Common use of Pressures Clause in Contracts

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig at the inlet meter of the screw compressor applicable to each Delivery Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer from time to time: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 4 contracts

Samples: Gathering Services Agreement, Gathering Services Agreement, Gathering Services Agreement

AutoNDA by SimpleDocs

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig, but capable of a minimum pressure of 2 to 3 psig at the inlet meter of the screw compressor applicable to each Delivery Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer from time to time: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain Not contain more than five (5) pounds of entrained water vapor per millioncubit feet and no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 1 contract

Samples: Gathering Services Agreement

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig, but capable of a minimum pressure of 2 to 3 psig at the inlet meter of the screw compressor applicable to each Delivery Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer from time to time: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain Not cContain more than five (5) pounds of entrained water vapor per million cubic feet and no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 1 contract

Samples: Gathering Services Agreement

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig, but capable of a minimum pressure of 2 to 3 psig at the inlet meter of the screw compressor and/or an average design suction pressure of 80 psig at the inlet meter of the reciprocating compressor applicable to each Delivery Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer from time to timetime to comply with downstream pipeline specifications: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 1 contract

Samples: Gathering Services Agreement

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig, but capable of a minimum pressure of 2 to 3 psig at the inlet meter of the screw compressor and/or an average design suction pressure of 80 psig at the inlet meter of the reciprocating compressor applicable to each Delivery Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer from time to timetime to comply with downstream pipeline specifications: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 1 contract

Samples: Gathering Services Agreement

AutoNDA by SimpleDocs

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig at the inlet meter of the screw compressor applicable to each Delivery Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer Gathererthe owner or operator of the Fort Union Gathering Header from time to time: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain Not contain more than five (5) pounds of entrained water vapor per millioncubit feet and no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 1 contract

Samples: Gathering Services Agreement

Pressures. Gatherer shall install and maintain compression facilities which have an average design suction pressure of 5 psig at the inlet meter of the screw compressor applicable to each Delivery Receipt Point in accordance with the provisions of the Facilities Development Plan attached hereto as Exhibit "B". Notwithstanding anything to the contrary herein, Gatherer and Owner agree that the pressures maintained at the compression facilities and at the wellhead(s) will be adjusted as reasonable and necessary to optimize production with due consideration for the design and operational capabilities and limitations of the compressor units. 6.1. The Gas delivered at the Receipt Point(s) shall be commercially free of gum, gum-forming constituents, gasoline, and other solid or liquid matter that may become separated from the Gas during Gathering thereof and shall conform to the Specifications as the same may be amended or supplemented by Gatherer from time to time: (a) Have a total Gross Heating Value of not less than 950 Btu's per cubic foot; (b) Be commercially free of all dust, non-vaporous hydrocarbon liquids, suspended matter, all gums and gum forming constituents and any other objectionable substances; (c) Contain not more than twenty (20) grains of total sulfur, nor more than one-fourth (1/4) grain of hydrogen sulfide per one hundred (100) standard cubic feet; (d) Contain not more than four percent (4%) by volume of carbon dioxide (CO2); (e) Have no greater than 10 ppm of oxygen; (f) Not contain more than six percent (6%) by volume of total inerts; (g) Have a temperature of not less than forty (40) degrees Fahrenheit nor greater than one hundred and twenty (120) degrees Fahrenheit; (h) Contain Not contain more than five (5) pounds of entrained water vapor per million cubic feet and no free water; and (i) Have a hydrocarbon dew point no greater than twenty-five (25) degrees Fahrenheit.

Appears in 1 contract

Samples: Gathering Services Agreement

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!