Measuring Equipment and Testing Sample Clauses

Measuring Equipment and Testing. 5.1 Buyer, or its designee, shall maintain and operate at its own expense the measuring station(s) at the Point(s) of Delivery through which the quantity of gas purchased and sold hereunder shall be measured. Seller may install, maintain and operate, at its own expense, such check measuring equipment as desired; provided, that such equipment shall be installed so as not to interfere with the operation of Buyer's or its designee's measuring equipment. 5.2 The measuring equipment shall be constructed, installed and operated in accordance with the following depending on the type of meters used: a. Orifice Meters—in accordance with ANSI/API 2530 (American Gas Association Report No. 3), Orifice Metering of Natural Gas and Other Hydrocarbon Fluids, Second Edition, dated September 1985, and any subsequent amendments. revisions or modifcations thereof and shall include the use of flange connections. Should gas pulsation problems occur upstream of the Point(s) of Delivery, Seller or its designee, or down stream of the Point(s) of Delivery, Buyer or its designee, shall take whatever steps necessary to mitigate such pulsation. b. Positive Meters—in accordance with the American Gas Association Measurement Committee Report No. 6 (American Gas Association Report No. 6) dated January 1971, and any subsequent amendments, revisions or modifications thereof. c. Turbine Meters—in accordance with the American Gas Association Measurement Committee Report No. 7 (American Gas Association Report No. 7), First Revision, dated November 1984, and any subsequent amendments, revisions or modifications thereof. d. Electronic Transducers and Flow Computers (solar and otherwise)—in accordance with the applicable American Gas Association standards, including but not limited to American Gas Association Measurement Committee Report Nos. 3, 5, 6 and 7 and any subsequent amendments, revisions, or modifications thereof. Notwithstanding anything contained in this Section to the contrary, Buyer or its designee shall not be required to replace or make any alterations to its measuring equipment as a result of any subsequent amendments, revisions or modifications of the American Gas Association Reports cited in Subparagraphs (a) through (d) of this Section, unless the Parties mutually agree to such replacement or alteration. 5.3 Buyer shall give reasonable notice to Seller in order that Seller may have a representative present to observe any cleaning, changing, repairing, inspecting, testing, calib...
AutoNDA by SimpleDocs
Measuring Equipment and Testing. Section 1. Measuring equipment and testing shall be governed by the Operating Agreement.
Measuring Equipment and Testing. 5.1 Buyer, or its designee, shall maintain and operate at its own expense the measuring station(s) at the Point(s) of Delivery through which the quantity of gas purchased and sold hereunder shall be measured. Seller may install, maintain and operate, at its own expense, such check measuring equipment as desired; provided, that such equipment shall be installed so as not to interfere with the operation of Buyer's or its designee's measuring equipment. 5.2 The measuring equipment shall be constructed, installed and operated in accordance with the following depending on the type of meters used: a. Orifice Meters—in accordance with ANSI/API 2530 (American Gas Association Report No. 3), Orifice Metering of Natural Gas and Other Hydrocarbon Fluids, Second Edition, dated September 1985, and any subsequent amendments. revisions or modifcations thereof and shall include the use of flange connections. Should gas pulsation problems occur upstream of the Point(s) of Delivery, Seller or its designee, or down stream of the Point(s) of Delivery, Buyer or its designee, shall take whatever steps necessary to mitigate such pulsation.
Measuring Equipment and Testing. (a) The Gas delivered to NSLEM at the Receipt Point(s) and the Gas redelivered to Producer at the Delivery Point(s) will be measured by meters of standard type that will be installed, operated and maintained by Transporters (or its designee). Measurement devices and equipment will be tested and adjusted for accuracy on a regular schedule by Transporters (or its designee). (b) If adequate metering facilities are already in existence at the Receipt and/or Delivery Point(s) hereunder, such existing metering facilities may be used for so long as, in Transporters' sole opinion, they remain adequate. However, if new or additional facilities ever are required to effectuate the receipt or delivery of Gas hereunder, Producer will be responsible for the cost of such facilities. If Producer desires new or continued service hereunder at any such point(s), Producer will enter into a Facilities Construction Agreement with Transporters to provide and install the necessary facilities. NSLEM will not be obligated to expend any monies to install, repair and/or replace any facilities located at the Receipt and/or Delivery Point(s) hereunder. (c) Producer will have access to the metering equipment at all times, but the maintenance, calibration and adjustment of the Delivery Point and Receipt Point metering equipment, will be done only by Transporters (or its designee). Records from all such metering equipment will remain the property of Transporters (or its designee) and will be kept on file by NSLEM for a period of not less than two years. However, upon request of Producer, NSLEM will make available to Producer volume records from the metering equipment, together with calculations therefrom, for inspection and verification, subject to return to NSLEM within 30 days after receipt thereof. (d) The measurement of Gas for the purpose of this Agreement will be by Transporters’ (or its designee’s) Receipt Point(s) and Delivery Point(s) meters only, except as hereinafter specifically provided. The meters, check meters, instruments and equipment installed by each Party will be subject at all reasonable times to inspection or examination by the other Party, but the calibration and adjustment thereof will be done only by the installing Party. (e) Each Party will give to the other Party notice of the time of all tests of such notifying Party's meters at the Delivery Point(s) sufficiently in advance of such tests so that the other Party may conveniently have its representatives present;...
Measuring Equipment and Testing. 8 VIII Measuring Specifications............................ 8
Measuring Equipment and Testing. 15 6.1 Equipment .................................................................................................................. 15 6.2 Calibration and Tests of Meters ..................................................................................15 6.3 Access to Meters and Records ....................................................................................15 6.4
Measuring Equipment and Testing 
AutoNDA by SimpleDocs

