WAVEXPRESS INDOOR BTS TECHNICAL DETAILS Sample Clauses

WAVEXPRESS INDOOR BTS TECHNICAL DETAILS. Specifications of the WAVEXpress Indoor BTS hardware are shown in Table 7. ------------------------------------------------------------------------------- Number of TRX per BTS Up to 3 TRX per BTS ------------------------------------------------------------------------------- Tx Frequency Range GSM900: 000 - 000 XXx ------------------------------------------------------------------------------- Rx Frequency Range GSM900: 000 - 000 XXx ------------------------------------------------------------------------------- Channel Spacing 200 KHz ------------------------------------------------------------------------------- Transmitter Output Power Approx. 2 Xxxxx ------------------------------------------------------------------------------- Standards Supported ETSI GSM Phase 2 ------------------------------------------------------------------------------- Features Supported Base station Transceiver Station; GSM RF management, data and fax, short message service, antenna receive diversity, encryption, optional TRX and power supply redundancy, star and daisy chain configuration. ------------------------------------------------------------------------------- Mobile Stations Supported GSM-compliant mobile station (phase 1&2) ------------------------------------------------------------------------------- Mobile Interface GSM full-rate RF interface, 2400 - 9600 bps transparent data and (enhanced full rate capability in Release 5.0). ------------------------------------------------------------------------------- Trunk interface G.703 compliant, E1. ------------------------------------------------------------------------------- Dynamic Power Control 12 dB in 2 dB Step ------------------------------------------------------------------------------- Receiver Sensitivity Typical - 105 dBm ------------------------------------------------------------------------------- Chassis Size 23 cm (width) x 65 cm (height) x 36 cm (depth) ------------------------------------------------------------------------------- Weight Approx. 20 kg ------------------------------------------------------------------------------- Volume 81.9 liters ------------------------------------------------------------------------------- Operating Temperature 0 (0)C to + 45 (0)C ------------------------------------------------------------------------------- Humidity 10 % to 90 % non-condensing ------------------------------------------------------------------------------- Thermal Shock IEC 68-2-14 --------------...
AutoNDA by SimpleDocs

Related to WAVEXPRESS INDOOR BTS TECHNICAL DETAILS

  • Manufacturing Technology Transfer With respect to each Technology Transfer Product, upon AbbVie’s written request after the Inclusion Date for the Included Target to which such Technology Transfer Product is Directed, Morphic shall effect a full transfer to AbbVie or its designee (which designee may be an Affiliate or a Third Party manufacturer) of all Morphic Know-How and Joint Know-How relating to the then-current process for the Manufacture of such Technology Transfer Product (the “Manufacturing Process”) and to implement the Manufacturing Process at facilities designated by AbbVie (such transfer and implementation, as more fully described in this Section 5.3, the “Manufacturing Technology Transfer”). To assist with the Manufacturing Technology Transfer, Morphic will make its personnel reasonably available to AbbVie during normal business hours for up to [***] FTE hours with respect to each Included Target (in each case, free of charge to AbbVie) to transfer and implement the Manufacturing Process under this Section 5.3. Thereafter, if requested by AbbVie, Morphic shall continue to perform such obligations; provided, that AbbVie will reimburse Morphic for its full-time equivalent (FTE) costs (for clarity, in excess of [***] FTE hours) and any reasonable and verifiable out-of-pocket costs incurred in providing such assistance. CERTAIN CONFIDENTIAL INFORMATION CONTAINED IN THIS DOCUMENT, MARKED BY [***], HAS BEEN OMITTED BECAUSE IT IS NOT MATERIAL AND WOULD LIKELY CAUSE COMPETITIVE HARM TO THE COMPANY IF PUBLICLY DISCLOSED.

