We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.
For more information visit our privacy policy.Processing Transactions 2 2.1 Timely Pricing and Orders.................................... 2 2.2
Scope of Interconnection Service 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.
Provisional Interconnection Service Prior to the completion of the Large Facility Interconnection Procedures and prior to completion of requisite Attachment Facilities, Distribution Upgrades, System Upgrade Facilities, System Distribution Upgrades, or System Protection Facilities, the Developer may request an evaluation for Provisional Interconnection Service. NYISO, in conjunction with the Connecting Transmission Owner, shall determine, through available studies or additional studies as necessary, whether stability, short circuit, thermal, and/or voltage issues would arise if the Developer interconnects without modifications to the Large Generating Facility or the New York State Transmission System (or Distribution System as applicable). NYISO, in conjunction with the Connecting Transmission Owner, shall determine whether any Attachment Facilities, Distribution Upgrades, System Upgrade Facilities, System Deliverability Upgrades, or System Protection Facilities, which are necessary to meet Applicable Laws and Regulations, Applicable Reliability Standards, and Good Utility Practice, are in place prior to the commencement of interconnection service from the Large Facility. Where available studies indicate that the Attachment Facilities, Distribution Upgrades, System Upgrade Facilities, System Deliverability Upgrades, or System Protection Facilities are required for the interconnection of a new, modified and/or expanded Large Facility but such facilities are not currently in place, NYISO, in conjunction with the Connecting Transmission Owner, will perform a study, at the Developer’s expense, to confirm the facilities that are required for Provisional Interconnection Service. The maximum permissible output of the Large Facility in the Provisional Large Facility Interconnection Agreement shall be studied, at the Developer’s expense, and updated annually. The NYISO shall issue the study’s findings in writing to the Developer and Connecting Transmission Owner(s). Following a determination by NYISO, in conjunction with the Connecting Transmission Owner, that the Developer may reliably provide Provisional Interconnection Service, NYISO shall tender to the Developer and Connecting Transmission Owner, a Provisional Large Facility Interconnection Agreement. NYISO, Developer, and Connecting Transmission Owner may execute the Provisional Large Facility Interconnection Agreement, or the Developer may request the filing of an unexecuted Provisional Large Facility Interconnection Agreement with the Commission. The Developer shall assume all risk and liabilities with respect to changes between the Provisional Large Facility Interconnection Agreement and the Large Generator Interconnection Agreement, including changes in output limits and the cost responsibilities for the Attachment Facilities, System Upgrade Facilities, System Deliverability Upgrades, and/or System Protection Facilities.
Trunk Types 2.2.1 In interconnecting their networks pursuant to this Attachment, the Parties will use, as appropriate, the following separate and distinct trunk groups: 2.2.1.1 Interconnection Trunks for the transmission and routing of Reciprocal Compensation Traffic, translated LEC IntraLATA toll free service access code (e.g., 800/888/877) traffic, and IntraLATA Toll Traffic, between their respective Telephone Exchange Service Customers, Tandem Transit Traffic, and, Measured Internet Traffic, all in accordance with Sections 5 through 8 of this Attachment; 2.2.1.2 Access Toll Connecting Trunks for the transmission and routing of Exchange Access traffic, including translated InterLATA toll free service access code (e.g., 800/888/877) traffic, between Ymax Telephone Exchange Service Customers and purchasers of Switched Exchange Access Service via a Verizon access Tandem in accordance with Sections 9 through 11 of this Attachment; and 2.2.1.3 Miscellaneous Trunk Groups as mutually agreed to by the Parties, including, but not limited to: (a) choke trunks for traffic congestion and testing; and, (b) untranslated IntraLATA/InterLATA toll free service access code (e.g. 800/888/877) traffic. 2.2.2 Other types of trunk groups may be used by the Parties as provided in other Attachments to this Agreement (e.g., 911/E911 Trunks) or in other separate agreements between the Parties (e.g., directory assistance trunks, operator services trunks, BLV/BLVI trunks or trunks for 500/555 traffic). 