STANDARD INTERIOR OFFICE ACOUSTICAL PARTITION. a. Provide 2-1/2"-25 gage metal studs at 16" O.C. at walls (or as otherwise noted) per details illustrated on drawings. b. 5/8" standard gypsum board, one layer each side, attached to studs with screws as required by code and as recommended by the Gypsum Association. c. Partition height shall extend from floor slab to underside of metal or roof deck above (+13'-6" AFF, nominal). Refer to wall types and referenced details illustrated on drawings. d. Partitions terminating at curtainwall and/or storefront framing systems shall receive a continuous neoprene sound gasket between the mullion and the metal wall trim cap. e. Provide continuous bead of acoustical sealant between bottom edge of gypsum board panels and floor slab. Cut gypsum board panels at top of wall to fit undulations of metal deck structures and seal all gaps with drywall taping compound. f. Install R-8 unfaced fiberglass sound xxxxx in cavity between studs, full height of partition. SCHEDULE 2 -2- PEREGRINE SYSTEMS CORPORATE CENTER [Peregrine Systems] TENANT IMPROVEMENT STANDARD SPECIFICATIONS XXXXXX XXXXXX CENTER -------------------------------------------------------------------------------- CARRIER XXXXXXX PROJECT NO. 4246.00 MAY 4, 1999 (DRAFT)