Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.
Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.
Major Decisions (A) Subject to Sections 7.3(C) and 7.3(D) with respect to the Company, all major decisions of the Company set forth below in clauses (A)(1) through (A)(6) (“Major Decisions”) shall be subject to the Company’s Articles of Incorporation and joint approval by the Advisor and Sub-advisor. For the avoidance of doubt, Major Decisions specifically exclude any decisions regarding the day-to-day operations of the Company, the decision-making authority for which has been delegated to the Sub-advisor pursuant to this Agreement. Major Decisions shall consist of the following: (1) Decisions to recommend to the Board of Directors that the Company acquire or sell Properties, Loans and other Permitted Investments; (2) Retention of investment banks for the Company; (3) Marketing methods for the Company’s sale of Shares; (4) Extending, initiating or terminating the Initial Public Offering or any subsequent Offering of the Shares; (5) Issuing press releases involving the major decisions of the Company or the Advisor or Sub-advisor or their Affiliates with respect to the business or operations of the Company; provided, that the Sub-advisor need not obtain consent to any press releases regarding acquisitions or dispositions of Properties, Loans or other Permitted Investments; and provided further, however, that notwithstanding the immediately preceding proviso, any mention of the Advisor or its Affiliates in such press releases regarding acquisitions or dispositions shall be pre-approved by the Advisor; and (6) Merging or otherwise engaging in any change of control transaction for the Company. (B) Notwithstanding anything in this Agreement to the contrary, if the Parties do not agree to any action constituting a Major Decision that is described in any of clauses (A)(2) through (A)(6) above and that has been proposed by either Party, the Parties shall meet (in person or by phone) to discuss the issue in dispute in good faith over the five-business day period beginning with the delivery of notice of the proposed action to the other Party. (C) Notwithstanding anything in this Agreement to the contrary, with respect to Major Decisions described in clause (A)(1) above (but subject to Section 7.3(D)), (1) joint approval shall not be required, (2) the Sub-advisor and the Advisor shall discuss the proposed transaction (either in person or by phone) prior to either Party making any recommendation of the proposed transaction to the Board of Directors, and (3) the Sub-Advisor and the Advisor shall each give due consideration to the opinions of the other Party. Ordinarily, such discussions shall begin at least five business days before a recommendation is made to the Board of Directors; however, if in the sole discretion of the Sub-advisor it is in the best interest of the Company to make a recommendation to the Board of Directors more promptly, then the Sub-advisor may do so. In the event the Parties do not agree as to whether to recommend the proposed transaction to the Board of Directors, the Sub-advisor’s decision shall govern. (D) Notwithstanding the provisions of this Section 7.3 or any other provision in this Agreement to the contrary, in all events, including Major Decisions, the Company will be managed under the direction of the Board of Directors. (E) Notwithstanding anything in this Agreement to the contrary (but subject to Section 7.3(D)), the Sub-advisor shall have sole authority to act on behalf of the Company regarding amending the Advisory Agreement.
Technical Advisory Committee (TAC The goal of this subtask is to create an advisory committee for this Agreement. The TAC should be composed of diverse professionals. The composition will vary depending on interest, availability, and need. TAC members will serve at the CAM’s discretion. The purpose of the TAC is to: • Provide guidance in project direction. The guidance may include scope and methodologies, timing, and coordination with other projects. The guidance may be based on: o Technical area expertise; o Knowledge of market applications; or o Linkages between the agreement work and other past, present, or future projects (both public and private sectors) that TAC members are aware of in a particular area. • Review products and provide recommendations for needed product adjustments, refinements, or enhancements. • Evaluate the tangible benefits of the project to the state of California, and provide recommendations as needed to enhance the benefits. • Provide recommendations regarding information dissemination, market pathways, or commercialization strategies relevant to the project products. The TAC may be composed of qualified professionals spanning the following types of disciplines: • Researchers knowledgeable about the project subject matter; • Members of trades that will apply the results of the project (e.g., designers, engineers, architects, contractors, and trade representatives); • Public interest market transformation implementers; • Product developers relevant to the project; • U.S. Department of Energy research managers, or experts from other federal or state agencies relevant to the project; • Public interest environmental groups; • Utility representatives; • Air district staff; and • Members of relevant technical society committees. • Prepare a List of Potential TAC Members that includes the names, companies, physical and electronic addresses, and phone numbers of potential members. The list will be discussed at the Kick-off meeting, and a schedule for recruiting members and holding the first TAC meeting will be developed. • Recruit TAC members. Ensure that each individual understands member obligations and the TAC meeting schedule developed in subtask 1.11. • Prepare a List of TAC Members once all TAC members have committed to serving on the TAC. • Submit Documentation of TAC Member Commitment (such as Letters of Acceptance) from each TAC member. • List of Potential TAC Members • List of TAC Members • Documentation of TAC Member Commitment
Peer Review Dental Group, after consultation with the Joint ----------- Operations Committee, shall implement, regularly review, modify as necessary or appropriate and obtain the commitment of Providers to actively participate in peer review procedures for Providers. Dental Group shall assist Manager in the production of periodic reports describing the results of such procedures. Dental Group shall provide Manager with prompt notice of any information that raises a reasonable risk to the health and safety of Group Patients or Beneficiaries. In any event, after consultation with the Joint Operations Committee, Dental Group shall take such action as may be reasonably warranted under the facts and circumstances.
Proposed Corrective Action Plan Simultaneously with the submission of the Audit, the Recipient will submit to OCR for its review and approval a proposed Corrective Action Plan to address all inaccessible content and functionality identified during the Recipient’s Audit. The proposed Corrective Action Plan will set out a detailed schedule for: (1) addressing problems, taking into account identified priorities, with all corrective actions to be completed within 18 months of the date OCR approved the Corrective Action Plan; (2) setting up systems of accountability and verifying claims of accessibility by vendors or open sources; and setting up a system of testing and accountability to maintain the accessibility of all online content and functionality on an ongoing basis.
Initial Decision Maker The Architect will serve as the Initial Decision Maker pursuant to Article 15 of AIA Document A201–2017, unless the parties appoint below another individual, not a party to this Agreement, to serve as the Initial Decision Maker.
SITE-BASED DECISION MAKING A. The District shall provide the training and staff development to support accountability/site- based decision-making activities. Teachers shall be given release time to attend these programs. B. Participation on the SAC shall not serve as a basis for the evaluation of any teacher. C. A minimum of three (3) to a maximum of five (5) teachers from each school shall serve on their school’s budget advisory committee formed for the purpose of making recommendations on the school’s general fund budget. Teacher members shall be elected by the faculty. Minutes from such meetings may be requested by the faculty and may be posted on the CTA bulletin board at the school by the Association Representative.
Claims Review Methodology a. C laims Review Population. A description of the Population subject to the Quarterly Claims Review.
Emergency/Declared Disaster Requirements In the event of an emergency or if Orange County is declared a disaster area by the County, state or federal government, this Contract may be subjected to unusual usage. The Contractor shall service the County during such an emergency or declared disaster under the same terms and conditions that apply during non-emergency/disaster conditions. The pricing quoted by the Contractor shall apply to serving the County’s needs regardless of the circumstances. If the Contractor is unable to supply the goods/services under the terms of the Contract, then the Contractor shall provide proof of such disruption and a copy of the invoice for the goods/services from the Contractor’s supplier(s). Additional profit margin as a result of supplying goods/services during an emergency or a declared disaster shall not be permitted. In the event of an emergency or declared disaster, emergency purchase order numbers will be assigned. All applicable invoices from the Contractor shall show both the emergency purchase order number and the Contract number.