2.2.3 In accordance with the terms of this Agreement, the Parties will deploy One-Way Interconnection Trunks (trunks with traffic going in one direction, including one-way trunks and uni-directional two-way trunks) and/or Two-Way Interconnection Trunks (trunks with traffic going in both directions). 2.2.4 Ymax shall establish, at the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA, separate Interconnection Trunk group(s) between such POI(s) and each Verizon Tandem in a LATA with a subtending End Office(s) to which Ymax originates calls for Verizon to terminate. 2.2.5 In the event the volume of traffic between a Verizon End Office and a technically feasible Point of Interconnection on Verizon’s network in a LATA, which is carried by a Final Tandem Interconnection Trunk group, exceeds (a) the Centium Call Seconds (Hundred Call Seconds) busy hour equivalent of one (1) DS1 at any time; (b) 200,000 minutes of use for a single month; and/or; (c) 600 busy hour Centium Call Seconds (BHCCS) of use for a single month: (i) if One-Way Interconnection Trunks are used, the originating Party shall promptly establish new or augment existing End Office One-Way Interconnection Trunk groups between the Verizon End Office and the technically feasible Point of Interconnection on Verizon’s network; or,
Fund/SERV Transactions If the parties choose to use the National Securities Clearing Corporation’s Mutual Fund Settlement, Entry and Registration Verification (“Fund/SERV”) or any other NSCC service, the following provisions shall apply: The Company and the Fund or its designee will each be bound by the rules of the National Securities Clearing Corporation (“NSCC”) and the terms of any NSCC agreement filed by it or its designee with the NSCC. Without limiting the generality of the following provisions of this section, the Company and the Fund or its designee will each perform any and all duties, functions, procedures and responsibilities assigned to it and as otherwise established by the NSCC applicable to Fund/SERV, the Mutual Fund Profile Service, the Networking Matrix Level utilized and any other relevant NSCC service or system (collectively, the “NSCC Systems”). Any information transmitted through the NSCC Systems by any party or its designee to the other or its designee and pursuant to this Agreement will be accurate, complete, and in the format prescribed by the NSCC. Each party or its designee will adopt, implement and maintain procedures reasonably designed to ensure the accuracy of all transmissions through the NSCC Systems and to limit the access to, and the inputting of data into, the NSCC Systems to persons specifically authorized by such party. On each day on which the New York Stock Exchange is open for trading and on which the Fund calculates its net asset value pursuant to the rules of the SEC (“Business Day”), the Company shall aggregate and calculate the net purchase and redemption orders for each Account received by the Company by the close of the New York Stock Exchange (generally, 4:00 p.m. Eastern Time) (the “Close of Trading”) on the Business Day. The Company shall communicate to the Fund or its designee for that Business Day, by Fund/SERV, the net aggregate purchase or redemption orders (if any) for each Account received by the Close of Trading on such Business Day (the “Trade Date”) no later than 7:00 a.m. Eastern Time (or such other time as may be agreed by the parties from time to time) (the “Fund/SERV Transactions Deadline”) on the Business Day following the Trade Date. All such aggregated orders communicated to the Fund or its designee by the Fund/SERV Transactions Deadline on the Business Day following the Trade Date shall be treated by the Fund or its designee as if received prior to the Close of Trading on the Trade Date. All orders received by the Company after the Close of Trading on a Business Day shall not be aggregated with Orders received by the Company prior to the Close of Trading on such Business Day and shall be communicated to BRIL or its designee as part of an aggregated order no sooner than after the FUND/SERV Transactions Deadline or such other time as may be agreed by the parties from time to time) the following Business Day. Cash settlement shall be transmitted pursuant to the normal NSCC settlement process. In the case of delayed settlement, the Fund or its designee shall make arrangements for the settlement of redemptions by wire no later than the time permitted for settlement of redemption orders by the 1940 Act. Unless otherwise informed in writing, such redemption wires should be sent to an account specified by the Company and agreed to by Fund Parties.
