SPREAD FOOTINGS Sample Clauses

SPREAD FOOTINGS. Spread footings placed on undisturbed glacial till or prepared structural fill placed on glacial till would be suitable for the foundations of the abutments. Based on the results of the present investigation the excavations could extend upwards of 2.0 m below the water level. Temporary cofferdams or other seepage barriers will likely be required for construction. Base preparation for spread footings should consist of removal of all asphalt, fill, loose sands and any other deleterious materials (peat, organics, etc.) down to native undisturbed glacial till. Structural fill, if required, should consist of well graded granular material (granular Class C, or similar) or well graded rockfill, placed in lifts and compacted to 100 percent standard Xxxxxxx maximum dry density (SPMDD) Excavations within the existing fills and underlying silty sands should be no steeper than 1 horizontal to 1 vertical without means of shoring. Slopes that extend below the water table will likely require further flattening or the use of a blanket of well graded rockfill to provide stability from sloughing. Groundwater should be kept to a minimum in the footing excavations to prevent disturbance of the glacial till which is susceptible to softening. Dewatering could be accomplished by pumping from the base of excavation, filtered sumps or well-points installed below the base of excavation. It is recommended that the final excavation for footings placed on undisturbed glacial till be carried out with a ditching bucket so as to minimize disturbance of the bearing surface. Any soil that becomes disturbed as a result of construction activity or softened due to water infiltration should be removed from the bearing surface prior to footing placement. If softening persists, consideration could be given to the over-excavation of the bearing surface to allow for the placement of a mudslab or clean gravel layer. Spread footings placed on undisturbed glacial till or structural fill may be designed using a bearing resistance at Ultimate Limit States (ULS) of 250 kPa provided they are a minimum of
AutoNDA by SimpleDocs
SPREAD FOOTINGS i. Provide at column line intersections, sized by registered structural engineer designs.

Related to SPREAD FOOTINGS

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.

  • ADJACENT EXCAVATION-SHORING 32. If an excavation shall be made upon land adjacent to the demised premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the demised premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which demised premises form a part from injury or damage and to support the same by proper foundations without any claim for damages or indemnity against Owner, or diminution or abatement of rent.

  • Underground Tanks If underground or other storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any underground storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks.

  • Elevators Landlord shall provide passenger elevator service during normal business hours to Tenant in common with Landlord and all other tenants. Landlord shall provide limited passenger service at other times, except in case of an emergency.

  • Underground Storage Tanks In accordance with the requirements of Section 3(g) of the D.C. Underground Storage Tank Management Act of 1990, as amended by the District of Columbia Underground Storage Tank Management Act of 1990 Amendment Act of 1992 (D.C. Code § 8-113.01, et seq.) (collectively, the “UST Act”) and the applicable D.C. Underground Storage Tank Regulations, 20 DCMR Chapter 56 (the “UST Regulations”), District hereby informs the Developer that it has no knowledge of the existence or removal during its ownership of the Property of any “underground storage tanks” (as defined in the UST Act). Information pertaining to underground storage tanks and underground storage tank removals of which the D.C. Government has received notification is on file with the District Department of the Environment, Underground Storage Tank Branch, 00 X Xxxxxx, X.X., Xxxxx Xxxxx, Xxxxxxxxxx, X.X., 00000, telephone (000) 000-0000. District’s knowledge for purposes of this Section shall mean and be limited to the actual knowledge of Xxxxxx Xxxxx, Property Acquisition and Disposition Division of the Department of Housing and Community Development, telephone no. (000) 000-0000. The foregoing is set forth pursuant to requirements contained in the UST Act and UST Regulations and does not constitute a representation or warranty by District.

  • Storage Tanks If storage tanks storing Hazardous Materials located on the Premises or the Project are used by Tenant or are hereafter placed on the Premises or the Project by Tenant, Tenant shall install, use, monitor, operate, maintain, upgrade and manage such storage tanks, maintain appropriate records, obtain and maintain appropriate insurance, implement reporting procedures, properly close any storage tanks, and take or cause to be taken all other actions necessary or required under applicable state and federal Legal Requirements, as such now exists or may hereafter be adopted or amended in connection with the installation, use, maintenance, management, operation, upgrading and closure of such storage tanks. Notwithstanding anything to the contrary contained herein, Tenant shall have no right to use or install any underground storage tanks at the Project.

  • Floor Loading Floor loading capacity shall be within building design capacity. Tenant may exceed floor loading capacity with Landlord’s consent, at Landlord’s sole discretion and must, at Tenant’s sole cost and expense, reinforce the floor as required for such excess loading.

  • Parking Throughout the Lease Term, Tenant shall have the exclusive right to use, free of charges, the number of parking spaces set forth in Section 12 of the Summary, which parking spaces constitute the entirety of the parking under the Building and the adjacent surface parking, being all of the parking in the Project. Tenant shall comply with the Parking Rules and Regulations which are in effect on the date hereof, as set forth in the attached Exhibit D and all reasonable modifications and additions thereto which are prescribed from time to time for the orderly operation and use of the Parking Areas by Landlord, and/or Landlord’s Parking Operator (as defined below); provided that such modifications or alterations do not effect Tenant’s use of or access to the Parking Areas. Landlord specifically reserve the right to change the size, configuration, design, layout, of the Parking Areas, and Tenant acknowledges and agrees that Landlord may, without incurring any liability to Tenant and without any abatement of Rent under this Lease, from time to time, temporarily close-off or restrict access to the Parking Areas, so long as Tenant retains access to the number of parking spaces set forth in Section 12 of the Summary. Landlord may delegate its responsibilities hereunder to a parking operator (the “Parking Operator”) in which case the Parking Operator shall have all the rights of control attributed hereby to Landlord. Any parking tax or other charges imposed by governmental authorities in connection with the use of such parking shall be paid directly by Tenant or the parking users, or, if directly imposed against Landlord, Tenant shall reimburse Landlord for all such taxes and/or charges within thirty (30) days after Landlord’s demand therefor. The parking rights provided to Tenant pursuant to this Article 23 are provided solely for use by Tenant’s own personnel visitors and invitees and such rights may not be transferred, assigned, subleased or otherwise alienated by Tenant without Landlord’s prior approval, except in connection with an assignment of this Lease or sublease of the Premises made in accordance with Article 14 above.

  • Roof Any leaks or evidence of moisture? Yes No Unknown Type of Roof: Age Comments: Is there any existing fire retardant treated plywood? Yes No Unknown Comments:

  • Interior (a) Ceilings, sidewalls and bulkhead panels shall be clean and free of cracks and stains;

Time is Money Join Law Insider Premium to draft better contracts faster.