Utilization Set Sample Clauses

Utilization Set. Off (Reliability) If the Reliability Ratei as calculated in section 4.2.2 above for any Interval “i” in an Activation Hour is less than 85%, then a Utilization Set-Off (Reliability) shall be calculated as the sum of the Utilization Set-Off (Reliability) for each such Activation Hour in the Activation Period, as follows: Utilization Set-Off (Reliability) = ∑AH =AP (Performance Set-Off Factor x (Utilization Rate/hour) AH =1 x Monthly Contracted MW) Utilization Rate ($/MWh) Means the rate defined in Exhibit A – Definitions.
AutoNDA by SimpleDocs
Utilization Set. Off (Timely Confirmation) If the Participant, regardless of Activation, fails to deliver, or delivers late, one or more required Confirmations in the Contract Month, then a Utilization Set-Off (Timely Confirmation) shall be calculated as the sum of the Utilization Set-Off (Timely Confirmation) for each such Contracted Dispatch Period over the Contract Month, as follows: Utilization Set-Off (Timely Confirmation) = ∑CDP=CDM (Performance Set-Off Factor x Utilization Rate x CDP=1 Monthly Contracted MW)

Related to Utilization Set

  • Utilization Scale STATE shall scale logs or portions of logs that are broken, wasted, or not removed by PURCHASER due to: (1) improper felling or bucking of the logs; (2) failure to remove the logs prior to deterioration; and (3) logs remaining on the timber sale area after completion of logging, provided the logs were merchantable prior to breakage or wastage. Material used to meet down material requirements in the section titled, "Reserved Timber," shall not be considered for utilization scale. PURCHASER shall pay for the logs at the contract price designated in Section 44. STATE shall notify PURCHASER of the volume of logs so scaled. Payment shall be considered due on such volume as if the logs were removed on the date of said notification. In the event PURCHASER disagrees with the findings made by STATE under this section, PURCHASER may furnish scaling by a third-party scaling organization acceptable to STATE. Costs and expenses of such third party shall be paid for by PURCHASER, and the findings of the third party shall be final.

  • Utilization Utilization shall be defined as Trunks Required as a percentage of Trunks In Service.

  • System Availability System Availability percentage is calculated as follows:  Total MinutesintheMonth −Downtime   System Availability%age =  Total MinutesintheMonth *100    System Availability SLA (“SLA”) 99.5% System Availability percentage during each Month for productive versions Credit 2% of Monthly Subscription Fees for each 1% below SLA, not to exceed 100% of Monthly Subscription Fees Excluded Downtime Total Minutes in the Month attributable to: (i) a Scheduled Downtime for which a Regular Maintenance Window is described in Section 4 below, or (ii) any other Scheduled Downtime according to Section 4 for which the customer has been notified at least five (5) business days prior to such Scheduled Downtime or (iii) unavailability caused by factors outside of SAP’s reasonable control, such as unpredictable and unforeseeable events that could not have been avoided even if reasonable care had been exercised. Scheduled Downtime Scheduled Downtime for the applicable Cloud Services to which customer has subscribed is set forth in Section 4 below entitled “Maintenance Windows for Cloud Services”.

  • Service Availability You understand that Service availability is at all times conditioned upon the corresponding operation and availability of the communication systems used in communicating your instructions and requests to the Credit Union. We will not be liable or have any responsibility of any kind for any loss or damage thereby incurred by you in the event of any failure or interruption of such communication systems or services resulting from the act or omission of any third party, or from any other cause not reasonably within the control of the Credit Union.

  • Utilization Review We review health services to determine whether the services are or were Medically Necessary or experimental or investigational ("Medically Necessary"). This process is called Utilization Review. Utilization Review includes all review activities, whether they take place prior to the service being performed (Preauthorization); when the service is being performed (concurrent); or after the service is performed (retrospective). If You have any questions about the Utilization Review process, please call the number on Your ID card. The toll-free telephone number is available at least 40 hours a week with an after-hours answering machine. All determinations that services are not Medically Necessary will be made by: 1) licensed Physicians; or 2) licensed, certified, registered or credentialed health care professionals who are in the same profession and same or similar specialty as the Provider who typically manages Your medical condition or disease or provides the health care service under review. We do not compensate or provide financial incentives to Our employees or reviewers for determining that services are not Medically Necessary. We have developed guidelines and protocols to assist Us in this process. Specific guidelines and protocols are available for Your review upon request. For more information, call the number on Your ID card or visit Our website at xxx.xxxxxxx.xxx.

  • Reallocation to a Class with a Lower Salary Range Maximum 1. If the employee meets the skills and abilities requirements of the position and chooses to remain in the reallocated position, the employee retains existing appointment status and has the right to be placed on the Employer’s internal layoff list for the classification occupied prior to the reallocation.

  • Under-Frequency and Over Frequency Conditions The New York State Transmission System is designed to automatically activate a load- shed program as required by the NPCC in the event of an under-frequency system disturbance. Developer shall implement under-frequency and over-frequency relay set points for the Large Generating Facility as required by the NPCC to ensure “ride through” capability of the New York State Transmission System. Large Generating Facility response to frequency deviations of predetermined magnitudes, both under-frequency and over-frequency deviations, shall be studied and coordinated with the NYISO and Connecting Transmission Owner in accordance with Good Utility Practice. The term “ride through” as used herein shall mean the ability of a Generating Facility to stay connected to and synchronized with the New York State Transmission System during system disturbances within a range of under-frequency and over-frequency conditions, in accordance with Good Utility Practice and with NPCC Regional Reliability Reference Directory # 12, or its successor.

  • DNS service availability Refers to the ability of the group of listed-­‐as-­‐authoritative name servers of a particular domain name (e.g., a TLD), to answer DNS queries from DNS probes. For the service to be considered available at a particular moment, at least, two of the delegated name servers registered in the DNS must have successful results from “DNS tests” to each of their public-­‐DNS registered “IP addresses” to which the name server resolves. If 51% or more of the DNS testing probes see the service as unavailable during a given time, the DNS service will be considered unavailable.

  • EPP service availability Refers to the ability of the TLD EPP servers as a group, to respond to commands from the Registry accredited Registrars, who already have credentials to the servers. The response shall include appropriate data from the Registry System. An EPP command with “EPP command RTT” 5 times higher than the corresponding SLR will be considered as unanswered. If 51% or more of the EPP testing probes see the EPP service as unavailable during a given time, the EPP service will be considered unavailable.

  • Unbundled Loop Modifications (Line Conditioning 2.5.1 Line Conditioning is defined as routine network modification that BellSouth regularly undertakes to provide xDSL services to its own customers. This may include the removal of any device, from a copper Loop or copper Sub-loop that may diminish the capability of the Loop or Sub-loop to deliver high-speed switched wireline telecommunications capability, including xDSL service. Such devices include, but are not limited to, load coils, excessive bridged taps, low pass filters, and range extenders. Excessive bridged taps are bridged taps that serves no network design purpose and that are beyond the limits set according to industry standards and/or the XxxxXxxxx XX 00000.

Time is Money Join Law Insider Premium to draft better contracts faster.