Power Consumption Sample Clauses

Power Consumption. Based on minimum 7 watts per square foot (exclusive of HVAC equipment) of which 2 wxxxx are at 120/208 volt and 3.5 watts allocated for lighting. Xxxxxption for cubicle installatiox xx 5 watts per 6 x 8 cubicle. LPT Standard Specifications
AutoNDA by SimpleDocs
Power Consumption. Hotel shall provide at its sole cost electric power ----------------- supply suitable for the Service including recurring monthly charges to a maximum of Fifty Cents ($50/100) per installed guest and meeting rooms per month ($6.00 annual). Hotel reserves the right to charge Licensee for electrical usage in excess of such amount.
Power Consumption. System consumes the maximum power @ 65°C with full traffic loading & all FAN runs at max. 25000RPM. The actual system power consumption will be calculated based on Beta verification data. Per system power estimation data, the switch board power consumption is around 240W with below configuration: timing interface & BMC works normally, 28x port SFP+ loopbacks with 1.5W power, 2x port QSFP28 loopback with 3.5W power, 6x DDR4 SDRAM packet buffer enabled, MAC & 10G,100G PHY runs at 300Gpbs traffic switching/forwarding, 5x FAN modules runs at 25000RPM. Measurement of existing Xxxxxxxxx-DE CPU (4-core/2.2GHz) with 16GB SODIMM and 128GB SSD is 60W max. System total power consumption: 240 + 60W = Max. 300W To consider PSU efficiency 90% from -48V to +12V, overall system power requirement will be 300 / 0.9 = 333.3W. 2.3.1 Thermal Monitoring
Power Consumption. The following tables list details of the power dissipation, weight, FITS and size for the TN-4XE equipment. TABLE 8-1 SUBRACK KEY SPECIFICATION DETAILS
Power Consumption. The fidelity in modelling power consumption may vary. The average power regardless of mode could be represented (1), or the different power levels in each mode (2), or a varying power within each mode (3). Establishing the total power or energy consumption over an interval of time would then be treated differently in each case. Alternative 1) would mean that the genericConstraintValue over all GenericConstraints with Alternative 2) would mean that each unique mode assignment for the integrated architecture is traversed, and the genericConstraintValue over all GenericConstraints with genericConstraintType powerConsumption are multiplied by the time spent in this mode and added. Alternative 3) would mean that simulation or analytical means are used to establish the instantaneous power in each component. Because power is allowed to vary, the component power must be defined by a function. Typically, power is related to the nominal functional behaviour of the component. The genericConstraintValue for a powerConstraint could thus be an expression with nominal signals as operands. This is however not supported by EAST-ADL. The instant view of the power consumption can be used for integrating to energy consumption, averaging power levels for certain intervals, finding peak values, etc.
Power Consumption. 51 12.3 Timing...................................................................................................52 12.3.1
Power Consumption. A.9.01 Central computing environment
AutoNDA by SimpleDocs
Power Consumption. Any additional equipment the Agency wishes to add to the rack(s) in their area is to be evaluated by DAS OIT for power and cooling requirements (and the possible need for additional UPS or wiring requirements) prior to the addition of the equipment. DAS OIT will attempt to fulfill the Agency requests for power within the limits of the SOCC and the PDUs that serve the Agency. Should additional PDU(s) be required to serve the Agency, there may be a brief, mutually agreeable period provided to allow DAS OIT to relocate additional PDU(s) to serve the Agency needs. Each Agency rack has a breaker rate limit (e.g. 20 amps, 30 amps, 50 amps). It is the responsibility of the Agency to ensure that equipment in their rack is below the appropriate breaker limit. DAS OIT requires the use of “Smart” Power Distribution Units (PDUs) so that the Agency can meter and better manage their power consumption.
Power Consumption. Equally important is the power consumption of the Green Box, especially when the car’s engine is switched off. This is for the following reasons • The risk of completely discharging the battery • In BMW cars and on some models of Audi, the on-board car computer switches off the electrical supply in the car, if it detects power consumption by electrical systems in the car greater than 10mA when the engine is turned off. Therefore, the Green Box design should consider this restriction on the power consumption to work on those models. As from 2013, with the uptake of electrical vehicles, these issues will become more salient and have to be addressed. In addition, it is currently unclear what will be the state (live or off) of the electrical system of such cars during the charging phase of the car batteries.
Power Consumption. Liquidated damages of $1,370 per kW shall apply for every kW in excess of the guaranteed power consumption (excluding fan).