  • Third Party Software Customer acknowledges that in order for MyEcheck to perform the Consulting Services, Customer may need to obtain additional third party services ("Third Party Services") or third party technology ("Third Party Technology"). Customer agrees that the rights and licenses with respect to Third Party Technology and Third Party Services shall be under terms set forth in the pertinent purchase, license or services agreements between Customer and the vendors of such Third Party Software or Third Party Services. Customer shall execute and comply with appropriate purchase, license, or services agreements with respect to any Third Party Software or Third Party Services. Any amounts payable to third party vendors or service providers under such agreements are the sole responsibility of Customer and shall be paid directly by Customer to such third party vendors or service providers. MyEcheck Services Agreement

  • Third Party Technology The assignment of any applicable license agreements with respect to Third Party Technology are set forth in the General Assignment and Assumption Agreement.

  • Clinical Data The descriptions of the results of any studies and tests conducted by or on behalf of, or sponsored by, the Company or its subsidiaries, or in which the Company has participated, that are described in the Disclosure Package and the Prospectus, or the results of which are referred to in the Disclosure Package and the Prospectus do not contain any misstatement of material fact or omit to state a material fact necessary to make such statements not misleading. The Company has no knowledge of any studies or tests not described in the Disclosure Package and the Prospectus the results of which reasonably call into question in any material respect the results of the studies, tests and trials described in the Disclosure Package or Prospectus.

  • Know-How The term “

  • Tests and Preclinical and Clinical Trials The preclinical studies and clinical trials conducted by or, to the Company’s knowledge, on behalf of the Company, that are described in the Registration Statement, the Pricing Disclosure Package and the Prospectus, as applicable, and are intended to be submitted to the U.S. Food and Drug Administration (the “FDA”) or other comparable government entities, were and, if still ongoing, are being conducted in all material respects in accordance with experimental protocols, procedures and controls pursuant to accepted professional scientific standards and all Authorizations and Applicable Laws, including, without limitation, current Good Clinical Practices and Good Laboratory Practices and any applicable rules and regulations of the jurisdiction in which such trials and studies are being conducted; the descriptions of the results of such studies and trials contained in the Registration Statement, the Pricing Disclosure Package and the Prospectus are, to the Company’s knowledge, accurate and complete in all material respects and fairly present the data derived from such studies and trials; except to the extent disclosed in the Registration Statement, the Pricing Disclosure Package and the Prospectus, the Company is not aware of any studies or trials, the results of which the Company believes reasonably call into question the study or trial results described or referred to in the Registration Statement, the Pricing Disclosure Package and the Prospectus when viewed in the context in which such results are described and the clinical stage of development; and, except to the extent disclosed in the Registration Statement, the Pricing Disclosure Package or the Prospectus, the Company has not received any written notices or written correspondence from the FDA or any governmental entity requiring the termination or suspension of any preclinical studies or clinical trials conducted by or on behalf of the Company, other than ordinary course communications with respect to modifications in connection with the design and implementation of such trials, copies of which communications have been made available to you.

  • Commercialization License Subject to the terms of this Agreement, including without limitation Section 2.2 and Theravance's Co-Promotion rights in Section 5.3.2, Theravance hereby grants to GSK, and GSK accepts, an exclusive license under the Theravance Patents and Theravance Know-How to make, have made, use, sell, offer for sale and import Alliance Products in the Territory.

  • Background Technology List here prior contracts to assign Inventions that are now in existence between any other person or entity and you. [ ] List here previous Inventions which you desire to have specifically excluded from the operation of this Agreement. Continue on reverse side if necessary.

  • USE OF THIRD PARTY SYSTEMS-LEVEL SOFTWARE State Street and the Fund acknowledge that in connection with the Data Access Services provided under this Addendum, the Fund will have access, through the Data Access Services, to Fund Data and to functions of State Street’s proprietary systems; provided, however that in no event will the Fund have direct access to any third party systems-level software that retrieves data for, stores data from, or otherwise supports the System.

  • Licensed Technology The term "Licensed Technology" shall mean the ------------------- Licensed Patents, plus all improvements thereto developed by Licensor, and all related data, know-how and technology.

Time is Money Join Law Insider Premium to draft better contracts faster.