Points of Interconnection and Trunk Types 2.1 Point(s) of Interconnection. 2.1.1 Each Party, at its own expense, shall provide transport facilities to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA selected by PNG.
Goal Setting a. Defining goals b. Personal goals vs. family and societal goals c. Personal history of achieving or not achieving goals d. Components of a well-developed goal e. The relationship between short-, mid-, and long-range goals f. Setting goals g. Barriers to goals
Pricing Information; Orders; Settlement (a) The Fund will make Fund shares available to be purchased by ING Life, and will accept redemption orders from ING Life, on behalf of each Account at the net asset value applicable to each order on those days on which the Fund calculates its net asset value (a "Business Day"). Fund shares shall be purchased and redeemed in such quantity and at such time determined by ING Life to be necessary to meet the requirements of those Contracts for which the Fund(s) serve as underlying investment media, provided, however, that the Board of Trustees of the Fund (hereinafter the "Trustees") may upon reasonable notice to ING Life, refuse to sell shares of any Portfolio to any person, or suspend or terminate the offering of shares of any Portfolio if such action is required by law or by regulatory authorities having jurisdiction or is, in the sole discretion of the Trustees, acting in good faith and in the best interests of the shareholders of any Portfolio and in compliance with their fiduciary obligations under federal and/or any applicable state laws, necessary in the best interests of the shareholders of any Portfolio. (b) The Fund will provide to ING Life closing net asset value, dividend and capital gain information at the close of trading each day that the New York Stock Exchange (the "Exchange") is open (each such day a "Business Day"), and in no event later than 6:30 p.m. Eastern Standard time on such Business Day. ING Life will send via facsimile or electronic transmission to the Fund or its specified agent orders to purchase and/or redeem Fund shares by 9 a.m. Eastern Standard Time the following business day. Payment for net purchases will be wired by ING Life to an account designated by the Fund to coincide with the order for shares of the Fund. (c) The Fund hereby appoints ING Life as its agent for the limited purpose of accepting purchase and redemption orders for Fund shares relating to the Contracts from Contract owners or participants. Orders from Contract owners or participants received from any distributor of the Contracts (including affiliates of ING Life) by ING Life, acting as agent for the Fund, prior to the close of the Exchange on any given business day will be executed by the Fund at the net asset value determined as of the close of the Exchange on such Business Day, provided that the Fund receives written (or facsimile) notice of such order by 9 a.m. Eastern Standard Time on the next following Business Day. Any orders received by ING Life acting as agent on such day but after the close of the Exchange will be executed by the Fund at the net asset value determined as of the close of the Exchange on the next business day following the day of receipt of such order, provided that the Fund receives written (or facsimile) notice of such order by 9 a.m. Eastern Standard Time within two days following the day of receipt of such order. (d) Payments for net redemptions of shares of the Fund will be wired by the Fund to an account designated by ING Life by 4:00 p.m. Eastern Standard Time on the same Business Day ING Life places an order to redeem Fund Shares. Payments for net purchases of the Fund will be wired by ING Life to an account designated by the Fund by 4:00 p.m. Eastern Standard Time on the same Business Day ING Life places an order to purchase Fund shares. Payments shall be in federal funds transmitted by wire. (e) In lieu of applicable provisions set forth in paragraphs 2(a) through 2(d) above, the parties may agree to provide pricing information, execute orders and wire payments for purchases and redemptions through National Securities Clearing Corporation's Fund/SERV system in which case such activities will be governed by the provisions set forth in Exhibit I to this Agreement. (f) Each party has the right to rely on information or confirmations provided by the other party (or by any affiliate of the other party), and shall not be liable in the event that an error is a result of any misinformation supplied by the other party (g) The Fund and Distributor shall indemnify and hold ING Life harmless, from the effective date of this Agreement, against any amount ING Life is required to pay to Contract owners or participants due to: (i) an incorrect calculation of a Fund's daily net asset value, dividend rate, or capital gains distribution rate or (ii) incorrect or late reporting of the daily net asset value, dividend rate, or capital gain distribution rate of a Fund, upon written notification by ING Life, with supporting data, to Distributor. In addition, the Fund or the Distributor shall be liable to ING Life for systems and out of pocket costs incurred by ING Life in making a Contract owner's or a participant's account whole, if such costs or expenses are a result of the Fund's or the Distributor's failure to provide timely or correct net asset values, dividend and capital gains or financial information. If a mistake is caused in supplying such information or confirmations, which results in a reconciliation with incorrect information, the amount required to make a Contract owner's or a participant's account whole shall be borne by the party providing the incorrect information, regardless of when the error is corrected. (h) ING Life agrees to purchase and redeem the shares of the Funds named in Schedule B offered by the then current prospectus and statement of additional information of the Fund in accordance with the provisions of such prospectus and statement of additional information.
