Slab on Grade. The slab-on-grade shall be a minimum of 4" thick, 3,000 psi concrete, with welded wire fabric reinforcing, supported on a 4" aggregate base course. Sawcut control joints at spacing intervals recommended by the structural engineer. Slabs shall be constructed with a flatness tolerance of 1/4" in 10' radius.
AutoNDA by SimpleDocs
Slab on Grade. Xxxxx agrees that all buildings constructed on the Property shall be constructed slab on grade and shall have no living, working, storage or parking areas below grade. Notwithstanding the foregoing, below-grade utilities and foundations are permitted, provided that Buyer protects them from vapor or liquid intrusion by installing an appropriate vapor/liquid barrier and vapor ventilation system, if required.
Slab on Grade a. Subgrade and sub base preparation and maintenance for all slab-on-grade concrete installations x. Xxxxx sub base installation and compaction for all slab-on-grade concrete installations. c. Furnishing and installing all concrete materials and accessories for all slab-on-grade concrete installations to include concrete materials, aggregates, vapor barrier, reinforcing materials, curing compounds and admixtures. d. Placing and finishing of all concrete materials for slab-on-grade installations, including formwork, concrete pumping, saw cutting, application of curing compounds and/or sealers and concrete finishing.
Slab on Grade. A. Slab on grade to be 5" unreinforced slab on grade utilizing 5-1/2 sack, fG = 3000 psi concrete with 4" maximum slump Control joints per A.C.I. See structural drawings.
Slab on Grade. (1) Five inch (5") thick 3,000 PSI concrete reinforced with synthetic fibers. The surface will be steel trowel finished and floors will be chemically cured and hardened with "Lapidolith". Subgrade will be chemically treated for termite protection. Caulking of floor joints is excluded. (2) Column isolation joint will be non-keyed, diamond or round formed with asphalt impregnated felt. (3) Expansion joints at slab perimeter with asphalt impregnated fiberboard, 5/8" thick. (4) Control joints saw cut, 1/4 of slab depth, 1/8" wide, bisect bays. (5) Construction joints will have smooth dowels every 18" on center. Exhibit C Custom Chrome, Inc. Xxxxxxxx Xxxxxxxxxx Xxxx - Xxxxxxxx Xx. 0 February 11, 1997 Page Three
Slab on Grade thick; 3,000 psi concrete with 8 mil. vapor barrier on compacted earth.
Slab on Grade. Minimum of 5" thick, reinforced with reinforcing bars (not welded wire mesh) over a membrane vapor barrier and above a compacted aggregate base.
AutoNDA by SimpleDocs
Slab on Grade. Grantee agrees that all buildings constructed on the Property must be constructed slab on grade and must not have any living, working, storage or parking areas below grade.
Slab on Grade. Perimeter insulation will be 2” polystyrene, 2 feet down and 2 feet in, foamular 250 - 4” stone base will be #6 stone covered with a 6 mil polyethylene vapor barrier -A 4”, 3,000 PSI concrete slab will be provided and receive 1 coat of curing compound to be coordinated with tenant.
Slab on Grade. 1.1.3 Building standard heating, ventilating and air conditioning in its "AS-IS" condition) and air-conditioning service ["HVAC"]).