Project Steering Committee 1. For a sound implementation and management of the project, a steering committee shall be set up in line with provisions of the programme manual. 2. The steering committee is the decision-making body of the project and it shall be composed by representatives of the LP and all PPs duly authorised to represent the respective LP and PP institutions. It shall be chaired by the LP and it shall meet on a regular basis. Associated partners shall be invited to take part in the steering committee in an advisory capacity. External key stakeholders may also be invited to take part to one or more meetings in an observer/advisory capacity. 3. The steering committee shall at least: a. be responsible for monitoring and validating the implementation of the project and the achievement of the planned results as in the approved application form; b. perform the financial monitoring of the project implementation and to decide on any budget modifications as in § 11 of this agreement; c. monitor and manage deviations of the project implementation; d. decide on project modifications (e.g. partnership, budget, activities, and duration) if needed; e. be responsible for the settlement of any disputes within the partnership (as stipulated in § 22 of this agreement). 4. Further aspects, including the creation of sub-groups or task forces, may be set out in the rules of procedure of the steering committee.
Project Coordinator Within 14 days of the effective date of this Consent Agreement, DTSC and Respondent shall each designate a Project Coordinator and shall notify each other in writing of the Project Coordinator selected. Each Project Coordinator shall be responsible for overseeing the implementation of this Consent Agreement and for designating a person to act in his/her absence. All communications between Respondent and DTSC, and all documents, report approvals, and other correspondence concerning the activities performed pursuant to this Consent Agreement shall be directed through the Project Coordinators. Each party may change its Project Coordinator with at least seven days prior written notice.
Project Management Plan 3.2.1 Developer is responsible for all quality assurance and quality control activities necessary to manage the Work, including the Utility Adjustment Work. Developer shall undertake all aspects of quality assurance and quality control for the Project and Work in accordance with the approved Project Management Plan, Good Industry Practice and applicable Law. 3.2.2 Developer shall develop the Project Management Plan and its component parts, plans and other documentation in accordance with the requirements set forth in Section 1.5.2.5
Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.
JOINT LABOUR MANAGEMENT COMMITTEE A Joint Labour Management Committee shall be established to attend to those matters which are of mutual interest. To ensure its effectiveness the Committee shall be separate and apart from the grievance procedure.
Training Committee The parties to this Agreement may form a Training Committee. The Training Committee will be constituted by equal numbers of Employer nominees and ETU employee representatives and have a charter which clearly states its role and responsibilities. It shall monitor the clauses of this Agreement which relate to training and ensure all employees have equal access to training.
Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.
DEVELOPMENT OR ASSISTANCE IN DEVELOPMENT OF SPECIFICATIONS REQUIREMENTS/ STATEMENTS OF WORK
Coordinator 6.4.1 The Coordinator shall be the intermediary between the Parties and the Funding Authority and shall perform all tasks assigned to it as described in the Grant Agreement and in this Consortium Agreement. 6.4.2 In particular, the Coordinator shall be responsible for: - monitoring compliance by the Parties with their obligations - keeping the address list of Members and other contact persons updated and available - collecting, reviewing and submitting information on the progress of the Project and reports and other deliverables (including financial statements and related certification) to the Funding Authority - preparing the meetings, proposing decisions and preparing the agenda of General Assembly meetings, chairing the meetings, preparing the minutes of the meetings and monitoring the implementation of decisions taken at meetings - transmitting promptly documents and information connected with the Project,, - administering the financial contribution of the Funding Authority and fulfilling the financial tasks described in Section 7.3 - providing, upon request, the Parties with official copies or originals of documents which are in the sole possession of the Coordinator when such copies or originals are necessary for the Parties to present claims. If one or more of the Parties is late in submission of any project deliverable, the Coordinator may nevertheless submit the other parties’ project deliverables and all other documents required by the Grant Agreement to the Funding Authority in time. 6.4.3 If the Coordinator fails in its coordination tasks, the General Assembly may propose to the Funding Authority to change the Coordinator. 6.4.4 The Coordinator shall not be entitled to act or to make legally binding declarations on behalf of any other Party or of the consortium, unless explicitly stated otherwise in the Grant Agreement or this Consortium Agreement. 6.4.5 The Coordinator shall not enlarge its role beyond the tasks specified in this Consortium Agreement and in the Grant Agreement. [Option: 6.5 Management Support Team (Optional, where foreseen in Grant Agreement or otherwise decided by the consortium) The Management Support Team shall be proposed by the Coordinator. It shall be appointed by the General Assembly and shall assist and facilitate the work of the General Assembly. The Management Support Team shall provide assistance to the Coordinator for executing the decisions of the General Assembly. It shall be responsible for the day-to-day management of the Project.] [Option: 6.6 External Expert Advisory Board (EEAB) (Optional, where foreseen in Grant Agreement or otherwise decided by the consortium) An External Expert Advisory Board (EEAB) will be appointed and steered by the Executive Board. The EEAB shall assist and facilitate the decisions made by the General Assembly. The Coordinator is authorised to execute with each member of the EEAB a non-disclosure agreement, which terms shall be not less stringent than those stipulated in this Consortium Agreement, no later than 30 days after their nomination or before any confidential information will be exchanged, whichever date is earlier. The Coordinator shall write the minutes of the EEAB meetings and prepare the implementation of the EEAB's suggestions. The EEAB members shall be allowed to participate in General Assembly meetings upon invitation but have not any voting rights.]
Statewide HUB Program Statewide Procurement Division Note: In order for State agencies and institutions of higher education (universities) to be credited for utilizing this business as a HUB, they must award payment under the Certificate/VID Number identified above. Agencies, universities and prime contractors are encouraged to verify the company’s HUB certification prior to issuing a notice of award by accessing the Internet (xxxxx://xxxxx.xxx.xxxxx.xx.xx/tpasscmblsearch/index.jsp) or by contacting