Two-Way Interconnection Trunks 2.4.1 Where the Parties use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and Ymax, Ymax, at its own expense, shall: 2.4.1.1 provide its own facilities to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA; and/or 2.4.1.2 obtain transport to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA (a) from a third party, or, (b) if Verizon offers such transport pursuant to this Agreement or an applicable Verizon Tariff, from Verizon. 2.4.2 Where the Parties use Two-Way Interconnection Trunks for the exchange of traffic between Verizon and Ymax, Verizon, at its own expense, shall provide its own facilities to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA. 2.4.3 Prior to establishing any Two-Way Interconnection Trunks, Ymax shall meet with Verizon to conduct a joint planning meeting (“Joint Planning Meeting”). At that Joint Planning Meeting, each Party shall provide to the other Party originating Centium Call Seconds (Hundred Call Seconds) information, and the Parties shall mutually agree on the appropriate initial number of End Office and Tandem Two-Way Interconnection Trunks and the interface specifications at the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA at which the Parties interconnect for the exchange of traffic. Where the Parties have agreed to convert existing One-Way Interconnection Trunks to Two-Way Interconnection Trunks, at the Joint Planning Meeting, the Parties shall also mutually agree on the conversion process and project intervals for conversion of such One- Way Interconnection Trunks to Two-Way Interconnection Trunks. 2.4.4 On a semi-annual basis, Ymax shall submit a good faith forecast to Verizon of the number of End Office and Tandem Two-Way Interconnection Trunks that Ymax anticipates Verizon will need to provide during the ensuing two (2) year period for the exchange of traffic between Ymax and Verizon. Ymax’s trunk forecasts shall conform to the Verizon CLEC trunk forecasting guidelines as in effect at that time. 2.4.5 The Parties shall meet (telephonically or in person) from time to time, as needed, to review data on End Office and Tandem Two-Way Interconnection Trunks to determine the need for new trunk groups and to plan any necessary changes in the number of Two-Way Interconnection Trunks. 2.4.6 Two-Way Interconnection Trunks shall have SS7 Common Channel Signaling. The Parties agree to utilize B8ZS and Extended Super Frame (ESF) DS1 facilities, where available. 2.4.7 With respect to End Office Two-Way Interconnection Trunks, both Parties shall use an economic Centium Call Seconds (Hundred Call Seconds) equal to five (5). Either Party may disconnect End Office Two-Way Interconnection Trunks that, based on reasonable engineering criteria and capacity constraints, are not warranted by the actual traffic volume experienced. 2.4.8 Two-Way Interconnection Trunk groups that connect to a Verizon access Tandem shall be engineered using a design blocking objective of Xxxx-Xxxxxxxxx B.005 during the average time consistent busy hour. Two-Way Interconnection Trunk groups that connect to a Verizon local Tandem shall be engineered using a design blocking objective of Xxxx- Xxxxxxxxx B.01 during the average time consistent busy hour. Verizon and Xxxx shall engineer Two-Way Interconnection Trunks using BOC Notes on the LEC Networks SR-TSV-002275. 2.4.9 The performance standard for final Two-Way Interconnection Trunk groups shall be that no such Interconnection Trunk group will exceed its design blocking objective (B.005 or B.01, as applicable) for three (3) consecutive calendar traffic study months. 