Scheduling of Maintenance to Avoid High Flow Periods Sample Clauses

Scheduling of Maintenance to Avoid High Flow Periods. Chelan PUD began an aggressive program in 2000 to limit the incidence of spill due to maintenance outages during periods of the year and times of day when river flows approach the hydraulic capacity of the powerhouse. The hydraulic capacity of the powerhouse, when all 11 turbines are operating, is 204,000 cfs at the most efficient operating point and 212,000 cfs can be passed without needing to spill. Typically, these flow levels are not reached during river management for power generation. The hydraulic capacity of the powerhouse, when 10 turbines are available, is reduced to either 182,000 cfs or 187,000 cfs, depending on the type of turbine out of service for maintenance. The planning process schedules lengthy maintenance outages to the months in the year when flow releases from Grand Coulee and power demand are typically the lowest, with most turbine overhaul scheduled for March to mid-May or September to mid- November. Short duration outages, such as inspections, trash rack cleaning and smaller repair jobs are either scheduled for nighttime and weekends or, if scheduled during the day, are of a nature that work can be suspended or postponed to avoid spill if river flows approach the hydraulic capacity. Outage planning is focused on the shape of the daily flow pattern. The use of the Hourly Coordination Agreement gives the project operations personnel sufficient advance warning to cancel planned outages and avoid spill if the flow pattern changes to higher levels than predicted.
AutoNDA by SimpleDocs

Related to Scheduling of Maintenance to Avoid High Flow Periods

  • Notifications of Outages and Maintenance In the event that a Registry Operator plans maintenance, it will provide notice to the ICANN emergency operations department, at least, twenty-­‐four (24) hours ahead of that maintenance. ICANN’s emergency operations department will note planned maintenance times, and suspend Emergency Escalation services for the monitored services during the expected maintenance outage period. If Registry Operator declares an outage, as per its contractual obligations with ICANN, on services under a service level agreement and performance requirements, it will notify the ICANN emergency operations department. During that declared outage, ICANN’s emergency operations department will note and suspend emergency escalation services for the monitored services involved.

  • INTERIM MAINTENANCE PERIOD During the interim maintenance period between obtaining of the completion certificate of Project and formation and operationalization of the Association the Promoter shall through itself or through a facility management company constitute a committee to run, operate, manage and maintain the Common Areas.

  • Maintenance Scheduling The NTO shall schedule maintenance of its facilities designated as NTO Transmission Facilities Under ISO Operational Control and schedule any outages (other than forced transmission outages) of said transmission system facilities in accordance with outage schedules approved by the ISO. The NTO shall comply with maintenance schedules coordinated by the ISO, pursuant to this Agreement, for NTO Transmission Facilities Under ISO Operational Control. The NTO shall be responsible for providing notification of maintenance schedules to the ISO for NTO Transmission Facilities Requiring ISO Notification. The NTO shall provide notification of maintenance schedules to affected Transmission Owners for NTO Transmission Facilities Requiring ISO Notification and Local Area Transmission Facilities pursuant to Section 3.5.3 of the ISO Services Tariff.

  • SYSTEM CHANGES AND MAINTENANCE/SUPPORT The Contractor shall give a minimum of 5 business days advance Written notice to the designated Authorized User contact of any upgrades, system changes and Maintenance/support actions that may potentially impact services described in the Authorized User Agreement. Upgrades, system changes, and Maintenance/support actions which are required by system vulnerabilities or emergency situations shall be carried out by the Contractor to protect the system. Authorized Users shall be notified by the Contractor as soon as possible after the change has taken place. Contractor shall provide documentation of upgrades, system changes and Maintenance/support actions upon request from an Authorized User. EXPIRATION, TERMINATION OR SUSPENSION OF SERVICES Return of Data The Contractor shall return Data in a format agreed upon within the Authorized User Agreement or as agreed to with the Authorized User. This can, if specified within the Authorized User Agreement, be carried out by providing application programmable interface or other such efficient electronic tools. The Contractor must certify all Data has been removed from its system and removed from backups within timeframes established in the Authorized User Agreement or as agreed to with the Authorized User. Suspension of Services During any period of suspension of service, the Authorized User shall have full access to all Data at no charge. This can, if specified within the Authorized User Agreement, be carried out by providing an application programmable interface or other such efficient electronic tools. The Contractor shall not take any action to erase and/or withhold any Authorized User Data, except as directed by the Authorized User. Expiration or Termination of Services Upon expiration or termination of an Authorized User Agreement, the Authorized User shall have full access to all Data for a period of 60 calendar days. Unless noted in the original Authorized User Agreement, this period will be covered at no charge. This can, if specified within the Authorized User Agreement, be carried out by providing application programmable interface or other such efficient electronic tools. During this period, the Contractor shall not take any action to erase and/or withhold any Data, except as directed by the Authorized User. An Authorized User shall have the right to specify a period in excess of 60 calendar days in its RFQ. SECURE DATA DISPOSAL When requested by the Authorized User, the Contractor shall destroy Data in all of its forms, including all back-ups. Data shall be permanently deleted and shall not be recoverable, according ITS Policy S13-003 Sanitization/Secure Disposal or successor and S14-003 Information Security Controls or successor. Certificates of destruction, in a form acceptable to the Authorized User, shall be provided by the Contractor to the Authorized User.

