providing the data contemplated by this Agreement. Each [Gas Meter and] and Electric Revenue Meter shall be locked or sealed only by, and the lock or seal shall be broken only by, the interconnecting utility or Transmission Provider, as applicable. All Unless otherwise specified by Buyer, all of the submeters will be locked or sealed by both Parties, which locks or seals will only be broken by both Parties for inspection, testing or adjustment. The meters shall meet all specifications of the Transmission Provider [or interconnecting Gas pipeline, as applicable], and all meters and submeters shall be tested annually by Seller, who shall provide Buyer with not less than 14 days prior Notice of such tests. Testing procedures and standards for submeters shall be the same as for a comparable utility-owned meter. Buyer will have the right to have a representative present during such tests. [For facilities other than Gas-fired facilities, omit the bracketed language].

Appears in 2 contracts

Samples: Power Purchase and Sale Agreement, Power Purchase and Sale Agreement

AutoNDA by SimpleDocs

Meter Installation and Testing. Seller shall shall, at its sole expense, cause the installation, maintenance, operation and replacement (as needed) of a meter to be used as the Electric Revenue Meter and back-up meters, in accordance with the Transmission Provider’s metering protocols, at the Electrical Delivery Point to determine measure the amount of the Delivered Discharge Energy produced by the Units and delivered to the Electrical Delivery Point, [and the Gas Meter and back-up meters, in accordance with the requirements of the interconnecting pipeline, at the Gas Delivery Point, to determine the amount of Gas delivered to the Gas Delivery Point, in each case] at its sole cost and expenseCharging Energy. To the extent necessary to isolate data related to each Unit, Buyer may in its discretion, require Seller shall to cause the installation, maintenance, operation and replacement (as needed) of electrical [and/or Gas] submeters, at its Seller’s sole cost and expense; provided that each such submeter shall be of revenue quality and sufficient for the purposes of providing the data contemplated by this Agreement. Each [Gas Meter and] Electric Revenue Meter shall be locked or sealed only by, and the lock or seal shall be broken only by, the interconnecting utility or Transmission Provider, as applicable. All of the submeters will be locked or sealed by both Parties, which locks or seals will only be broken by both Parties for inspection, testing or adjustment. The meters shall meet all specifications of the Transmission Provider [or interconnecting Gas pipelineProvider, as applicable], and all meters and submeters shall be tested annually by Seller, who shall provide Buyer with not less than 14 fourteen (14) days prior Notice of such any tests, inspection, or adjustment of a meter or submeter. Testing procedures and standards for submeters shall will be the same as for a comparable utility-owned meter. Buyer will have the right to have a representative present during such tests, inspections, or adjustments. [For facilities other than GasWhether or not Buyer elects to observe such tests, inspections or adjustments, Seller will provide Buyer with details of the results, including an as-fired facilities, omit the bracketed language]found and as-left calibration certificate.

Appears in 1 contract

Samples: Consent and Agreement

Time is Money Join Law Insider Premium to draft better contracts faster.