Related to Measuring Equipment and Testing

  • MEASURING EQUIPMENT 1. Seller will maintain and operate, atlts own, expense and atthe point of delivery of gas hereunder, a meter or meters and othernecessary equipment by which the volume of gas delivered hereunder shall be measured. Such meters and equipment shall remain the property of the Seller. 2. Buyer agrees lo furnish to Seller electricity for operating Seller's meters, at not cost to Seller. 3. Buyer hereby grants to Seller suitable rlghts-0f-way and easements necessary or Incidental for the installatioo, maintenance, operation and removal of pipeline and other facilities together with rights ofingress thereto and egress there from at all times and hereby agrees to deliver to Seller, for the sum of one dollar ($1.00), an appropriate instrument or grant defining such rights and easements located on Buyer's planlslte. 4. Buyer may install, maintain and operate such check measuring equipment, Including arecording gravltometer and calorimeter as it shall desire, provided that such equipment shall be so installed so as not to Interfere with the operation of Seller's measuring equipment at or near the point of deliver. However, all xxxxxxxx to the Buyer shall be based on the metering of the Seller, subject only to the provisions of Paragraph 8 of this Article. 5. Each party shall have the right to be present at the time of any installing, reading, cleaning, changing, repairing, Inspecting, testing, calibrating, or adjusting done In connection with the other's measuring equlpme!lt used in measuring deliveries hereunder and each party shall advise the other of any Intended major maintenance operation sufficiently in advance in order that the other party may conveniently have its representative present. 6. All installatioo of measuring equipmenL applying to or effecting deliveries hereunder, shall be rnade in such manner as to perrnit an accurate detenninalion of the quantity of gas delivered and ready verification of the accuracy of measurement Orifice meter Installations, If used, shall oonforrn lo the recommendation for design and lnstallatioo contained in the Gas Measurement Commiltee Report No. 3 to the American Gas Association published April, 1955, and any modificatioos and amendments thereof and shall include the use of flange connections. 7. Measurement on Seller's meter or meters shall be conclusive of both parties except where the meter Is defective or fails to register, or if found in E)rror, in either of which case Seller shall repair or replace the meter and the quantity of gas delivered while the meter was out of order or failed to register shall be estimated: (a) By using the registration of any check meter If installed and accurately registering, or, In the absence of (a): (b) By correcting the error If the percentage of error by calibration, test or mathematical calculation, or, in the absence of both (a) and (b) then: (c) By estimating the quantity of delivery from deliveries during periods under similar oonditions when the meter was registering actUrately; and an appropriate billing adjusbnentshall be made In accordance with the current Rules and Regulations governing gas systems issued by the Commission. 8. Seller will maintain its meters in .good order and to this end Wiii make periodic tests of its meters pursuant to the current Rules and Regulations governing gas systems issued by the Commission, or at such shorter intervals as seem to Seller desirable. lfBuyer Is dissatisfied with the accuracy at eny time, it may call upon Seller to have Iha meter tested in accordance with all regulatioos relating to such tests and results of such tesls as found in the current Rules and Regulations governing gas systems issued by the Commission. 9. Each party shall preserve all records for aperiod of at least two (2) years.