  • Scheduling of Overtime In any case where no employee is available to work a shift or the extension of a shift at straight time, and the Employer thereupon determines that it is necessary to assign the work on an overtime basis, the following provisions will govern the assignment of the overtime.

  • Outages and Maintenance In the event that a Registry Operator plans maintenance, it will provide notice to the ICANN emergency operations department, at least, twenty-four (24) hours ahead of that maintenance. ICANN’s emergency operations department will note planned maintenance times, and suspend Emergency Escalation services for the monitored services during the expected maintenance outage period. If Registry Operator declares an outage, as per its contractual obligations with ICANN, on services under a service level agreement and performance requirements, it will notify the ICANN emergency operations department. During that declared outage, ICANN’s emergency operations department will note and suspend emergency escalation services for the monitored services involved.

  • MONITORING OF OPERATION AND MAINTENANCE 19.1 Monthly status reports During Operation Period, the Concessionaire shall, no later than 7 (seven) days after the close of each month, furnish to the Authority and the Independent Engineer a monthly report stating in reasonable detail the condition of the Bus Terminal including its compliance or otherwise with the Maintenance Requirements, Maintenance Manual, Maintenance Programme and Safety Requirements, and shall promptly give such other relevant information as may be required by the Independent Engineer. In particular, such report shall separately identify and state in reasonable detail the defects and deficiencies that require rectification.

  • Maintenance Period During the Maintenance Period the Developer shall at its own expense maintain repair and otherwise S.9 keep the Works in good working order and repair to the reasonable satisfaction of xxx Xxxxxxxxxx unless xxx Xxxxxxxxxx shall declare that any required maintenance and/or repair is an emergency in which case the Developer shall carry out the said maintenance and/or repair immediately Access to the Works and consequences of inspections The Developer shall arrange for xxx Xxxxxxxxxx to have access to the Works and the Site at all

  • Maintenance Outages If Seller reasonably determines that it is necessary to schedule a Maintenance Outage, Seller shall notify Buyer of the proposed Maintenance Outage at least five (5) days before the outage begins (or such shorter period to which Buyer may reasonably consent in light of then existing conditions). Upon such notice, the Parties shall plan the Maintenance Outage to mutually accommodate the reasonable requirements of Seller and the service obligations of Buyer; provided, however, that, unless Buyer otherwise consents, such consent not to be unreasonably withheld, no Maintenance Outage may be scheduled between the hour ending 0700 through the hour ending 2200, Monday through Saturday, during the time period commencing on May 15 and concluding on September 15. Notice of a proposed Maintenance Outage shall include the expected start date and time of the outage, the amount of Capacity of the Facility that will not be available, and the expected completion date and time of the outage. Seller shall give Buyer notice of the Maintenance Outage as soon as Seller determines that the Maintenance Outage is necessary. Buyer shall promptly respond to such notice and may request reasonable modifications in the schedule for the outage. Seller shall use all reasonable efforts to comply with any request to modify the schedule for a Maintenance Outage. Seller shall notify Buyer of any subsequent changes in Capacity available to Buyer or any changes in the Maintenance Outage completion date and time. As soon as practicable, any notifications given orally shall be confirmed in writing. Seller shall take all reasonable measures and exercise its best efforts in accordance with Prudent Electrical Practices to minimize the frequency and duration of Maintenance Outages.

  • Penalties for Non-compliance to Service Level Agreement Where the Supplier/Service Provider fails to deliver the Goods/Services within the agreed and accepted milestone timelines and provided that the cause of the delay was not due to a fault of Transnet, penalties shall be imposed at …………………………………………………… .

Time is Money Join Law Insider Premium to draft better contracts faster.