Volume Corrections for Temperature Sample Clauses

Volume Corrections for Temperature. Except in the case that quantity measurements are made pursuant to the provisions of Article 6.1(c), in which case temperature corrections shall be made in the manner and at the time specified in that Article, temperature readings shall be taken in accordance with the methods listed below in decreasing order of preference, depending on operational conditions prevailing at the Loading Port involved: (a) the flow-weighted average temperature taken at regular times during loading by Seller or its agents at flow meters; and (b) the temperature taken in shore tanks by Seller or its agent. Temperature corrections at 60°F (equivalent to 15.56°C) will then be effected for all volume determinations in accordance with ASTM-1250 or API-MPMS, Chapter 11.1, at Seller’s choice, provided that temperature corrections shall not be made in the case that volume is determined by way of flow meters pursuant to Article 6.1(a) and temperature compensators at 60° F (equivalent to 15.56° C) are integrated into the meter system. S & W, determined in the manner provided in Article 7.1(a), (b) or (c), as the case may be, and Article 7.2, shall be deducted from the volume corrected for temperature as provided above in order to arrive at the volume for purposes of the xxxx of lading and invoice.
AutoNDA by SimpleDocs

Related to Volume Corrections for Temperature

  • Technical Specifications Each Bloom System is an integrated system comprised of a fuel cell stack assembly and associated balance of plant components that converts a fuel into electricity using electrochemical means that (i) has a Nameplate Capacity of at least 0.5 kilowatts of electricity using an electrochemical process and (ii) has an electricity-only generation efficiency greater than thirty percent (30%).

  • Quality Specifications SANMINA-SCI shall comply with the quality specifications set forth in its Quality Manual, incorporated by reference herein, a copy of which is available from SANMINA-SCI upon request.

  • Quality Service Standards/NAV Errors Price Associates and the Fund may, from time to time, agree to certain quality service standards, with respect to the Services hereunder. In the event Price Associates is the party responsible for causing an error in the computation of the net asset value for a Fund or share class of a Fund (“NAV Error”), the actions that are required to be taken as to such NAV Error shall be made in accordance with the Fund’s Net Asset Value Error Correction Policy and Procedures (“NAV Error Policy”) attached hereto as Schedule II.

  • Product Specifications The Company agrees that all Products sold to Xxxx hereunder shall conform to the respective specifications set forth on Schedule A or to such other specifications as are from time to time agreed upon by the Parties.

  • Changes to Specifications All Specifications and any changes thereto agreed to by the parties from time to time shall be in writing, dated and signed by the parties. Any change to the Process shall be deemed a Specification change. No change in the Specifications shall be implemented by Catalent, whether requested by Client or requested or required by any Regulatory Authority, until the parties have agreed in writing to such change, the implementation date of such change, and any increase or decrease in costs, expenses or fees associated with such change (including any change to Unit Pricing). Catalent shall respond promptly to any request made by Client for a change in the Specifications, and both parties shall use commercially reasonable, good faith efforts to agree to the terms of such change in a timely manner. As soon as possible after a request is made for any change in Specifications, Catalent shall notify Client of the costs associated with such change and shall provide such supporting documentation as Client may reasonably require. Client shall pay all costs associated with such agreed upon changes. If there is a conflict between the terms of this Agreement and the terms of the Specifications, this Agreement shall control. Catalent reserves the right to postpone effecting changes to the Specifications until such time as the parties agree to and execute the required written amendment.

  • Cost of Metering The Issuer shall not be obligated to pay any costs associated with the routine metering duties set forth in this Section 2, including the costs of installing, replacing and maintaining meters, nor shall the Issuer be entitled to any credit against the Servicing Fee for any cost savings realized by the Servicer as a result of new metering and/or billing technologies.

  • Quality Service Standards Price Services and the Fund may from time to time agree to certain quality service standards, as well as incentives and penalties with respect to Price Services’ Services hereunder.

  • Quality Standards Each Party agrees that the nature and quality of its products and services supplied in connection with the other Party's Marks will conform to quality standards set by the other Party. Each Party agrees to supply the other Party, upon request, with a reasonable number of samples of any Materials publicly disseminated by such Party which utilize the other Party's Marks. Each Party will comply with all applicable laws, regulations, and customs and obtain any required government approvals pertaining to use of the other Party's marks.

  • Specifications Shipper will ensure that all of its Products tendered at the Origin Point for transportation on the Pipeline System meet the applicable specifications for the Product as set forth in the Tariff (as defined below) (the “Specifications”).

  • API A. Reliant shall supply to Cardinal Health for Manufacturing and Packaging, at Reliant’s sole cost, the API and applicable reference standards in quantities sufficient to meet Reliant’s requirements for each Product as further set forth in Article 4. Prior to delivery of any of the API or reference standard to Cardinal Health for Manufacturing and Packaging, Reliant shall provide to Cardinal Health a copy of the API Material Safety Data Sheet (“MSDS”), as amended, and any subsequent revisions thereto. Reliant shall supply the API, reference standards, and Certificate of Analysis FOB the Facility no later than thirty (30) days before the scheduled Manufacture Date upon which such API will be used by Cardinal Health. Upon receipt of the API, Cardinal Health shall conduct identification testing of the API. Cardinal Health shall use the API solely and exclusively for Manufacturing and Packaging under this Agreement. The maximum volume of API that Reliant supplies to Cardinal Health shall not exceed the amount reflected in the Firm Commitment and the next six (6) months of the Rolling Forecast.

Time is Money Join Law Insider Premium to draft better contracts faster.