  • Testing of Metering Equipment Connecting Transmission Owner shall inspect and test all of its Metering Equipment upon installation and at least once every two (2) years thereafter. If requested to do so by NYISO or Developer, Connecting Transmission Owner shall, at Developer’s expense, inspect or test Metering Equipment more frequently than every two (2) years. Connecting Transmission Owner shall give reasonable notice of the time when any inspection or test shall take place, and Developer and NYISO may have representatives present at the test or inspection. If at any time Metering Equipment is found to be inaccurate or defective, it shall be adjusted, repaired or replaced at Developer’s expense, in order to provide accurate metering, unless the inaccuracy or defect is due to Connecting Transmission Owner’s failure to maintain, then Connecting Transmission Owner shall pay. If Metering Equipment fails to register, or if the measurement made by Metering Equipment during a test varies by more than two percent from the measurement made by the standard meter used in the test, Connecting Transmission Owner shall adjust the measurements by correcting all measurements for the period during which Metering Equipment was in error by using Developer’s check meters, if installed. If no such check meters are installed or if the period cannot be reasonably ascertained, the adjustment shall be for the period immediately preceding the test of the Metering Equipment equal to one-half the time from the date of the last previous test of the Metering Equipment. The NYISO shall reserve the right to review all associated metering equipment installation on the Developer’s or Connecting Transmission Owner’s property at any time.

  • Metering Equipment 13.01. Utility will furnish, install, own and maintain metering equipment capable of measuring the flow of kilowatt-hours (kWh) of energy. The Customer's service associated with the CRG will be metered at a single metering point. The metering equipment will measure energy delivered by Utility to Customer and also measure energy delivered by Customer to Utility. Customer agrees to provide safe and reasonable access to the premises for installation of this equipment and its future maintenance or removal.

  • Equipment and Tools 40.01 The Employer will make available all necessary tools and equipment it requires for the performance of work assignments at no cost to the employees. Such tools and equipment will remain the property of the Employer and the employees will be required to take reasonable care of this property and may be required to sign out certain equipment and tools.

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • Meter Testing Company shall provide at least twenty-four (24) hours' notice to Seller prior to any test it may perform on the revenue meters or metering equipment. Seller shall have the right to have a representative present during each such test. Seller may request, and Company shall perform, if requested, tests in addition to the every fifth-year test and Seller shall pay the cost of such tests. Company may, in its sole discretion, perform tests in addition to the fifth year test and Company shall pay the cost of such tests. If any of the revenue meters or metering equipment is found to be inaccurate at any time, as determined by testing in accordance with this Section 10.2 (Meter Testing), Company shall promptly cause such equipment to be made accurate, and the period of inaccuracy, as well as an estimate for correct meter readings, shall be determined in accordance with Section 10.3 (Corrections).

  • Computer Equipment Recycling Program If this Contract is for the purchase or lease of computer equipment, then Contractor certifies that it is in compliance with Subchapter Y, Chapter 361 of the Texas Health and Safety Code related to the Computer Equipment Recycling Program and the Texas Commission on Environmental Quality rules in 30 TAC Chapter 328.

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Equipment and Materials CONTRACTOR shall provide all equipment, materials, and supplies necessary for the performance on the Agreement except:

  • REPAIRED OR REPLACED PARTS / COMPONENTS Where the Contractor is required to repair, replace or substitute Product or parts or components of the Product under the Contract, the repaired, replaced or substituted Products shall be subject to all terms and conditions for new parts and components set forth in the Contract including Warranties, as set forth in the Additional Warranties Clause herein. Replaced or repaired Product or parts and components of such Product shall be new and shall, if available, be replaced by the original manufacturer’s component or part. Remanufactured parts or components meeting new Product standards may be permitted by the Commissioner or Authorized User. Before installation, all proposed substitutes for the original manufacturer’s installed parts or components must be approved by the Authorized User. The part or component shall be equal to or of better quality than the original part or component being replaced.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!