2.4.10 Ymax shall determine and order the number of Two-Way Interconnection Trunks that are required to meet the applicable design blocking objective for all traffic carried on each Two-Way Interconnection Trunk group. Ymax shall order Two-Way Interconnection Trunks by submitting ASRs to Verizon setting forth the number of Two-Way Interconnection Trunks to be installed and the requested installation dates within Verizon’s effective standard intervals or negotiated intervals, as appropriate. Ymax shall complete ASRs in accordance with OBF Guidelines as in effect from time to time. 2.4.11 Verizon may (but shall not be obligated to) monitor Two-Way Interconnection Trunk groups using service results for the applicable design blocking objective. If Verizon observes blocking in excess of the applicable design objective on any Tandem Two-Way Interconnection Trunk group and Ymax has not notified Verizon that it has corrected such blocking, Verizon may submit to Ymax a Trunk Group Service Request directing Ymax to remedy the blocking. Upon receipt of a Trunk Group Service Request, Ymax will complete an ASR to establish or augment the End Office Two-Way Interconnection Trunk group(s), or, if mutually agreed, to augment the Tandem Two-Way Interconnection Trunk group with excessive blocking and submit the ASR to Verizon within five (5) Business Days. 2.4.12 The Parties will review all Tandem Two-Way Interconnection Trunk groups that reach a utilization level of seventy percent (70%), or greater, to determine whether those groups should be augmented. Ymax will promptly augment all Tandem Two-Way Interconnection Trunk groups that reach a utilization level of eighty percent (80%) by submitting ASRs for additional trunks sufficient to attain a utilization level of approximately seventy percent (70%), unless the Parties agree that additional trunking is not required. For each Tandem Two-Way Interconnection Trunk group with a utilization level of less than sixty percent (60%), unless the Parties agree otherwise, Ymax will promptly submit ASRs to disconnect a sufficient number of Interconnection Trunks to attain a utilization level of approximately sixty percent (60%) for each respective group, unless the Parties agree that the Two-Way Interconnection Trunks should not be disconnected. In the event Ymax fails to submit an ASR for Two-Way Interconnection Trunks in conformance with this Section, Verizon may disconnect the excess Interconnection Trunks or bill (and Ymax shall pay) for the excess Interconnection Trunks at the applicable Verizon rates. 2.4.13 Because Verizon will not be in control of when and how many Two- Way Interconnection Trunks are established between its network and Ymax’s network, Verizon’s performance in connection with these Two- Way Interconnection Trunk groups shall not be subject to any performance measurements and remedies under this Agreement, and, except as otherwise required by Applicable Law, under any FCC or Commission approved carrier-to-carrier performance assurance guidelines or plan. 2.4.14 Ymax will route its traffic to Verizon over the End Office and Tandem Two-Way Interconnection Trunks in accordance with SR-TAP-000191, including but not limited to those standards requiring that a call from Ymax to a Verizon End Office will first be routed to the End Office Interconnection Trunk group between Ymax and the Verizon End Office.
END USER AGREEMENTS (“EUA GAC acknowledges that the END USER may choose to enter into an End User Agreement (“EUA) with the Contractor through this Agreement, and that the term of the EUA may exceed the term of the current H-GAC Agreement. H-GAC’s acknowledgement is not an endorsement or approval of the End User Agreement’s terms and conditions. Contractor agrees not to offer, agree to or accept from the END USER, any terms or conditions that conflict with those in Contractor’s Agreement with H-GAC. Contractor affirms that termination of its Agreement with H-GAC for any reason shall not result in the termination of any underlying EUA, which shall in each instance, continue pursuant to the EUA’s stated terms and duration. Pursuant to the terms of this Agreement, termination of this Agreement will disallow the Contractor from entering into any new EUA with END USERS. Applicable H-GAC order processing charges will be due and payable to H-GAC