SURFACE FINISHING Sample Clauses

SURFACE FINISHING. Surface finishing shall have a semi-gloss sheen, and shall be one of the following Federal Standard 595B colors: Green # 14036, Brown # 10049, Black # 27038, Grey # 26147 or as selected by the EIU. 4.46.1 PAINT All painted posts and/or painted surfaces shall be cleaned of all foreign matter, such as loose paint, rust, dirt, and grease before painting. Paint used must be of the anti-graffiti, corrosion resisting, non-conductive, semi-gloss type as manufactured by Armor Products, Inc., by BC Products International, Inc., by ConLux Coatings, Inc. or an NYCDOT approved equal.
AutoNDA by SimpleDocs
SURFACE FINISHING. 4.43.1. PAINT
SURFACE FINISHING. Surface finishing shall have a semi-gloss sheen, and shall be one of the following Federal Standard 595B colors: Green #14036, Brown #10049, Black #27038, Grey #26147 or as selected by the Engineer. 4.2.42.1. PAINT- All painted posts and/or painted surfaces shall be cleaned of all foreign matter, such as loose paint, rust, dirt, and grease before painting. Paint used must be of the anti-graffiti, corrosion resisting, non-conductive, semi-gloss type as manufactured by Armor Products, Inc., by BC Products International, Inc., by Con- Lux Coatings, Inc. or an approved equal. 4.2.42.1.1. Paint Characteristics: - The protective coating must exhibit the following characteristic. Exceptional resistance to ultra violet light, road salt compounds, and industrial chemical fumes. High impact resistance forward and reverse to withstand 160 psi directly without cracking, chipping, or peeling. Display a water transmission rate of less than 0.00000005 Perms. Bend over 180 degrees and 1/8" mandrel without cracking. Suitable for applications in below freezing temperatures. Resist solvents for removal of graffiti off painted surface. Resist flame or high temperatures to 400 degrees Fahrenheit. Shall possess unique molecular structure suitable for brush, roll or spray application to achieve high quality, general purpose usage, exceptional spreadability and adhesion. Exhibit corrosion resistance equal to that tested as part of Painting System #41 by the Steel Structures Painting Council.
SURFACE FINISHING. Surface finishing shall have a semi-gloss sheen, and shall be one of the following Federal Standard 595B colors: Green #14036, Brown #10049, Black #27038, Grey #26147 or as selected by the Engineer. 4.2.42.1. PAINT- All painted posts and/or painted surfaces shall be cleaned of all foreign matter, such as loose paint, rust, dirt, and grease before painting. Paint used must be of the anti-graffiti, corrosion resisting, non-conductive, semi-gloss type as manufactured by Armor Products, Inc., by BC Products International, Inc., by Con- Lux Coatings, Inc. or an approved equal. 4.2.42.1.1. Paint Characteristics: - The protective coating must exhibit the following characteristic. Exceptional resistance to ultra violet light, road salt compounds, and industrial chemical fumes. High impact resistance forward and reverse to withstand 160 psi directly without cracking, chipping, or peeling. Display a water transmission rate of less than 0.00000005 Perms. Bend over 180 degrees and 1/8" mandrel without cracking. Suitable for applications in below freezing temperatures. Resist solvents for removal of graffiti off painted surface. Resist flame or high temperatures to 400 degrees Fahrenheit. Shall possess unique molecular structure suitable for brush, roll or spray application to achieve high quality, general purpose usage, exceptional spreadability and adhesion. Exhibit corrosion resistance equal to that tested as part of Painting System #41 by the Steel Structures Painting Council. 4.2.42.1.2. Chemical Composition of Paint - All paint must conform with the following chemical requirements: No more than 20 percent Oxal Hexel, 17 percent Butyl Acetate, 3 percent Xylol. Maximum of 40 percent volatile by volume. Minimum of 60 degrees Fahrenheit Flashpoint. Formulated with air-out additives for flowability. Two part aliphatic urethane with a 3 to 1 mixture ration and an absolute minimum of 60 percent solid content. Maximum VOC of 3.45 per gallon. 4.2.42.2. ELECTRICAL CHARACTERISTICS (page GS-9 after the “Chemical Composition of Paint”) Resistance Greater than 20 MegaOhms Leakage Current less than (1) MicroAmp/Square inch at 120 VAC, 60Hz.
SURFACE FINISHING 

Related to SURFACE FINISHING

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins. (2) Maintain waterbars, drainage dips, and other water diversion measures. (3) During active use, patrol and maintain functional drainage. (4) Repair damaged culvert ends.

  • Fabrication Making up data or results and recording or reporting them.

  • Walls 12 Developer shall provide rustication patterns on all walls, except drainage headwalls, in Aesthetic 13 Area 3 in accordance with Exhibit L2.24 of the LAADCR. The final designs shall resemble these 14 simulations.

  • Excavation If an excavation shall be made upon land adjacent to the Leased Premises, or shall be authorized to be made, Tenant shall afford to the person causing or authorized to cause such excavation, license to enter upon the Leased Premises for the purpose of doing such work as said person shall deem necessary to preserve the wall or the building of which the Leased Premises form a part from injury or damage and to support the same by proper foundation, without any claim for damages or indemnity from Landlord, or diminution or abatement of Rent.

  • Interior The insurance covers personal property normally contained in the vehicle and belonging to the owner of the vehicle or a member of his or her household. The insurance covers loss of, and damage to, the property if the damage occurs in connection with: - a compensable fire, theft, or vehicle damage - a sudden and unforeseen external event - theft by the renter - damage in connection with a traffic accident. The insurance does not apply to: - theft-prone property - cash and valuables - property belonging to the renter. - Personal movables must be kept locked in the vehicle. If the requirements are not met, the compensation may be reduced, or the deductible increased. See section

  • Welding Welding and use of cutting torches or cutoff saws will be permitted only in areas that have been cleared or are free of all material capable of carrying fire. Flammable debris and vegetation must be removed from within a minimum 10-foot radius of all welding and cutting operations. A shovel and a 5-gallon standard backpack water container filled and with handpump attached shall be immediately available for use in the event of a fire start. C8.64 – DEBARMENT AND SUSPENSION CERTIFICATION (3/18). Pursuant to 2 CFR 180 and 2 CFR 417, Purchaser shall certify and obtain certifications from its Subcontractors regarding debarment, suspension, ineligibility, and voluntary exclusion, including additional Subcontractors obtained after award of this contract. “Subcontractors” are participants in lower tier covered transactions. Purchaser may rely upon a certification of a prospective Subcontractor that it is not proposed for debarment under 48 CFR 9.4, debarred, suspended, ineligible, or voluntarily excluded from participating in covered transactions or timber sales, unless Purchaser knows that the certification is erroneous. Purchaser shall keep the certifications of its Subcontractors on file until timber sale Termination Date and any extensions thereof, and will provide a copy at the written request of Contracting Officer. Nothing contained in the foregoing shall be construed to require establishment of a system of records in order to render in good faith the certification required by this Subsection. The knowledge and information of Purchaser is not required to exceed that which is normally possessed by a prudent person in the ordinary course of business dealings. If Purchaser knowingly enters into a timber sale transaction with a person who is proposed for debarment under 48 CFR 9.4, suspended, debarred, ineligible, or voluntarily excluded from participation in covered transactions or timber sales, in addition to other remedies available to the Government, Forest Service may pursue available remedies, including suspension and/or debarment. Contracting Officer shall provide a copy of Forms AD-1047 Certification Regarding Debarment, Suspension and Other Responsibility Matters – Primary Covered Transactions and AD-1048 Certification Regarding Debarment, Suspension, Ineligibility and Voluntary Exclusion – Lower Tier Covered Transactions to the Purchaser. Purchaser shall complete form AD-1047 and provide to the Contracting Officer upon request. Purchaser shall require each subcontractor to complete form AD-1048 and provide to the Contracting Officer upon request.

  • Structures Airport facilities such as bridges; culverts; catch basins, inlets, retaining walls, cribbing; storm and sanitary sewer lines; water lines; underdrains; electrical ducts, manholes, handholes, lighting fixtures and bases; transformers; flexible and rigid pavements; navigational aids; buildings; vaults; and, other manmade features of the airport that may be encountered in the work and not otherwise classified herein. 10-50 SUBGRADE. The soil which forms the pavement foundation.

  • Fittings 2.2.1 Support structure and attachment fittings for the flap structure 2.2.2 Support structure and attachment fitting for the engine pylons 2.2.3 Support structure and attachment fitting for the main landing gear 2.2.4 Support structure and attachment fitting for the center wing box

  • Cleaning 8.1 CONTRACTOR shall, at his own expenses, at all times keep the premises free from accumulation of debris, waste materials, and rubbish, and at the completion of the work, he shall remove his tools and equipment and all surplus materials, debris, waste material, and rubbish and shall leave the premises in a neat and clean condition. If CONTRACTOR does not attend to such cleaning immediately upon request, OWNER shall have the right to have this work done by others and deduct the cost therefore from the payment due CONTRACTOR hereunder.

  • Installations Any special carpentry, wiring, electrical or other work, gas, steam, water and drainage connection shall be installed at Exhibitor’s expense, and in accordance with the building and Management’s direction.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!